Loading…

Influence of voltage dips on industrial equipment: Analysis and assessment

► We perform more than 6000 tests over several industrial equipments under voltage dips. ► Different magnitude, duration and point-on-wave initiation are taken into account. ► Working temperature varies the voltage-tolerance curve of some industrial equipments. ► Scatter bands have been identified a...

Full description

Saved in:
Bibliographic Details
Published in:International journal of electrical power & energy systems 2012-10, Vol.41 (1), p.87-95
Main Authors: Honrubia-Escribano, A., Gómez-Lázaro, E., Molina-García, A., Fuentes, J.A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c369t-19bdecb060fcbdf52941299d28ae7a0a162d927c647cd7c8b9ee1d3129b616133
cites cdi_FETCH-LOGICAL-c369t-19bdecb060fcbdf52941299d28ae7a0a162d927c647cd7c8b9ee1d3129b616133
container_end_page 95
container_issue 1
container_start_page 87
container_title International journal of electrical power & energy systems
container_volume 41
creator Honrubia-Escribano, A.
Gómez-Lázaro, E.
Molina-García, A.
Fuentes, J.A.
description ► We perform more than 6000 tests over several industrial equipments under voltage dips. ► Different magnitude, duration and point-on-wave initiation are taken into account. ► Working temperature varies the voltage-tolerance curve of some industrial equipments. ► Scatter bands have been identified according to a failure probability function. This paper presents a study of industry equipment electrical responses under voltage dips with different magnitude, duration and point-on-wave initiation. The analysis provides electrical sensitive curves for safe and reliable operation based on experimental tests performed over real AC-contactors, ground fault relays, variable speed drives, industrial computers and lighting loads. The presence of a relevant scatter-band where the sensitivity of some equipments in the presence voltage dips responds in a stochastic manner is analysed. The effect of the working temperature of the device is studied as well. A detailed description of the testing procedure is provided, proposing additional voltage dip parameters to characterize the equipment sensitivity in detail. In this way, existing standards and previously published contributions are reviewed and compared with the obtained results. The obtained results are useful for OEMs, Utilities as well as Uninterruptible Power Supply Manufacturers; where a more precise counting of equipment failures due to voltage dips is essential for an economic and technical assessment of power quality.
doi_str_mv 10.1016/j.ijepes.2012.03.018
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1034822136</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0142061512000737</els_id><sourcerecordid>1034822136</sourcerecordid><originalsourceid>FETCH-LOGICAL-c369t-19bdecb060fcbdf52941299d28ae7a0a162d927c647cd7c8b9ee1d3129b616133</originalsourceid><addsrcrecordid>eNp9kE1r3DAQhkVpoNu0_6AHXQq92NVItmz1UAghH1sWeknOQpbGRYtXdjT2wv77eNnQY05zmOedl3kY-waiBAH6576Me5yQSilAlkKVAtoPbANtYwpVQ_ORbQRUshAa6k_sM9FeCNGYSm7Yn23qhwWTRz72_DgOs_uHPMSJ-Jh4TGGhOUc3cHxZ4nTANP_iN8kNJ4rEXQrcESHRefGFXfVuIPz6Nq_Z8_3d0-1jsfv7sL292RVeaTMXYLqAvhNa9L4LfS1NBdKYIFuHjRMOtAxGNl5XjQ-NbzuDCEGtTKdBg1LX7Mfl7pTHlwVptodIHofBJRwXsiBU1UoJSq9odUF9Hoky9nbK8eDyaYXsWZ3d24s6e1ZnhbKrujX2_a3BkXdDn13ykf5nZW1kq3W9cr8vHK7vHiNmSz6eXYaY0c82jPH9olfznYat</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1034822136</pqid></control><display><type>article</type><title>Influence of voltage dips on industrial equipment: Analysis and assessment</title><source>Elsevier</source><creator>Honrubia-Escribano, A. ; Gómez-Lázaro, E. ; Molina-García, A. ; Fuentes, J.A.</creator><creatorcontrib>Honrubia-Escribano, A. ; Gómez-Lázaro, E. ; Molina-García, A. ; Fuentes, J.A.</creatorcontrib><description>► We perform more than 6000 tests over several industrial equipments under voltage dips. ► Different magnitude, duration and point-on-wave initiation are taken into account. ► Working temperature varies the voltage-tolerance curve of some industrial equipments. ► Scatter bands have been identified according to a failure probability function. This paper presents a study of industry equipment electrical responses under voltage dips with different magnitude, duration and point-on-wave initiation. The analysis provides electrical sensitive curves for safe and reliable operation based on experimental tests performed over real AC-contactors, ground fault relays, variable speed drives, industrial computers and lighting loads. The presence of a relevant scatter-band where the sensitivity of some equipments in the presence voltage dips responds in a stochastic manner is analysed. The effect of the working temperature of the device is studied as well. A detailed description of the testing procedure is provided, proposing additional voltage dip parameters to characterize the equipment sensitivity in detail. In this way, existing standards and previously published contributions are reviewed and compared with the obtained results. The obtained results are useful for OEMs, Utilities as well as Uninterruptible Power Supply Manufacturers; where a more precise counting of equipment failures due to voltage dips is essential for an economic and technical assessment of power quality.