Loading…

Behavior of Axially Loaded Concrete Wall Panels with Openings: An Experimental Study

Forty seven reinforced concrete walls with various opening configurations are tested in both one-way and two-way action. The test panels, with a slenderness ratio of 30, 35 or 40, were subjected to a uniformly distributed axial load at an eccentricity of one sixth of the wall thickness (tw/6). Apart...

Full description

Saved in:
Bibliographic Details
Published in:Advances in structural engineering 2012-08, Vol.15 (8), p.1345-1358
Main Authors: Fragomeni, S., Doh, J.H., Lee, D.J.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Forty seven reinforced concrete walls with various opening configurations are tested in both one-way and two-way action. The test panels, with a slenderness ratio of 30, 35 or 40, were subjected to a uniformly distributed axial load at an eccentricity of one sixth of the wall thickness (tw/6). Apart from highlighting the experimental set-up; typical crack patterns, failure modes, and load-deflection behaviour of test panels are also reported. Actual test failure loads are compared to ultimate load predictions using the Australian standard wall design equation and also a recently derived formula specifically for walls with openings. The code equation is found to be inadequate for the many cases investigated whereas the derived formula was verified as being adequate in predicting failure load of walls with openings.
ISSN:1369-4332
2048-4011
DOI:10.1260/1369-4332.15.8.1345