Modeling and comparative thermal performance of ground air collector and earth air heat exchanger for heating of greenhouse
The potential of using the stored thermal energy of ground for space heating has been investigated with the help of two buried pipe systems, i.e., ground air collector and earth air heat exchanger, integrated with the greenhouse located in the premises of Indian Institute of Technology, Delhi, India...
Saved in:
Published in: | Energy and buildings 2005-06, Vol.37 (6), p.613-621 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c370t-21295973cad72a177e1eae405bd532eb76f4f70fd2916dfa29f2dbb280a009ae3 |
---|---|
cites | cdi_FETCH-LOGICAL-c370t-21295973cad72a177e1eae405bd532eb76f4f70fd2916dfa29f2dbb280a009ae3 |
container_end_page | 621 |
container_issue | 6 |
container_start_page | 613 |
container_title | Energy and buildings |
container_volume | 37 |
creator | Ghosal, M.K. Tiwari, G.N. Das, D.K. Pandey, K.P. |
description | The potential of using the stored thermal energy of ground for space heating has been investigated with the help of two buried pipe systems, i.e., ground air collector and earth air heat exchanger, integrated with the greenhouse located in the premises of Indian Institute of Technology, Delhi, India. The total length of the buried pipes in both the arrangements was kept same for making a comparative study. A complete numerical model has been developed to predict and compare their thermal performance for choosing a suitable heating method in the composite climate of India. Experiments were conducted extensively during winter period from November 2002 to March 2003, but the model was validated against the clear and sunny days. Performance of these two arrangements was compared in terms of thermal load leveling and total heating potential. Temperatures of greenhouse air with ground air collector were observed to be 2–3
°C higher than those with earth air heat exchanger. The temperature fluctuations of greenhouse air were also less when operated with ground air collector as compared to earth air heat exchanger. Predicted and computed values of greenhouse air temperatures in both the systems exhibited fair agreement. Finally ground air collector was chosen as a suitable option for heating of greenhouse in the above climate. |
doi_str_mv | 10.1016/j.enbuild.2004.09.004 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_14733893</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0378778804003007</els_id><sourcerecordid>14733893</sourcerecordid><originalsourceid>FETCH-LOGICAL-c370t-21295973cad72a177e1eae405bd532eb76f4f70fd2916dfa29f2dbb280a009ae3</originalsourceid><addsrcrecordid>eNqFkM1P4zAQxXNYpC2wf8JKucCt2bHT1PEJoYqPlYq4wNma2OPGlRsXO0Wg_efX_ZA4cnrW6L15419R_GZQMWDzP-uKhm7nvKk4wKwCWWX5UUygFu1UiLb9WZyntAaAeSPYpPj3FAx5N6xKHEypw2aLEUf3TuXYU9ygL7cUbcivQVMZbLmKYZed6GJ2e096DPGQJYxjf5j3hGNJH7rHYUWxzOnDaF9yWEA09GGX6LI4s-gT_TrpRfF6f_eyeJwunx_-Lm6XU10LGKeccdlIUWs0giMTghghzaDpTFNz6sTczqwAa7hkc2ORS8tN1_EWEEAi1RfF9XHvNoa3HaVRbVzS5D0OlO9QbCbqupV1NjZHo44hpUhWbaPbYPxUDNQer1qrE161x6tAqiw5d3UqwKTR25hhufQVzqibVjbZd3P0Uf7tu6OoknaUwRoXM0hlgvum6T_yrJgC</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>14733893</pqid></control><display><type>article</type><title>Modeling and comparative thermal performance of ground air collector and earth air heat exchanger for heating of greenhouse</title><source>ScienceDirect Freedom Collection</source><creator>Ghosal, M.K. ; Tiwari, G.N. ; Das, D.K. ; Pandey, K.P.</creator><creatorcontrib>Ghosal, M.K. ; Tiwari, G.N. ; Das, D.K. ; Pandey, K.P.</creatorcontrib><description>The potential of using the stored thermal energy of ground for space heating has been investigated with the help of two buried pipe systems, i.e., ground air collector and earth air heat exchanger, integrated with the greenhouse located in the premises of Indian Institute of Technology, Delhi, India. The total length of the buried pipes in both the arrangements was kept same for making a comparative study. A complete numerical model has been developed to predict and compare their thermal performance for choosing a suitable heating method in the composite climate of India. Experiments were conducted extensively during winter period from November 2002 to March 2003, but the model was validated against the clear and sunny days. Performance of these two arrangements was compared in terms of thermal load leveling and total heating potential. Temperatures of greenhouse air with ground air collector were observed to be 2–3
