Loading…
Indirect calorimetry during non invasive mechanical ventilation. Is the next step for gas exchange monitoring?
We analyze validation and some technical aspects of indirect calorimetry for measurement of energy expenditure in healthy volunteers undergoing pressure controlled non-invasive ventilation (NIMV). This validation study assess the reliability of gas exchange measurement with indirect calorimetry amon...
Saved in:
Published in: | Journal of clinical monitoring and computing 2013-02, Vol.27 (1), p.99-100 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c415t-3a6e1717f5ff71f0a75a6e66bc99f95d18415326abc8d6806eceaab352c7e82d3 |
---|---|
cites | cdi_FETCH-LOGICAL-c415t-3a6e1717f5ff71f0a75a6e66bc99f95d18415326abc8d6806eceaab352c7e82d3 |
container_end_page | 100 |
container_issue | 1 |
container_start_page | 99 |
container_title | Journal of clinical monitoring and computing |
container_volume | 27 |
creator | Esquinas, Antonio M. Koksal, Güniz |
description | We analyze validation and some technical aspects of indirect calorimetry for measurement of energy expenditure in healthy volunteers undergoing pressure controlled non-invasive ventilation (NIMV). This validation study assess the reliability of gas exchange measurement with indirect calorimetry among subjects who undergo, oxygen consumption and carbon dioxide production measure. These comments of indirect calorimetry during NIMV should take it into account for real situations in clinical practice. |
doi_str_mv | 10.1007/s10877-012-9396-3 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1273627458</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2867786521</sourcerecordid><originalsourceid>FETCH-LOGICAL-c415t-3a6e1717f5ff71f0a75a6e66bc99f95d18415326abc8d6806eceaab352c7e82d3</originalsourceid><addsrcrecordid>eNp1kUFrGzEQhUVpaJykP6CXIuill3U0klfaPZUSmsQQyCU5C1k76yisJVfSGvvfR4uTUgI5jRi-90a8R8g3YHNgTF0mYI1SFQNetaKVlfhEZlArUXEJi8_lLRpVgWDqlJyl9MwYaxsBX8gpLzsmW5gRv_Sdi2gztWYI0W0wxwPtxuj8mvrgqfM7k9wO6Qbtk_GuYHSHPrvBZBf8nC4TzU9IPe4zTRm3tA-Rrk2iuJ8E66IM3uUwOf66ICe9GRJ-fZ3n5PH6z8PVbXV3f7O8-n1X2QXUuRJGIihQfd33CnpmVF02Uq5s2_Zt3UFTMMGlWdmmkw2TaNGYlai5VdjwTpyTn0ffbQx_R0xZb1yyOAzGYxiTBq6E5GpRNwX98Q59DmP05XcTxUQNC8ELBUfKxpBSxF5vS1gmHjQwPZWhj2XoUoaeytCiaL6_Oo-rDXb_FG_pF4AfgbSd0sH43-kPXV8AoM-Vpw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1270351432</pqid></control><display><type>article</type><title>Indirect calorimetry during non invasive mechanical ventilation. Is the next step for gas exchange monitoring?</title><source>Springer Nature</source><creator>Esquinas, Antonio M. ; Koksal, Güniz</creator><creatorcontrib>Esquinas, Antonio M. ; Koksal, Güniz</creatorcontrib><description>We analyze validation and some technical aspects of indirect calorimetry for measurement of energy expenditure in healthy volunteers undergoing pressure controlled non-invasive ventilation (NIMV). This validation study assess the reliability of gas exchange measurement with indirect calorimetry among subjects who undergo, oxygen consumption and carbon dioxide production measure. These comments of indirect calorimetry during NIMV should take it into account for real situations in clinical practice.</description><identifier>ISSN: 1387-1307</identifier><identifier>EISSN: 1573-2614</identifier><identifier>DOI: 10.1007/s10877-012-9396-3</identifier><identifier>PMID: 23070691</identifier><identifier>CODEN: JCMCFG</identifier><language>eng</language><publisher>Dordrecht: Springer Netherlands</publisher><subject>Anesthesiology ; Calorimetry, Indirect - methods ; Carbon Dioxide - metabolism ; Critical Care Medicine ; Energy Metabolism - physiology ; Health Sciences ; Humans ; Intensive ; Letter to the Editor ; Male ; Medicine ; Medicine & Public Health ; Monitoring, Physiologic - methods ; Oxygen Consumption - physiology ; Positive-Pressure Respiration ; Pulmonary Gas Exchange - physiology ; Respiration, Artificial - methods ; Statistics for Life Sciences ; Young Adult</subject><ispartof>Journal of clinical monitoring and computing, 2013-02, Vol.27 (1), p.99-100</ispartof><rights>Springer Science+Business Media, LLC 2012</rights><rights>Springer Science+Business Media New York 2013</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c415t-3a6e1717f5ff71f0a75a6e66bc99f95d18415326abc8d6806eceaab352c7e82d3</citedby><cites>FETCH-LOGICAL-c415t-3a6e1717f5ff71f0a75a6e66bc99f95d18415326abc8d6806eceaab352c7e82d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23070691$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Esquinas, Antonio M.