Loading…

Determination of indicator polychlorinated biphenyls (PCBs) by gas chromatography–electron capture detector

•We report of validated GC–ECD method for the determination of indicator PCBs.•Validated GC–ECD method was applied to determine levels of the PCBs in sediments.•PCB 52 and PCB 101 was the most ubiquitous indicator PCBs in the study area.•Threehours of sonication gave the optimum extraction yield for...

Full description

Saved in:
Bibliographic Details
Published in:Chemosphere (Oxford) 2013-11, Vol.93 (8), p.1556-1560
Main Authors: Afful, Samuel, Awudza, Johannes A.M., Twumasi, Stevester K., Osae, Shiloh
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:•We report of validated GC–ECD method for the determination of indicator PCBs.•Validated GC–ECD method was applied to determine levels of the PCBs in sediments.•PCB 52 and PCB 101 was the most ubiquitous indicator PCBs in the study area.•Threehours of sonication gave the optimum extraction yield for the PCBs. An effective method for determination of indicator polychlorinated biphenyls (PCBs) has been validated using gas chromatography (GC) equipped with electron capture detector (ECD). The GC–ECD method was validated by determining the linear range (working range) for determination of the compounds, minimum detectable quantities (MDQ), the precision and accuracy of the method for the analysis of the compounds. MDQ obtained for the compounds ranges from 0.0005 to 0.002ng. Indeed the method was found to be more sensitive as the number of chlorine atoms attached to the biphenyl increases. The precision and accuracy of the GC method validated ranges from 2.4% to 14.5% and −7.0% to 14.6% respectively. Coefficient of variation associated with the repeatability of the retention times and corresponding peak areas was found to be 0.0001–0.0007 for the retention times and 0.0014–0.059 for the peak areas. Percentage recoveries for the compounds were in the range of 95.7–101.0%. The validated method was then applied to determine levels of indicator PCBs in sediments sampled from eleven sampling points along the Lake Bosuntwi in Ghana and the highest PCB load of 19.17ngg−1 was recorded at Pipie No. 2. PCB 52 and PCB 101 were found to be the most ubiquitous indicator PCBs in the study area, both with 90.91% occurrence.
ISSN:0045-6535
1879-1298
DOI:10.1016/j.chemosphere.2013.08.001