Assessing the thermal insulation of old buildings—The need for in situ spot measurements of thermal resistance and planar infrared thermography

This article reports on a methodology to determine the level of thermal insulation in old buildings through spot measurements of thermal resistance and planar infrared thermography. An old building due for renovation is used as a test case and the two methods are combined in order to obtain a total...

Full description

Saved in:
Bibliographic Details
Published in:Energy conversion and management 1998, Vol.39 (1), p.65-79
Main Authors: Haralambopoulos, D.A., Paparsenos, G.F.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c367t-c733da341436b7880d5775e6a1974c8f1ec49ec836ef1b3e31288bc6f9345cc93
cites cdi_FETCH-LOGICAL-c367t-c733da341436b7880d5775e6a1974c8f1ec49ec836ef1b3e31288bc6f9345cc93
container_end_page 79
container_issue 1
container_start_page 65
container_title Energy conversion and management
container_volume 39
creator Haralambopoulos, D.A.
Paparsenos, G.F.
description This article reports on a methodology to determine the level of thermal insulation in old buildings through spot measurements of thermal resistance and planar infrared thermography. An old building due for renovation is used as a test case and the two methods are combined in order to obtain a total view of the building envelope. The existence of the thermal leaks on the building shell are documented and are quantified through the synchronous use of the results from spot measurements and infrared thermography analysis. The methodology proposed proves to be reliable and can also be used for non-destructive tests of the thermal characteristics of new buildings, or old buildings after renovation.
doi_str_mv 10.1016/S0196-8904(96)00176-8
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_14516022</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0196890496001768</els_id><sourcerecordid>14516022</sourcerecordid><originalsourceid>FETCH-LOGICAL-c367t-c733da341436b7880d5775e6a1974c8f1ec49ec836ef1b3e31288bc6f9345cc93</originalsourceid><addsrcrecordid>eNqFkc9qFTEUxoMoeK0-gpCFFLuYmkxmksyqlFLbQsGFdR1yM2fayEwy5mQK3fUVCj6hT2Lm3tqti3AI_L7v_PkI-cjZMWdcfvnOeCcr3bHmcyePGOOq_F6RDdeqq-q6Vq_J5gV5S94h_mSMiZbJDXk6RQREH25pvoP1pcmO1AdcRpt9DDQONI493S5-7AuGfx5_3xQyAPR0iKmgFH1eKM4x0wksLgkmCBlX5T-_BOgx2-CA2tDTebTBrtIh2VR8dli8TXa-e3hP3gx2RPjwXA_Ij6_nN2eX1fW3i6uz0-vKCaly5ZQQvRUNb4TcKq1Z3yrVgrS8U43TAwfXdOC0kDDwrQDBa623Tg6daFrnOnFADve-c4q_FsBsJo8OxjIaxAUNb1ouWV0XsN2DLkXEBIOZk59sejCcmTUAswvArNc1pe4CMLroPj03sOjsWFYNzuOLuOY1b8WKnewxKMvee0gGnYdyqd4ncNn00f-n0V93CJ5e</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>14516022</pqid></control><display><type>article</type><title>Assessing the thermal insulation of old buildings—The need for in situ spot measurements of thermal resistance and planar infrared thermography</title><source>ScienceDirect Freedom Collection</source><creator>Haralambopoulos, D.A. ; Paparsenos, G.F.</creator><creatorcontrib>Haralambopoulos, D.A. ; Paparsenos, G.F.</creatorcontrib><description>This article reports on a methodology to determine the level of thermal insulation in old buildings through spot measurements of thermal resistance and planar infrared thermography. An old building due for renovation is used as a test case and the two methods are combined in order to obtain a total view of the building envelope. The existence of the thermal leaks on the building shell are documented and are quantified through the synchronous use of the results from spot measurements and infrared thermography analysis. The methodology proposed proves to be reliable and can also be used for non-destructive tests of the thermal characteristics of new buildings, or old buildings after renovation.</description><identifier>ISSN: 0196-8904</identifier><identifier>EISSN: 1879-2227</identifier><identifier>DOI: 10.1016/S0196-8904(96)00176-8</identifier><identifier>CODEN: ECMADL</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Applied sciences ; Building ; Building insulation ; Buildings ; Buildings. Public works ; Energy ; Energy. Thermal use of fuels ; Envelope ; Exact sciences and technology ; External envelopes ; Infrared thermography ; Measurement ; Rational use of energy: conservation and recovery of energy ; Thermal insulation</subject><ispartof>Energy conversion and management, 1998, Vol.39 (1), p.65-79</ispartof><rights>1997</rights><rights>1998 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c367t-c733da341436b7880d5775e6a1974c8f1ec49ec836ef1b3e31288bc6f9345cc93</citedby><cites>FETCH-LOGICAL-c367t-c733da341436b7880d5775e6a1974c8f1ec49ec836ef1b3e31288bc6f9345cc93</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4024,27923,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=2121538$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Haralambopoulos, D.A.</creatorcontrib><creatorcontrib>Paparsenos, G.F.</creatorcontrib><title>Assessing the thermal insulation of old buildings—The need for in situ spot measurements of thermal resistance and planar infrared thermography</title><title>Energy conversion and management</title><description>This article reports on a methodology to determine the level of thermal insulation in old buildings through spot measurements of thermal resistance and planar infrared thermography. An old building due for renovation is used as a test case and the two methods are combined in order to obtain a total view of the building envelope. The existence of the thermal leaks on the building shell are documented and are quantified through the synchronous use of the results from spot measurements and infrared thermography analysis. The methodology proposed proves to be reliable and can also be used for non-destructive tests of the thermal characteristics of new buildings, or old buildings after renovation.