</creatorcontrib><creatorcontrib>Koksal, Güniz</creatorcontrib><title>Indirect calorimetry during non invasive mechanical ventilation. Is the next step for gas exchange monitoring?</title><title>Journal of clinical monitoring and computing</title><addtitle>J Clin Monit Comput</addtitle><addtitle>J Clin Monit Comput</addtitle><description>We analyze validation and some technical aspects of indirect calorimetry for measurement of energy expenditure in healthy volunteers undergoing pressure controlled non-invasive ventilation (NIMV). This validation study assess the reliability of gas exchange measurement with indirect calorimetry among subjects who undergo, oxygen consumption and carbon dioxide production measure. These comments of indirect calorimetry during NIMV should take it into account for real situations in clinical practice.</description><subject>Anesthesiology</subject><subject>Calorimetry, Indirect - methods</subject><subject>Carbon Dioxide - metabolism</subject><subject>Critical Care Medicine</subject><subject>Energy Metabolism - physiology</subject><subject>Health Sciences</subject><subject>Humans</subject><subject>Intensive</subject><subject>Letter to the Editor</subject><subject>Male</subject><subject>Medicine</subject><subject>Medicine & Public Health</subject><subject>Monitoring, Physiologic - methods</subject><subject>Oxygen Consumption - physiology</subject><subject>Positive-Pressure Respiration</subject><subject>Pulmonary Gas Exchange - physiology</subject><subject>Respiration, Artificial - methods</subject><subject>Statistics for Life Sciences</subject><subject>Young Adult</subject><issn>1387-1307</issn><issn>1573-2614</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNp1kUFrGzEQhUVpaJykP6CXIuill3U0klfaPZUSmsQQyCU5C1k76yisJVfSGvvfR4uTUgI5jRi-90a8R8g3YHNgTF0mYI1SFQNetaKVlfhEZlArUXEJi8_lLRpVgWDqlJyl9MwYaxsBX8gpLzsmW5gRv_Sdi2gztWYI0W0wxwPtxuj8mvrgqfM7k9wO6Qbtk_GuYHSHPrvBZBf8nC4TzU9IPe4zTRm3tA-Rrk2iuJ8E66IM3uUwOf66ICe9GRJ-fZ3n5PH6z8PVbXV3f7O8-n1X2QXUuRJGIihQfd33CnpmVF02Uq5s2_Zt3UFTMMGlWdmmkw2TaNGYlai5VdjwTpyTn0ffbQx_R0xZb1yyOAzGYxiTBq6E5GpRNwX98Q59DmP05XcTxUQNC8ELBUfKxpBSxF5vS1gmHjQwPZWhj2XoUoaeytCiaL6_Oo-rDXb_FG_pF4AfgbSd0sH43-kPXV8AoM-Vpw</recordid><startdate>20130201</startdate><enddate>20130201</enddate><creator>Esquinas, Antonio M.</creator><creator>Koksal, Güniz</creator><general>Springer Netherlands</general><general>Springer Nature B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7RV</scope><scope>7SC</scope><scope>7SP</scope><scope>7U5</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AO</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>JQ2</scope><scope>K7-</scope><scope>K9.</scope><scope>KB0</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>M0S</scope><scope>M1P</scope><scope>NAPCQ</scope><scope>P5Z</scope><scope>P62</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope></search><sort><creationdate>20130201</creationdate><title>Indirect calorimetry during non invasive mechanical ventilation. Is the next step for gas exchange monitoring?</title><author>Esquinas, Antonio M. ; Koksal, Güniz</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c415t-3a6e1717f5ff71f0a75a6e66bc99f95d18415326abc8d6806eceaab352c7e82d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Anesthesiology</topic><topic>Calorimetry, Indirect - methods</topic><topic>Carbon Dioxide - metabolism</topic><topic>Critical Care Medicine</topic><topic>Energy Metabolism - physiology</topic><topic>Health Sciences</topic><topic>Humans</topic><topic>Intensive</topic><topic>Letter to the Editor</topic><topic>Male</topic><topic>Medicine</topic><topic>Medicine & Public Health</topic><topic>Monitoring, Physiologic - methods</topic><topic>Oxygen Consumption - physiology</topic><topic>Positive-Pressure Respiration</topic><topic>Pulmonary Gas Exchange - physiology</topic><topic>Respiration, Artificial - methods</topic><topic>Statistics for Life Sciences</topic><topic>Young Adult</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Esquinas, Antonio M.