Loading…

Minimum quench power dissipation and current non-uniformity in international thermonuclear experimental reactor type NbTi cable-in-conduit conductor samples under direct current conditions

The level of current non-uniformity in NbTi cable-in-conduit conductors (CICCs) sections near the joints in combination with the magnetic field profile needs attention in view of proper joint design. The strand joule power and current distribution at quench under DC conditions of two samples of ITER...

Full description

Saved in:
Bibliographic Details
Published in:Journal of applied physics 2012-05, Vol.111 (9), p.093904-093904-11
Main Authors: Rolando, G., van Lanen, E. P. A., Nijhuis, A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c352t-43470af8333cb119b2596b935ec370cdd4aefc9bf4f34a8be193129808fd00033
cites cdi_FETCH-LOGICAL-c352t-43470af8333cb119b2596b935ec370cdd4aefc9bf4f34a8be193129808fd00033
container_end_page 093904-11
container_issue 9
container_start_page 093904
container_title Journal of applied physics
container_volume 111
creator Rolando, G.
van Lanen, E. P. A.
Nijhuis, A.
description The level of current non-uniformity in NbTi cable-in-conduit conductors (CICCs) sections near the joints in combination with the magnetic field profile needs attention in view of proper joint design. The strand joule power and current distribution at quench under DC conditions of two samples of ITER poloidal field coil conductors, as tested in the SULTAN facility, and of the so called PFCI model coil insert, have been analyzed with the numerical cable model JackPot. The precise trajectories of all individual strands, joint design, cabling configuration, spatial distribution of the magnetic field, sample geometry, and experimentally determined interstrand resistance distributions have been taken into account. Although unable to predict the quench point due to the lack of a thermal-hydraulic routine, the model allows to assess the instantaneous strand power at quench and its local distribution in the cable once the quench conditions in terms of current and temperature are experimentally known. The analysis points out the relation of the above mentioned factors with the DC quench stability of both short samples and coils. The possible small scale and local electrical-thermal interactions were ignored in order to examine the relevance of such effects in the overall prediction of the CICC performance. The electromagnetic code shows an excellent quantitative predictive potential for CICC transport properties, excluding any freedom for matching the results. The influence of the local thermal effects in the modeling is identified as being marginal and far less than the generally accepted temperature margin for safe operation.
doi_str_mv 10.1063/1.4709438
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1323213117</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1323213117</sourcerecordid><originalsourceid>FETCH-LOGICAL-c352t-43470af8333cb119b2596b935ec370cdd4aefc9bf4f34a8be193129808fd00033</originalsourceid><addsrcrecordid>eNp1kctO5DAQRS00SPQ0LPgDL5lFwJVKSLxBGqHhIfHYwNpynIowSuxgO5rpf-PjSKdbs0OyVAufeugexk5BnIO4xAs4LyohC6wP2ApELbOqLMUPthIih6yWlTxiP2N8FwKgRrlin4_W2WEa-MdEzrzx0f-lwFsbox11st5x7VpuphDIJe68yyZnOx8GmzbcuvklCm4hdc_TG4XBu8n0pAOnfyMFO8yN81cgbZIPPG1G4k_Ni-VGNz1l1mXGu3ayiS91gaIexp4in1y7XBPIpP9HbDG7XRiP2WGn-0gn-7pmrzd_Xq7vsofn2_vr3w-ZwTJPWYFzJrqrEdE0ALLJS3nZSCzJYCVM2xaaOiObruiw0HVDIBFyWYu6a4UQiGt2tps7Bj_nFJMabDTU99qRn6ICzDEHBKhm9NcONcHHGKhT4xyBDhsFQm0NKVB7QzN7tWOjsWmJ8Ht4r0ntNKlFE34B6kKfJg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1323213117</pqid></control><display><type>article</type><title>Minimum quench power dissipation and current non-uniformity in international thermonuclear experimental reactor type NbTi cable-in-conduit conductor samples under direct current conditions</title><source>American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)</source><creator>Rolando, G. ; van Lanen, E. P. A. ; Nijhuis, A.</creator><creatorcontrib>Rolando, G. ; van Lanen, E. P. A. ; Nijhuis, A.</creatorcontrib><description>The level of current non-uniformity in NbTi cable-in-conduit conductors (CICCs) sections near the joints in combination with the magnetic field profile needs attention in view of proper joint design. The strand joule power and current distribution at quench under DC conditions of two samples of ITER poloidal field coil conductors, as tested in the SULTAN facility, and of the so called PFCI model coil insert, have been analyzed with the numerical cable model JackPot. The precise trajectories of all individual strands, joint design, cabling configuration, spatial distribution of the magnetic field, sample geometry, and experimentally determined interstrand resistance distributions have been taken into account. Although unable to