Loading…

The Impact of Hemodialysis on the Dispersion of Ventricular Repolarization

Background Sudden cardiac death is prevalent in chronic hemodialysis (HD) patients while the dialysis process may have arrhythmogenic potential. We sought to examine the effect of HD on conventional electrocardiographic parameters as well as on novel indexes of repolarization, given that increased s...

Full description

Saved in:
Bibliographic Details
Published in:Pacing and clinical electrophysiology 2013-03, Vol.36 (3), p.322-327
Main Authors: KALANTZI, KALLIRROI, GOUVA, CHARA, LETSAS, KONSTANTINOS P., VLACHOPANOU, APHRODITE, FOULIDIS, VALERIOS, BECHLIOULIS, ARIS, KATOPODIS, KONSTANTINOS P., GOUDEVENOS, JOHN A., KORANTZOPOULOS, PANAGIOTIS
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background Sudden cardiac death is prevalent in chronic hemodialysis (HD) patients while the dialysis process may have arrhythmogenic potential. We sought to examine the effect of HD on conventional electrocardiographic parameters as well as on novel indexes of repolarization, given that increased spatial dispersion of repolarization is related to ventricular arrhythmias. Methods We recorded clinical, echocardiographic, and laboratory parameters as well as electrocardiographic indexes before and after a single HD session. Specifically, we calculated the QTc interval, the QRS duration, the T peak‐to‐end (Tpe) interval, and the Tpe/QT ratio. Results The study population consisted of 66 chronic HD patients (mean age: 68.9 ± 11.8 years, 40 males). Heart rate, blood pressure, QRS duration, QTc interval, and QT dispersion did not change significantly after the HD session. However, the Tpe interval and the Tpe/QT ratio increased significantly (80 [65–90] ms vs 85 [77.5–100] ms; P = 0.04, and 0.21 [0.18–0.24] vs 0.25 [0.21–0.28]; P = 0.05, respectively). Correlation analysis and multiple regression analysis failed to show significant associations between the baseline parameters and the baseline values of Tpe and Tpe/QT or between the change of the laboratory parameters during HD and the corresponding change of the Tpe and the Tpe/QT values. No significant arrhythmias were observed during the HD sessions. Conclusions HD induces an increase in novel markers of spatial dispersion of ventricular repolarization. Whether the assessment of these indexes of heterogeneity of repolarization at baseline or their change during HD has a prognostic value with regard to future untoward events, remains to be elucidated.
ISSN:0147-8389
1540-8159
DOI:10.1111/pace.12066