</description><subject>Applied sciences</subject><subject>Building</subject><subject>Building insulation</subject><subject>Buildings</subject><subject>Buildings. Public works</subject><subject>Energy</subject><subject>Energy. Thermal use of fuels</subject><subject>Envelope</subject><subject>Exact sciences and technology</subject><subject>External envelopes</subject><subject>Infrared thermography</subject><subject>Measurement</subject><subject>Rational use of energy: conservation and recovery of energy</subject><subject>Thermal insulation</subject><issn>0196-8904</issn><issn>1879-2227</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNqFkc9qFTEUxoMoeK0-gpCFFLuYmkxmksyqlFLbQsGFdR1yM2fayEwy5mQK3fUVCj6hT2Lm3tqti3AI_L7v_PkI-cjZMWdcfvnOeCcr3bHmcyePGOOq_F6RDdeqq-q6Vq_J5gV5S94h_mSMiZbJDXk6RQREH25pvoP1pcmO1AdcRpt9DDQONI493S5-7AuGfx5_3xQyAPR0iKmgFH1eKM4x0wksLgkmCBlX5T-_BOgx2-CA2tDTebTBrtIh2VR8dli8TXa-e3hP3gx2RPjwXA_Ij6_nN2eX1fW3i6uz0-vKCaly5ZQQvRUNb4TcKq1Z3yrVgrS8U43TAwfXdOC0kDDwrQDBa623Tg6daFrnOnFADve-c4q_FsBsJo8OxjIaxAUNb1ouWV0XsN2DLkXEBIOZk59sejCcmTUAswvArNc1pe4CMLroPj03sOjsWFYNzuOLuOY1b8WKnewxKMvee0gGnYdyqd4ncNn00f-n0V93CJ5e</recordid><startdate>1998</startdate><enddate>1998</enddate><creator>Haralambopoulos, D.A.</creator><creator>Paparsenos, G.F.</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope></search><sort><creationdate>1998</creationdate><title>Assessing the thermal insulation of old buildings—The need for in situ spot measurements of thermal resistance and planar infrared thermography</title><author>Haralambopoulos, D.A. ; Paparsenos, G.F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c367t-c733da341436b7880d5775e6a1974c8f1ec49ec836ef1b3e31288bc6f9345cc93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Applied sciences</topic><topic>Building</topic><topic>Building insulation</topic><topic>Buildings</topic><topic>Buildings. Public works</topic><topic>Energy</topic><topic>Energy. Thermal use of fuels</topic><topic>Envelope</topic><topic>Exact sciences and technology</topic><topic>External envelopes</topic><topic>Infrared thermography</topic><topic>Measurement</topic><topic>Rational use of energy: conservation and recovery of energy</topic><topic>Thermal insulation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Haralambopoulos, D.A.</creatorcontrib><creatorcontrib>Paparsenos, G.F.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><jtitle>Energy conversion and management</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Haralambopoulos, D.A.</au><au>Paparsenos, G.F.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Assessing the thermal insulation of old buildings—The need for in situ spot measurements of thermal resistance and planar infrared thermography</atitle><jtitle>Energy conversion and management</jtitle><date>1998</date><risdate>1998</risdate><volume>39</volume><issue>1</issue><spage>65</spage><epage>79</epage><pages>65-79</pages><issn>0196-8904</issn><eissn>1879-2227</eissn><coden>ECMADL</coden><abstract>This article reports on a methodology to determine the level of thermal insulation in old buildings through spot measurements of thermal resistance and planar infrared thermography. An old building due for renovation is used as a test case and the two methods are combined in order to obtain a total view of the building envelope. The existence of the thermal leaks on the building shell are documented and are quantified through the synchronous use of the results from spot measurements and infrared thermography analysis. The methodology proposed proves to be reliable and can also be used for non-destructive tests of the thermal characteristics of new buildings, or old buildings after renovation.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/S0196-8904(96)00176-8</doi><tpages>15</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0196-8904
ispartof Energy conversion and management, 1998, Vol.39 (1), p.65-79
issn 0196-8904
1879-2227
language eng
recordid cdi_proquest_miscellaneous_14516022
source ScienceDirect Freedom Collection
subjects Applied sciences
Building
Building insulation
Buildings
Buildings. Public works
Energy
Energy. Thermal use of fuels
Envelope
Exact sciences and technology
External envelopes
Infrared thermography
Measurement
Rational use of energy: conservation and recovery of energy
Thermal insulation
title Assessing the thermal insulation of old buildings—The need for in situ spot measurements of thermal resistance and planar infrared thermography
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T06%3A39%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Assessing%20the%20thermal%20insulation%20of%20old%20buildings%E2%80%94The%20need%20for%20in%20situ%20spot%20measurements%20of%20thermal%20resistance%20and%20planar%20infrared%20thermography&rft.jtitle=Energy%20conversion%20and%20management&rft.au=Haralambopoulos,%20D.A.&rft.date=1998&rft.volume=39&rft.issue=1&rft.spage=65&rft.epage=79&rft.pages=65-79&rft.issn=0196-8904&rft.eissn=1879-2227&rft.coden=ECMADL&rft_id=info:doi/10.1016/S0196-8904(96)00176-8&rft_dat=%3Cproquest_cross%3E14516022%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c367t-c733da341436b7880d5775e6a1974c8f1ec49ec836ef1b3e31288bc6f9345cc93%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=14516022&rft_id=info:pmid/&rfr_iscdi=true