Susceptibility of coal to spontaneous combustion verified by modified adiabatic method under conditions of Ostrava–Karvina Coalfield, Czech Republic

The susceptibility of coal to spontaneous combustion is a physical–chemical property of coal that can be determined by a laboratory test. A number of laboratory methods verifying the coal susceptibility to spontaneous combustion exist, e.g. the oxidation method under adiabatic conditions, method acc...

Full description

Saved in:
Bibliographic Details
Published in:Fuel processing technology 2013-09, Vol.113, p.63-66
Main Authors: Zubíček, V., Adamus, A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c393t-940175a61616ca364db8b1d788ea2004e7039687abcfaf39f6b27aff07d553f23
cites cdi_FETCH-LOGICAL-c393t-940175a61616ca364db8b1d788ea2004e7039687abcfaf39f6b27aff07d553f23
container_end_page 66
container_issue
container_start_page 63
container_title Fuel processing technology
container_volume 113
creator Zubíček, V.
Adamus, A.
description The susceptibility of coal to spontaneous combustion is a physical–chemical property of coal that can be determined by a laboratory test. A number of laboratory methods verifying the coal susceptibility to spontaneous combustion exist, e.g. the oxidation method under adiabatic conditions, method according to the author Olpinski, method of pulse calorimetry, and CPT (Crossing Point Temperature) method. Any versatile method has not been so far developed, which would become a generally respected and utilized laboratory procedure of objective assessment. The paper deals with the verification of the widely used adiabatic oxidation method. The modification of the method in question consists in the adjustment of the test process by increasing the initial temperature. This procedure enables shortening the test process. Shortening the laboratory test duration creates conditions for wider utilization of the method in practice. The paper presents results of 36 tests of Ostrava–Karvina Coalfield coal samples which confirmed an applicability of the modified adiabatic method in practice. •We checked modified adiabatic method for self heating test of coal.•The novel aspects of the research - the modified adiabatic method was used first time in the Czech Republic.•The initial temperature of the method was increased to 120°C.•The time of the test was adjusted to 60minutes – parameter t60.•We tested 36 coal samples of Ostrava-Karvina Coalfield, Czech Republic.
doi_str_mv 10.1016/j.fuproc.2013.03.031
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1448718631</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0378382013001355</els_id><sourcerecordid>1448718631</sourcerecordid><originalsourceid>FETCH-LOGICAL-c393t-940175a61616ca364db8b1d788ea2004e7039687abcfaf39f6b27aff07d553f23</originalsourceid><addsrcrecordid>eNp9kd2K1TAUhYsoeBx9A8HcCF7Y407TNumNIIfxBwcGHOc67ObHyaFtapIeOF75DoIP6JOY0sFLyYaE8K29k7WK4jmFPQXavjnu7TIHr_YVULaHteiDYkcFZyWnQjwsdsC4KJmo4HHxJMYjADRNx3fF75slKjMn17vBpTPxliiPA0mexNlPCSfjl5jvxn6JyfmJnExw1hlN-jMZvd7OqB32mJwio0l3XpNl0iZk2aTdqopr4-uYAp7wz89fnzGc3ITkkEdl_aBfk8MPo-7IFzMv_eDU0-KRxSGaZ_f7RXH7_vLr4WN5df3h0-HdValYx1LZ1UB5gy3NSyFra92LnmouhMEKoDYcWNcKjr2yaFln277iaC1w3TTMVuyieLX1zfZ9X0xMcnTZj2HY_i1pXYvsYMtoRusNVcHHGIyVc3AjhrOkINcY5FFuMcg1BglrrbKX9xMwqvzbgJNy8Z-24qyDroLMvdg4i17it5CZ25vcqM1RtRzoSrzdCJMNOTkTZFTOTMpoF4xKUnv3_6f8BWMjrSU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1448718631</pqid></control><display><type>article</type><title>Susceptibility of coal to spontaneous combustion verified by modified adiabatic method under conditions of Ostrava–Karvina Coalfield, Czech Republic</title><source>ScienceDirect Journals</source><creator>Zubíček, V. ; Adamus, A.</creator><creatorcontrib>Zubíček, V. ; Adamus, A.</creatorcontrib><description>The susceptibility of coal to spontaneous combustion is a physical–chemical property of coal that can be determined by a laboratory test. A number of laboratory methods verifying the coal susceptibility to spontaneous combustion exist, e.g. the oxidation method under adiabatic conditions, method according to the author Olpinski, method of pulse calorimetry, and CPT (Crossing Point Temperature) method. Any versatile method has not been so far developed, which would become a generally respected and utilized laboratory procedure of objective assessment. The paper deals with the verification of the widely used adiabatic oxidation method. The modification of the method in question consists in the adjustment of the test process by increasing the initial temperature. This procedure enables shortening the test process. Shortening the laboratory test duration creates conditions for wider utilization of the method in practice. The paper presents results of 36 tests of Ostrava–Karvina Coalfield coal samples which confirmed an applicability of the modified adiabatic method in practice. •We checked modified adiabatic method for self heating test of coal.