Loading…
A margin-of-the-day online adaptive intensity-modulated radiotherapy strategy for cervical cancer provides superior treatment accuracy compared to clinically recommended margins: A dosimetric evaluation
Abstract Purpose. To dosimetrically evaluate a margin-of-the-day (MoD) online adaptive intensity-modulated radiotherapy (IMRT) strategy for cervical cancer patients. The strategy is based on a single planning computed tomography (CT) scan and a pretreatment constructed IMRT plan library with increme...
Saved in:
Published in: | Acta oncologica 2013-10, Vol.52 (7), p.1430-1436 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Abstract
Purpose. To dosimetrically evaluate a margin-of-the-day (MoD) online adaptive intensity-modulated radiotherapy (IMRT) strategy for cervical cancer patients. The strategy is based on a single planning computed tomography (CT) scan and a pretreatment constructed IMRT plan library with incremental clinical target volumes (CTV)-to-planning target volumes (PTV) margins. Material and methods. For 14 patients, 9-10 variable bladder filling CT scans acquired at pretreatment and after 40 Gy were available. Bladder volume variability during the treatment course was recorded by twice-weekly US bladder-volume measurements. A MoD strategy that selects the best IMRT plan of the day from a library of plans with incremental margins in steps of 5 mm was compared with a clinically recommended population-based margin (15 mm). To compare the strategies, for each fraction that had a recorded US bladder-volume measurement, the CT scan with the nearest bladder volume was selected from the pretreatment CT series and from the CT series acquired after 40 Gy. A frequency-weighted average of the dose-volume histograms (DVH) parameters calculated for the two selected CT scans was used to estimate the DVH parameters of the fraction of interest. Results. The 15-mm recommended margin resulted in cervix-uterus underdosage in six of 14 patients. Compared with the 15-mm margin, the MoD strategy resulted in significantly better cervix-uterus coverage (p = 0.008) without a significant difference in the sparing of rectum, bladder, and small bowel. For each patient, 3-8 (median 5) plans were needed in the library of plans for the MoD strategy. The required range of the MoD was 5-45 mm (median 15 mm). Twenty-five percent of all fractions could be treated with a MoD of 5 mm and 81% of all fractions could be treated with a MoD up to 25 mm. Conclusions. Compared with a clinically recommended margin, a simple online adaptive strategy resulted in better cervix-uterus coverage without compromising organs at risk sparing. |
---|---|
ISSN: | 0284-186X 1651-226X |
DOI: | 10.3109/0284186X.2013.813640 |