</description><identifier>ISSN: 0142-0615</identifier><identifier>EISSN: 1879-3517</identifier><identifier>DOI: 10.1016/j.ijepes.2012.03.018</identifier><identifier>CODEN: IEPSDC</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Applied sciences ; Connection and protection apparatus ; Electrical engineering. Electrical power engineering ; Electrical machines ; Exact sciences and technology ; Industrial equipment ; Miscellaneous ; Power electronics, power supplies ; Power quality ; Power system reliability ; Regulation and control ; Various equipment and components ; Voltage dips</subject><ispartof>International journal of electrical power &amp; energy systems, 2012-10, Vol.41 (1), p.87-95</ispartof><rights>2012 Elsevier Ltd</rights><rights>2015 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c369t-19bdecb060fcbdf52941299d28ae7a0a162d927c647cd7c8b9ee1d3129b616133</citedby><cites>FETCH-LOGICAL-c369t-19bdecb060fcbdf52941299d28ae7a0a162d927c647cd7c8b9ee1d3129b616133</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=25928665$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Honrubia-Escribano, A.</creatorcontrib><creatorcontrib>Gómez-Lázaro, E.</creatorcontrib><creatorcontrib>Molina-García, A.</creatorcontrib><creatorcontrib>Fuentes, J.A.</creatorcontrib><title>Influence of voltage dips on industrial equipment: Analysis and assessment</title><title>International journal of electrical power &amp; energy systems</title><description>► We perform more than 6000 tests over several industrial equipments under voltage dips. ► Different magnitude, duration and point-on-wave initiation are taken into account. ► Working temperature varies the voltage-tolerance curve of some industrial equipments. ► Scatter bands have been identified according to a failure probability function. This paper presents a study of industry equipment electrical responses under voltage dips with different magnitude, duration and point-on-wave initiation. The analysis provides electrical sensitive curves for safe and reliable operation based on experimental tests performed over real AC-contactors, ground fault relays, variable speed drives, industrial computers and lighting loads. The presence of a relevant scatter-band where the sensitivity of some equipments in the presence voltage dips responds in a stochastic manner is analysed. The effect of the working temperature of the device is studied as well. A detailed description of the testing procedure is provided, proposing additional voltage dip parameters to characterize the equipment sensitivity in detail. In this way, existing standards and previously published contributions are reviewed and compared with the obtained results. The obtained results are useful for OEMs, Utilities as well as Uninterruptible Power Supply Manufacturers; where a more precise counting of equipment failures due to voltage dips is essential for an economic and technical assessment of power quality.</description><subject>Applied sciences</subject><subject>Connection and protection apparatus</subject><subject>Electrical engineering. Electrical power engineering</subject><subject>Electrical machines</subject><subject>Exact sciences and technology</subject><subject>Industrial equipment</subject><subject>Miscellaneous</subject><subject>Power electronics, power supplies</subject><subject>Power quality</subject><subject>Power system reliability</subject><subject>Regulation and control</subject><subject>Various equipment and components</subject><subject>Voltage dips</subject><issn>0142-0615</issn><issn>1879-3517</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNp9kE1r3DAQhkVpoNu0_6AHXQq92NVItmz1UAghH1sWeknOQpbGRYtXdjT2wv77eNnQY05zmOedl3kY-waiBAH6576Me5yQSilAlkKVAtoPbANtYwpVQ_ORbQRUshAa6k_sM9FeCNGYSm7Yn23qhwWTRz72_DgOs_uHPMSJ-Jh4TGGhOUc3cHxZ4nTANP_iN8kNJ4rEXQrcESHRefGFXfVuIPz6Nq_Z8_3d0-1jsfv7sL292RVeaTMXYLqAvhNa9L4LfS1NBdKYIFuHjRMOtAxGNl5XjQ-NbzuDCEGtTKdBg1LX7Mfl7pTHlwVptodIHofBJRwXsiBU1UoJSq9odUF9Hoky9nbK8eDyaYXsWZ3d24s6e1ZnhbKrujX2_a3BkXdDn13ykf5nZW1kq3W9cr8vHK7vHiNmSz6eXYaY0c82jPH9olfznYat</recordid><startdate>20121001</startdate><enddate>20121001</enddate><creator>Honrubia-Escribano, A.</creator><creator>Gómez-Lázaro, E.</creator><creator>Molina-García, A.</creator><creator>Fuentes, J.A.