Nonfluoroscopic Catheter Ablation of a Double-Loop Re-entry Tachycardia Guided by Real-Time Contact Force Information

Abstract Nonfluoroscopic catheter ablation has been demonstrated for typical arrhythmias. It is important to note that insufficient contact force may result in an ineffective lesion, whereas excessive contact force may result in complications. Herein, we demonstrate nonfluoroscopic mapping and ablat...

Full description

Saved in:
Bibliographic Details
Published in:Canadian journal of cardiology 2013-02, Vol.29 (2), p.254.e9-254.e11
Main Authors: Eickholt, Christian, MD, Boring, Yang C., MD, Kelm, Malte, MD, FESC, Shin, Dong-In, MD, Meyer, Christian, MD
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract Nonfluoroscopic catheter ablation has been demonstrated for typical arrhythmias. It is important to note that insufficient contact force may result in an ineffective lesion, whereas excessive contact force may result in complications. Herein, we demonstrate nonfluoroscopic mapping and ablation of a cavotricuspid isthmus–dependent double-loop re-entry tachycardia guided by real-time contact force information. Periprocedural delayed-enhancement magnetic resonance imaging supported the presence of the ablation lesion without any other evidence of a scar substrate for this arrhythmia.
ISSN:0828-282X