°C higher than those with earth air heat exchanger. The temperature fluctuations of greenhouse air were also less when operated with ground air collector as compared to earth air heat exchanger. Predicted and computed values of greenhouse air temperatures in both the systems exhibited fair agreement. Finally ground air collector was chosen as a suitable option for heating of greenhouse in the above climate.</description><identifier>ISSN: 0378-7788</identifier><identifier>DOI: 10.1016/j.enbuild.2004.09.004</identifier><identifier>CODEN: ENEBDR</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Agricultural facility (building and storage) ; Applied sciences ; Building technical equipments ; Buildings ; Buildings. Public works ; Earth air heat exchanger ; Environmental engineering ; Exact sciences and technology ; Greenhouse ; Ground air collector ; Modeling ; Solar energy ; Thermal load leveling ; Types of buildings ; Ventilation. Air conditioning</subject><ispartof>Energy and buildings, 2005-06, Vol.37 (6), p.613-621</ispartof><rights>2004 Elsevier B.V.</rights><rights>2005 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c370t-21295973cad72a177e1eae405bd532eb76f4f70fd2916dfa29f2dbb280a009ae3</citedby><cites>FETCH-LOGICAL-c370t-21295973cad72a177e1eae405bd532eb76f4f70fd2916dfa29f2dbb280a009ae3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=16575895$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Ghosal, M.K.</creatorcontrib><creatorcontrib>Tiwari, G.N.</creatorcontrib><creatorcontrib>Das, D.K.</creatorcontrib><creatorcontrib>Pandey, K.P.</creatorcontrib><title>Modeling and comparative thermal performance of ground air collector and earth air heat exchanger for heating of greenhouse</title><title>Energy and buildings</title><description>The potential of using the stored thermal energy of ground for space heating has been investigated with the help of two buried pipe systems, i.e., ground air collector and earth air heat exchanger, integrated with the greenhouse located in the premises of Indian Institute of Technology, Delhi, India. The total length of the buried pipes in both the arrangements was kept same for making a comparative study. A complete numerical model has been developed to predict and compare their thermal performance for choosing a suitable heating method in the composite climate of India. Experiments were conducted extensively during winter period from November 2002 to March 2003, but the model was validated against the clear and sunny days. Performance of these two arrangements was compared in terms of thermal load leveling and total heating potential. Temperatures of greenhouse air with ground air collector were observed to be 2–3
°C higher than those with earth air heat exchanger. The temperature fluctuations of greenhouse air were also less when operated with ground air collector as compared to earth air heat exchanger. Predicted and computed values of greenhouse air temperatures in both the systems exhibited fair agreement. Finally ground air collector was chosen as a suitable option for heating of greenhouse in the above climate.</description><subject>Agricultural facility (building and storage)</subject><subject>Applied sciences</subject><subject>Building technical equipments</subject><subject>Buildings</subject><subject>Buildings. Public works</subject><subject>Earth air heat exchanger</subject><subject>Environmental engineering</subject><subject>Exact sciences and technology</subject><subject>Greenhouse</subject><subject>Ground air collector</subject><subject>Modeling</subject><subject>Solar energy</subject><subject>Thermal load leveling</subject><subject>Types of buildings</subject><subject>Ventilation. Air conditioning</subject><issn>0378-7788</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNqFkM1P4zAQxXNYpC2wf8JKucCt2bHT1PEJoYqPlYq4wNma2OPGlRsXO0Wg_efX_ZA4cnrW6L15419R_GZQMWDzP-uKhm7nvKk4wKwCWWX5UUygFu1UiLb9WZyntAaAeSPYpPj3FAx5N6xKHEypw2aLEUf3TuXYU9ygL7cUbcivQVMZbLmKYZed6GJ2e096DPGQJYxjf5j3hGNJH7rHYUWxzOnDaF9yWEA09GGX6LI4s-gT_TrpRfF6f_eyeJwunx_-Lm6XU10LGKeccdlIUWs0giMTghghzaDpTFNz6sTczqwAa7hkc2ORS8tN1_EWEEAi1RfF9XHvNoa3HaVRbVzS5D0OlO9QbCbqupV1NjZHo44hpUhWbaPbYPxUDNQer1qrE161x6tAqiw5d3UqwKTR25hhufQVzqibVjbZd3P0Uf7tu6OoknaUwRoXM0hlgvum6T_yrJgC</recordid><startdate>20050601</startdate><enddate>20050601</enddate><creator>Ghosal, M.K.</creator><creator>Tiwari, G.N.</creator><creator>Das, D.K.</creator><creator>Pandey, K.P.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope></search><sort><creationdate>20050601</creationdate><title>Modeling and comparative thermal performance of ground air collector and earth air heat exchanger for heating of greenhouse</title><author>Ghosal, M.K. ; Tiwari, G.N. ; Das, D.K. ; Pandey, K.P.