predict the quench point due to the lack of a thermal-hydraulic routine, the model allows to assess the instantaneous strand power at quench and its local distribution in the cable once the quench conditions in terms of current and temperature are experimentally known. The analysis points out the relation of the above mentioned factors with the DC quench stability of both short samples and coils. The possible small scale and local electrical-thermal interactions were ignored in order to examine the relevance of such effects in the overall prediction of the CICC performance. The electromagnetic code shows an excellent quantitative predictive potential for CICC transport properties, excluding any freedom for matching the results. The influence of the local thermal effects in the modeling is identified as being marginal and far less than the generally accepted temperature margin for safe operation.</description><identifier>ISSN: 0021-8979</identifier><identifier>EISSN: 1089-7550</identifier><identifier>DOI: 10.1063/1.4709438</identifier><identifier>CODEN: JAPIAU</identifier><language>eng</language><publisher>American Institute of Physics</publisher><subject>Coiling ; Conductors (devices) ; Direct current ; Electric power generation ; Magnetic fields ; Mathematical models ; Niobium base alloys ; Strands</subject><ispartof>Journal of applied physics, 2012-05, Vol.111 (9), p.093904-093904-11</ispartof><rights>2012 American Institute of Physics</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c352t-43470af8333cb119b2596b935ec370cdd4aefc9bf4f34a8be193129808fd00033</citedby><cites>FETCH-LOGICAL-c352t-43470af8333cb119b2596b935ec370cdd4aefc9bf4f34a8be193129808fd00033</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Rolando, G.</creatorcontrib><creatorcontrib>van Lanen, E. P. A.</creatorcontrib><creatorcontrib>Nijhuis, A.</creatorcontrib><title>Minimum quench power dissipation and current non-uniformity in international thermonuclear experimental reactor type NbTi cable-in-conduit conductor samples under direct current conditions</title><title>Journal of applied physics</title><description>The level of current non-uniformity in NbTi cable-in-conduit conductors (CICCs) sections near the joints in combination with the magnetic field profile needs attention in view of proper joint design. The strand joule power and current distribution at quench under DC conditions of two samples of ITER poloidal field coil conductors, as tested in the SULTAN facility, and of the so called PFCI model coil insert, have been analyzed with the numerical cable model JackPot. The precise trajectories of all individual strands, joint design, cabling configuration, spatial distribution of the magnetic field, sample geometry, and experimentally determined interstrand resistance distributions have been taken into account. Although unable to predict the quench point due to the lack of a thermal-hydraulic routine, the model allows to assess the instantaneous strand power at quench and its local distribution in the cable once the quench conditions in terms of current and temperature are experimentally known. The analysis points out the relation of the above mentioned factors with the DC quench stability of both short samples and coils. The possible small scale and local electrical-thermal interactions were ignored in order to examine the relevance of such effects in the overall prediction of the CICC performance. The electromagnetic code shows an excellent quantitative predictive potential for CICC transport properties, excluding any freedom for matching the results. The influence of the local thermal effects in the modeling is identified as being marginal and far less than the generally accepted temperature margin for safe operation.</description><subject>Coiling</subject><subject>Conductors (devices)</subject><subject>Direct current</subject><subject>Electric power generation</subject><subject>Magnetic fields</subject><subject>Mathematical models</subject><subject>Niobium base alloys</subject><subject>Strands</subject><issn>0021-8979</issn><issn>1089-7550</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNp1kctO5DAQRS00SPQ0LPgDL5lFwJVKSLxBGqHhIfHYwNpynIowSuxgO5rpf-PjSKdbs0OyVAufeugexk5BnIO4xAs4LyohC6wP2ApELbOqLMUPthIih6yWlTxiP2N8FwKgRrlin4_W2WEa-MdEzrzx0f-lwFsbox11st5x7VpuphDIJe68yyZnOx8GmzbcuvklCm4hdc_TG4XBu8n0pAOnfyMFO8yN81cgbZIPPG1G4k_Ni-VGNz1l1mXGu3ayiS91gaIexp4in1y7XBPIpP9HbDG7XRiP2WGn-0gn-7pmrzd_Xq7vsofn2_vr3w-ZwTJPWYFzJrqrEdE0ALLJS3nZSCzJYCVM2xaaOiObruiw0HVDIBFyWYu6a4UQiGt2tps7Bj_nFJMabDTU99qRn6ICzDEHBKhm9NcONcHHGKhT4xyBDhsFQm0NKVB7QzN7tWOjsWmJ8Ht4r0ntNKlFE34B6kKfJg</recordid><startdate>20120501</startdate><enddate>20120501</enddate><creator>Rolando, G.</creator><creator>van Lanen, E. P. A.</creator><creator>Nijhuis, A.