•The novel aspects of the research - the modified adiabatic method was used first time in the Czech Republic.•The initial temperature of the method was increased to 120°C.•The time of the test was adjusted to 60minutes – parameter t60.•We tested 36 coal samples of Ostrava-Karvina Coalfield, Czech Republic.</description><identifier>ISSN: 0378-3820</identifier><identifier>EISSN: 1873-7188</identifier><identifier>DOI: 10.1016/j.fuproc.2013.03.031</identifier><identifier>CODEN: FPTEDY</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Adiabatic conditions ; Adiabatic method ; Applied sciences ; calorimetry ; coal ; Coal and derived products ; combustion ; Energy ; Exact sciences and technology ; Fuels ; laboratory techniques ; Self heating ; Spontaneous combustion of coal ; Structure, chemical and physical properties ; Susceptibility ; temperature</subject><ispartof>Fuel processing technology, 2013-09, Vol.113, p.63-66</ispartof><rights>2013 Elsevier B.V.</rights><rights>2014 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c393t-940175a61616ca364db8b1d788ea2004e7039687abcfaf39f6b27aff07d553f23</citedby><cites>FETCH-LOGICAL-c393t-940175a61616ca364db8b1d788ea2004e7039687abcfaf39f6b27aff07d553f23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=27390920$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Zubíček, V.</creatorcontrib><creatorcontrib>Adamus, A.</creatorcontrib><title>Susceptibility of coal to spontaneous combustion verified by modified adiabatic method under conditions of Ostrava–Karvina Coalfield, Czech Republic</title><title>Fuel processing technology</title><description>The susceptibility of coal to spontaneous combustion is a physical–chemical property of coal that can be determined by a laboratory test. A number of laboratory methods verifying the coal susceptibility to spontaneous combustion exist, e.g. the oxidation method under adiabatic conditions, method according to the author Olpinski, method of pulse calorimetry, and CPT (Crossing Point Temperature) method. Any versatile method has not been so far developed, which would become a generally respected and utilized laboratory procedure of objective assessment. The paper deals with the verification of the widely used adiabatic oxidation method. The modification of the method in question consists in the adjustment of the test process by increasing the initial temperature. This procedure enables shortening the test process. Shortening the laboratory test duration creates conditions for wider utilization of the method in practice. The paper presents results of 36 tests of Ostrava–Karvina Coalfield coal samples which confirmed an applicability of the modified adiabatic method in practice. •We checked modified adiabatic method for self heating test of coal.•The novel aspects of the research - the modified adiabatic method was used first time in the Czech Republic.•The initial temperature of the method was increased to 120°C.•The time of the test was adjusted to 60minutes – parameter t60.•We tested 36 coal samples of Ostrava-Karvina Coalfield, Czech Republic.</description><subject>Adiabatic conditions</subject><subject>Adiabatic method</subject><subject>Applied sciences</subject><subject>calorimetry</subject><subject>coal</subject><subject>Coal and derived products</subject><subject>combustion</subject><subject>Energy</subject><subject>Exact sciences and technology</subject><subject>Fuels</subject><subject>laboratory techniques</subject><subject>Self heating</subject><subject>Spontaneous combustion of coal</subject><subject>Structure, chemical and physical properties</subject><subject>Susceptibility</subject><subject>temperature</subject><issn>0378-3820</issn><issn>1873-7188</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNp9kd2K1TAUhYsoeBx9A8HcCF7Y407TNumNIIfxBwcGHOc67ObHyaFtapIeOF75DoIP6JOY0sFLyYaE8K29k7WK4jmFPQXavjnu7TIHr_YVULaHteiDYkcFZyWnQjwsdsC4KJmo4HHxJMYjADRNx3fF75slKjMn17vBpTPxliiPA0mexNlPCSfjl5jvxn6JyfmJnExw1hlN-jMZvd7OqB32mJwio0l3XpNl0iZk2aTdqopr4-uYAp7wz89fnzGc3ITkkEdl_aBfk8MPo-7IFzMv_eDU0-KRxSGaZ_f7RXH7_vLr4WN5df3h0-HdValYx1LZ1UB5gy3NSyFra92LnmouhMEKoDYcWNcKjr2yaFln277iaC1w3TTMVuyieLX1zfZ9X0xMcnTZj2HY_i1pXYvsYMtoRusNVcHHGIyVc3AjhrOkINcY5FFuMcg1BglrrbKX9xMwqvzbgJNy8Z-24qyDroLMvdg4i17it5CZ25vcqM1RtRzoSrzdCJMNOTkTZFTOTMpoF4xKUnv3_6f8BWMjrSU</recordid><startdate>20130901</startdate><enddate>20130901</enddate><creator>Zubíček, V.</creator><creator>Adamus, A.