Loading…
Comparison between the Efficiencies of sub-2 μm C18 Particles Packed in Narrow Bore Columns
The chromatographic performance of two types of core−shell particles and two fully porous particles packed in 2.1 ID × 50 mm columns was investigated. Comparisons of the performances of the EiS-150-C18 to that of the Kinetex-1.7 μm-C18, Acquity-BEH-1.7 μm-C18, and Zorbax-XDB-1.8 μm-C18 are made and...
Saved in:
Published in: | Analytical chemistry (Washington) 2011-03, Vol.83 (5), p.1547-1556 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 1556 |
container_issue | 5 |
container_start_page | 1547 |
container_title | Analytical chemistry (Washington) |
container_volume | 83 |
creator | Omamogho, Jesse O Glennon, Jeremy D |
description | The chromatographic performance of two types of core−shell particles and two fully porous particles packed in 2.1 ID × 50 mm columns was investigated. Comparisons of the performances of the EiS-150-C18 to that of the Kinetex-1.7 μm-C18, Acquity-BEH-1.7 μm-C18, and Zorbax-XDB-1.8 μm-C18 are made and discussed. The physical factors that govern the performance of these columns, such as particle size distribution and column external, total, and particle porosity of the C18 packing materials were among the prime foci of investigation. The differences in the mass transfer behavior measured using naphtho[2,3-a]pyrene between these columns provides an indication of improved performance of the new EiS-150-C18 column. The minimum reduced height equivalent to a theoretical plate (HETP) value for the EiS-150-C18, h min = 1.95, was achieved and was comparable to that obtained from the C18 phases of the Kinetex (h min = 2.53), the Acquity (h min = 2.26), and the Zorbax (h min = 2.57) columns. This study reveals the importance of the dimension of the shell thickness in controlling the performance of columns packed with shell particles in narrow bore columns. |
doi_str_mv | 10.1021/ac102139a |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_1115530205</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1115530205</sourcerecordid><originalsourceid>FETCH-LOGICAL-a271t-46f5b85a7805d8e910904b0d30c4999352f6ce9baaad3078ae0fdb6f2207e2073</originalsourceid><addsrcrecordid>eNpFkc9Kw0AQxhdRbK0efAHZi-AlOrPp5s9RQ_0DRXvQmxAmm11MTbJ1N6H4bj6Dz2SqVQ8fAzM_ZpjvY-wY4RxB4AWpTQlT2mFjlAKCKEnELhsDQBiIGGDEDrxfAiACRvtsJFCkiLEcs-fMNitylbctL3S31rrl3YvmM2MqVel2kOfWcN8XgeCfHw3PMOELcl2l6mG0IPWqS161_J6cs2t-ZZ3mma37pvWHbM9Q7fXRtk7Y0_XsMbsN5g83d9nlPCARYxdMIyOLRFKcgCwTnSKkMC2gDEFN0zQNpTCR0mlBREMvTkiDKYvICAGxHhRO2NnP3pWzb732Xd5UXum6plbb3ueIKGUIAuSAnmzRvmh0ma9c1ZB7z38dGYDTLUBeUW0cDR74f24aiij-vrnlSPl8aXvXDh_mCPkmivwvkfAL3bp4-w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1115530205</pqid></control><display><type>article</type><title>Comparison between the Efficiencies of sub-2 μm C18 Particles Packed in Narrow Bore Columns</title><source>American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list)</source><creator>Omamogho, Jesse O ; Glennon, Jeremy D</creator><creatorcontrib>Omamogho, Jesse O ; Glennon, Jeremy D</creatorcontrib><description>The chromatographic performance of two types of core−shell particles and two fully porous particles packed in 2.1 ID × 50 mm columns was investigated. Comparisons of the performances of the EiS-150-C18 to that of the Kinetex-1.7 μm-C18, Acquity-BEH-1.7 μm-C18, and Zorbax-XDB-1.8 μm-C18 are made and discussed. The physical factors that govern the performance of these columns, such as particle size distribution and column external, total, and particle porosity of the C18 packing materials were among the prime foci of investigation. The differences in the mass transfer behavior measured using naphtho[2,3-a]pyrene between these columns provides an indication of improved performance of the new EiS-150-C18 column. The minimum reduced height equivalent to a theoretical plate (HETP) value for the EiS-150-C18, h min = 1.95, was achieved and was comparable to that obtained from the C18 phases of the Kinetex (h min = 2.53), the Acquity (h min = 2.26), and the Zorbax (h min = 2.57) columns. This study reveals the importance of the dimension of the shell thickness in controlling the performance of columns packed with shell particles in narrow bore columns.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/ac102139a</identifier><identifier>PMID: 21291175</identifier><identifier>CODEN: ANCHAM</identifier><language>eng</language><publisher>Washington, DC: American Chemical Society</publisher><subject>Analytical chemistry ; Chemistry ; Chromatographic methods and physical methods associated with chromatography ; Exact sciences and technology ; Other chromatographic methods</subject><ispartof>Analytical chemistry (Washington), 2011-03, Vol.83 (5), p.1547-1556</ispartof><rights>Copyright © 2011 American Chemical Society</rights><rights>2015 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=24326707$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21291175$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Omamogho, Jesse O</creatorcontrib><creatorcontrib>Glennon, Jeremy D</creatorcontrib><title>Comparison between the Efficiencies of sub-2 μm C18 Particles Packed in Narrow Bore Columns</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>The chromatographic performance of two types of core−shell particles and two fully porous particles packed in 2.1 ID × 50 mm columns was investigated. Comparisons of the performances of the EiS-150-C18 to that of the Kinetex-1.7 μm-C18, Acquity-BEH-1.7 μm-C18, and Zorbax-XDB-1.8 μm-C18 are made and discussed. The physical factors that govern the performance of these columns, such as particle size distribution and column external, total, and particle porosity of the C18 packing materials were among the prime foci of investigation. The differences in the mass transfer behavior measured using naphtho[2,3-a]pyrene between these columns provides an indication of improved performance of the new EiS-150-C18 column. The minimum reduced height equivalent to a theoretical plate (HETP) value for the EiS-150-C18, h min = 1.95, was achieved and was comparable to that obtained from the C18 phases of the Kinetex (h min = 2.53), the Acquity (h min = 2.26), and the Zorbax (h min = 2.57) columns. This study reveals the importance of the dimension of the shell thickness in controlling the performance of columns packed with shell particles in narrow bore columns.