Loading…

Transjugular Tricuspid Valve-in-Valve Implantation

A 60 year-old female underwent tricuspid valve replacement in 2002. Post-operative recovery was complicated by severe post-pericardiotomy-syndrome. Seven years later she underwent transcatheter valve-in-valve implantation through the right jugular vein because of early prosthesis deterioration. More...

Full description

Saved in:
Bibliographic Details
Published in:Heart, lung & circulation lung & circulation, 2013-12, Vol.22 (12), p.1036-1039
Main Authors: Salizzoni, Stefano, MD, La Torre, Michele, MD, Barbero, Cristina, MD, Marra, Walter Grosso, MD, Moretti, Claudio, MD, D’Amico, Maurizio, MD, Rinaldi, Mauro, MD
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A 60 year-old female underwent tricuspid valve replacement in 2002. Post-operative recovery was complicated by severe post-pericardiotomy-syndrome. Seven years later she underwent transcatheter valve-in-valve implantation through the right jugular vein because of early prosthesis deterioration. Moreover intra-operative transoesophageal echocardiography showed an important right-to-left shunt through the patent foramen ovale that immediately disappeared after the deployment of a 29-mm Sapien-XT. The patient had an immediate and dramatic improvement in day-by-day activities. This case shows that tricuspid valve deterioration can be safely and successfully treated through this approach.