</creator><general>American Institute of Physics</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20120501</creationdate><title>Minimum quench power dissipation and current non-uniformity in international thermonuclear experimental reactor type NbTi cable-in-conduit conductor samples under direct current conditions</title><author>Rolando, G. ; van Lanen, E. P. A. ; Nijhuis, A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c352t-43470af8333cb119b2596b935ec370cdd4aefc9bf4f34a8be193129808fd00033</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Coiling</topic><topic>Conductors (devices)</topic><topic>Direct current</topic><topic>Electric power generation</topic><topic>Magnetic fields</topic><topic>Mathematical models</topic><topic>Niobium base alloys</topic><topic>Strands</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rolando, G.</creatorcontrib><creatorcontrib>van Lanen, E. P. A.</creatorcontrib><creatorcontrib>Nijhuis, A.</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of applied physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rolando, G.</au><au>van Lanen, E. P. A.</au><au>Nijhuis, A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Minimum quench power dissipation and current non-uniformity in international thermonuclear experimental reactor type NbTi cable-in-conduit conductor samples under direct current conditions</atitle><jtitle>Journal of applied physics</jtitle><date>2012-05-01</date><risdate>2012</risdate><volume>111</volume><issue>9</issue><spage>093904</spage><epage>093904-11</epage><pages>093904-093904-11</pages><issn>0021-8979</issn><eissn>1089-7550</eissn><coden>JAPIAU</coden><abstract>The level of current non-uniformity in NbTi cable-in-conduit conductors (CICCs) sections near the joints in combination with the magnetic field profile needs attention in view of proper joint design. The strand joule power and current distribution at quench under DC conditions of two samples of ITER poloidal field coil conductors, as tested in the SULTAN facility, and of the so called PFCI model coil insert, have been analyzed with the numerical cable model JackPot. The precise trajectories of all individual strands, joint design, cabling configuration, spatial distribution of the magnetic field, sample geometry, and experimentally determined interstrand resistance distributions have been taken into account. Although unable to predict the quench point due to the lack of a thermal-hydraulic routine, the model allows to assess the instantaneous strand power at quench and its local distribution in the cable once the quench conditions in terms of current and temperature are experimentally known. The analysis points out the relation of the above mentioned factors with the DC quench stability of both short samples and coils. The possible small scale and local electrical-thermal interactions were ignored in order to examine the relevance of such effects in the overall prediction of the CICC performance. The electromagnetic code shows an excellent quantitative predictive potential for CICC transport properties, excluding any freedom for matching the results. The influence of the local thermal effects in the modeling is identified as being marginal and far less than the generally accepted temperature margin for safe operation.</abstract><pub>American Institute of Physics</pub><doi>10.1063/1.4709438</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0021-8979
ispartof Journal of applied physics, 2012-05, Vol.111 (9), p.093904-093904-11
issn 0021-8979
1089-7550
language eng
recordid cdi_proquest_miscellaneous_1323213117
source American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)
subjects Coiling
Conductors (devices)
Direct current
Electric power generation
Magnetic fields
Mathematical models
Niobium base alloys
Strands
title Minimum quench power dissipation and current non-uniformity in international thermonuclear experimental reactor type NbTi cable-in-conduit conductor samples under direct current conditions
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-14T03%3A45%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Minimum%20quench%20power%20dissipation%20and%20current%20non-uniformity%20in%20international%20thermonuclear%20experimental%20reactor%20type%20NbTi%20cable-in-conduit%20conductor%20samples%20under%20direct%20current%20conditions&rft.jtitle=Journal%20of%20applied%20physics&rft.au=Rolando,%20G.&rft.date=2012-05-01&rft.volume=111&rft.issue=9&rft.spage=093904&rft.epage=093904-11&rft.pages=093904-093904-11&rft.issn=0021-8979&rft.eissn=1089-7550&rft.coden=JAPIAU&rft_id=info:doi/10.1063/1.4709438&rft_dat=%3Cproquest_cross%3E1323213117%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c352t-43470af8333cb119b2596b935ec370cdd4aefc9bf4f34a8be193129808fd00033%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1323213117&rft_id=info:pmid/&rfr_iscdi=true