</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>Chromatographic methods and physical methods associated with chromatography</subject><subject>Exact sciences and technology</subject><subject>Other chromatographic methods</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNpFkc9Kw0AQxhdRbK0efAHZi-AlOrPp5s9RQ_0DRXvQmxAmm11MTbJ1N6H4bj6Dz2SqVQ8fAzM_ZpjvY-wY4RxB4AWpTQlT2mFjlAKCKEnELhsDQBiIGGDEDrxfAiACRvtsJFCkiLEcs-fMNitylbctL3S31rrl3YvmM2MqVel2kOfWcN8XgeCfHw3PMOELcl2l6mG0IPWqS161_J6cs2t-ZZ3mma37pvWHbM9Q7fXRtk7Y0_XsMbsN5g83d9nlPCARYxdMIyOLRFKcgCwTnSKkMC2gDEFN0zQNpTCR0mlBREMvTkiDKYvICAGxHhRO2NnP3pWzb732Xd5UXum6plbb3ueIKGUIAuSAnmzRvmh0ma9c1ZB7z38dGYDTLUBeUW0cDR74f24aiij-vrnlSPl8aXvXDh_mCPkmivwvkfAL3bp4-w</recordid><startdate>20110301</startdate><enddate>20110301</enddate><creator>Omamogho, Jesse O</creator><creator>Glennon, Jeremy D</creator><general>American Chemical Society</general><scope>IQODW</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>20110301</creationdate><title>Comparison between the Efficiencies of sub-2 μm C18 Particles Packed in Narrow Bore Columns</title><author>Omamogho, Jesse O ; Glennon, Jeremy D</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a271t-46f5b85a7805d8e910904b0d30c4999352f6ce9baaad3078ae0fdb6f2207e2073</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>Chromatographic methods and physical methods associated with chromatography</topic><topic>Exact sciences and technology</topic><topic>Other chromatographic methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Omamogho, Jesse O</creatorcontrib><creatorcontrib>Glennon, Jeremy D</creatorcontrib><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Omamogho, Jesse O</au><au>Glennon, Jeremy D</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison between the Efficiencies of sub-2 μm C18 Particles Packed in Narrow Bore Columns</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>2011-03-01</date><risdate>2011</risdate><volume>83</volume><issue>5</issue><spage>1547</spage><epage>1556</epage><pages>1547-1556</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><coden>ANCHAM</coden><abstract>The chromatographic performance of two types of core−shell particles and two fully porous particles packed in 2.1 ID × 50 mm columns was investigated. Comparisons of the performances of the EiS-150-C18 to that of the Kinetex-1.7 μm-C18, Acquity-BEH-1.7 μm-C18, and Zorbax-XDB-1.8 μm-C18 are made and discussed. The physical factors that govern the performance of these columns, such as particle size distribution and column external, total, and particle porosity of the C18 packing materials were among the prime foci of investigation. The differences in the mass transfer behavior measured using naphtho[2,3-a]pyrene between these columns provides an indication of improved performance of the new EiS-150-C18 column. The minimum reduced height equivalent to a theoretical plate (HETP) value for the EiS-150-C18, h min = 1.95, was achieved and was comparable to that obtained from the C18 phases of the Kinetex (h min = 2.53), the Acquity (h min = 2.26), and the Zorbax (h min = 2.57) columns. This study reveals the importance of the dimension of the shell thickness in controlling the performance of columns packed with shell particles in narrow bore columns.</abstract><cop>Washington, DC</cop><pub>American Chemical Society</pub><pmid>21291175</pmid><doi>10.1021/ac102139a</doi><tpages>10</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2700 |
ispartof | Analytical chemistry (Washington), 2011-03, Vol.83 (5), p.1547-1556 |
issn | 0003-2700 1520-6882 |
language | eng |
recordid | cdi_proquest_miscellaneous_1115530205 |
source | American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list) |
subjects | Analytical chemistry Chemistry Chromatographic methods and physical methods associated with chromatography Exact sciences and technology Other chromatographic methods |
title | Comparison between the Efficiencies of sub-2 μm C18 Particles Packed in Narrow Bore Columns |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T07%3A34%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20between%20the%20Efficiencies%20of%20sub-2%20%CE%BCm%20C18%20Particles%20Packed%20in%20Narrow%20Bore%20Columns&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Omamogho,%20Jesse%20O&rft.date=2011-03-01&rft.volume=83&rft.issue=5&rft.spage=1547&rft.epage=1556&rft.pages=1547-1556&rft.issn=0003-2700&rft.eissn=1520-6882&rft.coden=ANCHAM&rft_id=info:doi/10.1021/ac102139a&rft_dat=%3Cproquest_pubme%3E1115530205%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a271t-46f5b85a7805d8e910904b0d30c4999352f6ce9baaad3078ae0fdb6f2207e2073%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1115530205&rft_id=info:pmid/21291175&rfr_iscdi=true |