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>FBQ</scope><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20130901</creationdate><title>Susceptibility of coal to spontaneous combustion verified by modified adiabatic method under conditions of Ostrava–Karvina Coalfield, Czech Republic</title><author>Zubíček, V. ; Adamus, A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c393t-940175a61616ca364db8b1d788ea2004e7039687abcfaf39f6b27aff07d553f23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Adiabatic conditions</topic><topic>Adiabatic method</topic><topic>Applied sciences</topic><topic>calorimetry</topic><topic>coal</topic><topic>Coal and derived products</topic><topic>combustion</topic><topic>Energy</topic><topic>Exact sciences and technology</topic><topic>Fuels</topic><topic>laboratory techniques</topic><topic>Self heating</topic><topic>Spontaneous combustion of coal</topic><topic>Structure, chemical and physical properties</topic><topic>Susceptibility</topic><topic>temperature</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zubíček, V.</creatorcontrib><creatorcontrib>Adamus, A.</creatorcontrib><collection>AGRIS</collection><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Fuel processing technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zubíček, V.</au><au>Adamus, A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Susceptibility of coal to spontaneous combustion verified by modified adiabatic method under conditions of Ostrava–Karvina Coalfield, Czech Republic</atitle><jtitle>Fuel processing technology</jtitle><date>2013-09-01</date><risdate>2013</risdate><volume>113</volume><spage>63</spage><epage>66</epage><pages>63-66</pages><issn>0378-3820</issn><eissn>1873-7188</eissn><coden>FPTEDY</coden><abstract>The susceptibility of coal to spontaneous combustion is a physical–chemical property of coal that can be determined by a laboratory test. A number of laboratory methods verifying the coal susceptibility to spontaneous combustion exist, e.g. the oxidation method under adiabatic conditions, method according to the author Olpinski, method of pulse calorimetry, and CPT (Crossing Point Temperature) method. Any versatile method has not been so far developed, which would become a generally respected and utilized laboratory procedure of objective assessment. The paper deals with the verification of the widely used adiabatic oxidation method. The modification of the method in question consists in the adjustment of the test process by increasing the initial temperature. This procedure enables shortening the test process. Shortening the laboratory test duration creates conditions for wider utilization of the method in practice. The paper presents results of 36 tests of Ostrava–Karvina Coalfield coal samples which confirmed an applicability of the modified adiabatic method in practice. •We checked modified adiabatic method for self heating test of coal.•The novel aspects of the research - the modified adiabatic method was used first time in the Czech Republic.•The initial temperature of the method was increased to 120°C.•The time of the test was adjusted to 60minutes – parameter t60.•We tested 36 coal samples of Ostrava-Karvina Coalfield, Czech Republic.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><doi>10.1016/j.fuproc.2013.03.031</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0378-3820
ispartof Fuel processing technology, 2013-09, Vol.113, p.63-66
issn 0378-3820
1873-7188
language eng
recordid cdi_proquest_miscellaneous_1448718631
source ScienceDirect Journals
subjects Adiabatic conditions
Adiabatic method
Applied sciences
calorimetry
coal
Coal and derived products
combustion
Energy
Exact sciences and technology
Fuels
laboratory techniques
Self heating
Spontaneous combustion of coal
Structure, chemical and physical properties
Susceptibility
temperature
title Susceptibility of coal to spontaneous combustion verified by modified adiabatic method under conditions of Ostrava–Karvina Coalfield, Czech Republic
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T15%3A53%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Susceptibility%20of%20coal%20to%20spontaneous%20combustion%20verified%20by%20modified%20adiabatic%20method%20under%20conditions%20of%20Ostrava%E2%80%93Karvina%20Coalfield,%20Czech%20Republic&rft.jtitle=Fuel%20processing%20technology&rft.au=Zub%C3%AD%C4%8Dek,%20V.&rft.date=2013-09-01&rft.volume=113&rft.spage=63&rft.epage=66&rft.pages=63-66&rft.issn=0378-3820&rft.eissn=1873-7188&rft.coden=FPTEDY&rft_id=info:doi/10.1016/j.fuproc.2013.03.031&rft_dat=%3Cproquest_cross%3E1448718631%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c393t-940175a61616ca364db8b1d788ea2004e7039687abcfaf39f6b27aff07d553f23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1448718631&rft_id=info:pmid/&rfr_iscdi=true