</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope></search><sort><creationdate>20121001</creationdate><title>Influence of voltage dips on industrial equipment: Analysis and assessment</title><author>Honrubia-Escribano, A. ; Gómez-Lázaro, E. ; Molina-García, A. ; Fuentes, J.A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c369t-19bdecb060fcbdf52941299d28ae7a0a162d927c647cd7c8b9ee1d3129b616133</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Applied sciences</topic><topic>Connection and protection apparatus</topic><topic>Electrical engineering. Electrical power engineering</topic><topic>Electrical machines</topic><topic>Exact sciences and technology</topic><topic>Industrial equipment</topic><topic>Miscellaneous</topic><topic>Power electronics, power supplies</topic><topic>Power quality</topic><topic>Power system reliability</topic><topic>Regulation and control</topic><topic>Various equipment and components</topic><topic>Voltage dips</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Honrubia-Escribano, A.</creatorcontrib><creatorcontrib>Gómez-Lázaro, E.</creatorcontrib><creatorcontrib>Molina-García, A.</creatorcontrib><creatorcontrib>Fuentes, J.A.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><jtitle>International journal of electrical power &amp; energy systems</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Honrubia-Escribano, A.</au><au>Gómez-Lázaro, E.</au><au>Molina-García, A.</au><au>Fuentes, J.A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Influence of voltage dips on industrial equipment: Analysis and assessment</atitle><jtitle>International journal of electrical power &amp; energy systems</jtitle><date>2012-10-01</date><risdate>2012</risdate><volume>41</volume><issue>1</issue><spage>87</spage><epage>95</epage><pages>87-95</pages><issn>0142-0615</issn><eissn>1879-3517</eissn><coden>IEPSDC</coden><abstract>► We perform more than 6000 tests over several industrial equipments under voltage dips. ► Different magnitude, duration and point-on-wave initiation are taken into account. ► Working temperature varies the voltage-tolerance curve of some industrial equipments. ► Scatter bands have been identified according to a failure probability function. This paper presents a study of industry equipment electrical responses under voltage dips with different magnitude, duration and point-on-wave initiation. The analysis provides electrical sensitive curves for safe and reliable operation based on experimental tests performed over real AC-contactors, ground fault relays, variable speed drives, industrial computers and lighting loads. The presence of a relevant scatter-band where the sensitivity of some equipments in the presence voltage dips responds in a stochastic manner is analysed. The effect of the working temperature of the device is studied as well. A detailed description of the testing procedure is provided, proposing additional voltage dip parameters to characterize the equipment sensitivity in detail. In this way, existing standards and previously published contributions are reviewed and compared with the obtained results. The obtained results are useful for OEMs, Utilities as well as Uninterruptible Power Supply Manufacturers; where a more precise counting of equipment failures due to voltage dips is essential for an economic and technical assessment of power quality.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.ijepes.2012.03.018</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0142-0615
ispartof International journal of electrical power & energy systems, 2012-10, Vol.41 (1), p.87-95
issn 0142-0615
1879-3517
language eng
recordid cdi_proquest_miscellaneous_1034822136
source Elsevier
subjects Applied sciences
Connection and protection apparatus
Electrical engineering. Electrical power engineering
Electrical machines
Exact sciences and technology
Industrial equipment
Miscellaneous
Power electronics, power supplies
Power quality
Power system reliability
Regulation and control
Various equipment and components
Voltage dips
title Influence of voltage dips on industrial equipment: Analysis and assessment
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T20%3A53%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Influence%20of%20voltage%20dips%20on%20industrial%20equipment:%20Analysis%20and%20assessment&rft.jtitle=International%20journal%20of%20electrical%20power%20&%20energy%20systems&rft.au=Honrubia-Escribano,%20A.&rft.date=2012-10-01&rft.volume=41&rft.issue=1&rft.spage=87&rft.epage=95&rft.pages=87-95&rft.issn=0142-0615&rft.eissn=1879-3517&rft.coden=IEPSDC&rft_id=info:doi/10.1016/j.ijepes.2012.03.018&rft_dat=%3Cproquest_cross%3E1034822136%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c369t-19bdecb060fcbdf52941299d28ae7a0a162d927c647cd7c8b9ee1d3129b616133%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1034822136&rft_id=info:pmid/&rfr_iscdi=true