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c370t-21295973cad72a177e1eae405bd532eb76f4f70fd2916dfa29f2dbb280a009ae3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Agricultural facility (building and storage)</topic><topic>Applied sciences</topic><topic>Building technical equipments</topic><topic>Buildings</topic><topic>Buildings. Public works</topic><topic>Earth air heat exchanger</topic><topic>Environmental engineering</topic><topic>Exact sciences and technology</topic><topic>Greenhouse</topic><topic>Ground air collector</topic><topic>Modeling</topic><topic>Solar energy</topic><topic>Thermal load leveling</topic><topic>Types of buildings</topic><topic>Ventilation. Air conditioning</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ghosal, M.K.</creatorcontrib><creatorcontrib>Tiwari, G.N.</creatorcontrib><creatorcontrib>Das, D.K.</creatorcontrib><creatorcontrib>Pandey, K.P.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><jtitle>Energy and buildings</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ghosal, M.K.</au><au>Tiwari, G.N.</au><au>Das, D.K.</au><au>Pandey, K.P.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Modeling and comparative thermal performance of ground air collector and earth air heat exchanger for heating of greenhouse</atitle><jtitle>Energy and buildings</jtitle><date>2005-06-01</date><risdate>2005</risdate><volume>37</volume><issue>6</issue><spage>613</spage><epage>621</epage><pages>613-621</pages><issn>0378-7788</issn><coden>ENEBDR</coden><abstract>The potential of using the stored thermal energy of ground for space heating has been investigated with the help of two buried pipe systems, i.e., ground air collector and earth air heat exchanger, integrated with the greenhouse located in the premises of Indian Institute of Technology, Delhi, India. The total length of the buried pipes in both the arrangements was kept same for making a comparative study. A complete numerical model has been developed to predict and compare their thermal performance for choosing a suitable heating method in the composite climate of India. Experiments were conducted extensively during winter period from November 2002 to March 2003, but the model was validated against the clear and sunny days. Performance of these two arrangements was compared in terms of thermal load leveling and total heating potential. Temperatures of greenhouse air with ground air collector were observed to be 2–3
°C higher than those with earth air heat exchanger. The temperature fluctuations of greenhouse air were also less when operated with ground air collector as compared to earth air heat exchanger. Predicted and computed values of greenhouse air temperatures in both the systems exhibited fair agreement. Finally ground air collector was chosen as a suitable option for heating of greenhouse in the above climate.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><doi>10.1016/j.enbuild.2004.09.004</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0378-7788 |
ispartof | Energy and buildings, 2005-06, Vol.37 (6), p.613-621 |
issn | 0378-7788 |
language | eng |
recordid | cdi_proquest_miscellaneous_14733893 |
source | ScienceDirect Freedom Collection |
subjects | Agricultural facility (building and storage) Applied sciences Building technical equipments Buildings Buildings. Public works Earth air heat exchanger Environmental engineering Exact sciences and technology Greenhouse Ground air collector Modeling Solar energy Thermal load leveling Types of buildings Ventilation. Air conditioning |
title | Modeling and comparative thermal performance of ground air collector and earth air heat exchanger for heating of greenhouse |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T10%3A34%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Modeling%20and%20comparative%20thermal%20performance%20of%20ground%20air%20collector%20and%20earth%20air%20heat%20exchanger%20for%20heating%20of%20greenhouse&rft.jtitle=Energy%20and%20buildings&rft.au=Ghosal,%20M.K.&rft.date=2005-06-01&rft.volume=37&rft.issue=6&rft.spage=613&rft.epage=621&rft.pages=613-621&rft.issn=0378-7788&rft.coden=ENEBDR&rft_id=info:doi/10.1016/j.enbuild.2004.09.004&rft_dat=%3Cproquest_cross%3E14733893%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c370t-21295973cad72a177e1eae405bd532eb76f4f70fd2916dfa29f2dbb280a009ae3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=14733893&rft_id=info:pmid/&rfr_iscdi=true |