</creatorcontrib><creatorcontrib>Koksal, Güniz</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Nursing & Allied Health Database</collection><collection>Computer and Information Systems Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>Advanced Technologies & Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Computer Science Collection</collection><collection>Computer Science Database</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Nursing & Allied Health Database (Alumni Edition)</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Nursing & Allied Health Premium</collection><collection>Advanced Technologies & Aerospace Database</collection><collection>ProQuest Advanced Technologies & Aerospace Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of clinical monitoring and computing</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Esquinas, Antonio M.</au><au>Koksal, Güniz</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Indirect calorimetry during non invasive mechanical ventilation. Is the next step for gas exchange monitoring?</atitle><jtitle>Journal of clinical monitoring and computing</jtitle><stitle>J Clin Monit Comput</stitle><addtitle>J Clin Monit Comput</addtitle><date>2013-02-01</date><risdate>2013</risdate><volume>27</volume><issue>1</issue><spage>99</spage><epage>100</epage><pages>99-100</pages><issn>1387-1307</issn><eissn>1573-2614</eissn><coden>JCMCFG</coden><abstract>We analyze validation and some technical aspects of indirect calorimetry for measurement of energy expenditure in healthy volunteers undergoing pressure controlled non-invasive ventilation (NIMV). This validation study assess the reliability of gas exchange measurement with indirect calorimetry among subjects who undergo, oxygen consumption and carbon dioxide production measure. These comments of indirect calorimetry during NIMV should take it into account for real situations in clinical practice.</abstract><cop>Dordrecht</cop><pub>Springer Netherlands</pub><pmid>23070691</pmid><doi>10.1007/s10877-012-9396-3</doi><tpages>2</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1387-1307 |
ispartof | Journal of clinical monitoring and computing, 2013-02, Vol.27 (1), p.99-100 |
issn | 1387-1307 1573-2614 |
language | eng |
recordid | cdi_proquest_miscellaneous_1273627458 |
source | Springer Nature |
subjects | Anesthesiology Calorimetry, Indirect - methods Carbon Dioxide - metabolism Critical Care Medicine Energy Metabolism - physiology Health Sciences Humans Intensive Letter to the Editor Male Medicine Medicine & Public Health Monitoring, Physiologic - methods Oxygen Consumption - physiology Positive-Pressure Respiration Pulmonary Gas Exchange - physiology Respiration, Artificial - methods Statistics for Life Sciences Young Adult |
title | Indirect calorimetry during non invasive mechanical ventilation. Is the next step for gas exchange monitoring? |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-12T00%3A04%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Indirect%20calorimetry%20during%20non%20invasive%20mechanical%20ventilation.%20Is%20the%20next%20step%20for%20gas%20exchange%20monitoring?&rft.jtitle=Journal%20of%20clinical%20monitoring%20and%20computing&rft.au=Esquinas,%20Antonio%20M.&rft.date=2013-02-01&rft.volume=27&rft.issue=1&rft.spage=99&rft.epage=100&rft.pages=99-100&rft.issn=1387-1307&rft.eissn=1573-2614&rft.coden=JCMCFG&rft_id=info:doi/10.1007/s10877-012-9396-3&rft_dat=%3Cproquest_cross%3E2867786521%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c415t-3a6e1717f5ff71f0a75a6e66bc99f95d18415326abc8d6806eceaab352c7e82d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1270351432&rft_id=info:pmid/23070691&rfr_iscdi=true |