Loading…
Radiation transmission of concrete including pumice for 662, 1173 and 1332 keV gamma rays
The photon attenuation coefficients of concretes produced using pumice as an aggregate, have been measured at the photon energies of 662, 1173 and 1332 keV to test the radiation shielding properties. The measured results have been compared with the calculation which has been done by using XCOM compu...
Saved in:
Published in: | Nuclear engineering and design 2012-11, Vol.252, p.163-166 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The photon attenuation coefficients of concretes produced using pumice as an aggregate, have been measured at the photon energies of 662, 1173 and 1332 keV to test the radiation shielding properties. The measured results have been compared with the calculation which has been done by using XCOM computer code. The obtained results have also been compared with the normal type of concrete in order to see the effect of pumice to radiation shielding properties. |
---|---|
ISSN: | 0029-5493 1872-759X |
DOI: | 10.1016/j.nucengdes.2012.07.008 |