We used finite element (FE) method to investigate the effect of the drilling number and entry location of holes used in the multiple drilling technique on the stress and strain state in femur. Different three-dimensional FE models of a human hip joint with or without multiple drilling were fabricate...

Full description

Saved in:
Bibliographic Details
Published in:Annals of biomedical engineering 2013-12, Vol.41 (12), p.2528-2537
Main Authors: Bae, Ji Yong, Kwak, Dai Soon, Park, Kyung Soon, Jeon, Insu
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We used finite element (FE) method to investigate the effect of the drilling number and entry location of holes used in the multiple drilling technique on the stress and strain state in femur. Different three-dimensional FE models of a human hip joint with or without multiple drilling were fabricated using computed tomographic images obtained from the hip joint of a cadaver. The analysis technique was evaluated in a compression test using the cadaver specimen and FE analysis for the test using an FE model of the specimen. Von Mises stresses, principal stresses, and principal strains in the cancellous and cortical bone were calculated by using the different models, and changes in these values in relation to drilling number and entry hole locations were evaluated. Calculated peak values were much smaller than the yield strength, tensile strength, and yield strain of the cancellous and cortical bone for all cases of multiple drilling. Our results support that the multiple drilling technique for osteonecrosis of the femoral head is a stable operation technique.
ISSN:0090-6964
1573-9686
DOI:10.1007/s10439-013-0851-1