Frequency‐of‐Occurrence Monitoring for Coliform Bacteria in Small Water Systems
The effectiveness of Clark's presence–absence (P–A) test was compared with that of the membrane filter (MF) technique during an evaluation of the frequency‐of‐occurrence approach to microbiological monitoring of water systems. Results showed no significant difference between the fractions that...
Saved in:
Published in: | Journal - American Water Works Association 1987-11, Vol.79 (11), p.59-63 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c3504-df587bca3815f14ec800198def1b7548ed399ba62e626eb58ad7d0b7719986e53 |
---|---|
cites | cdi_FETCH-LOGICAL-c3504-df587bca3815f14ec800198def1b7548ed399ba62e626eb58ad7d0b7719986e53 |
container_end_page | 63 |
container_issue | 11 |
container_start_page | 59 |
container_title | Journal - American Water Works Association |
container_volume | 79 |
creator | Pipes, Wesley O. Mueller, Karolyn Troy, Marleen Minnigh, Harvey A. |
description | The effectiveness of Clark's presence–absence (P–A) test was compared with that of the membrane filter (MF) technique during an evaluation of the frequency‐of‐occurrence approach to microbiological monitoring of water systems. Results showed no significant difference between the fractions that were positive by the two methods. Major changes in the microbiological quality of the water were detected with equal frequency by the P–A test and the MF method and were detected more readily by the frequency‐of‐occurrence parameter than by the average MF coliform count. |
doi_str_mv | 10.1002/j.1551-8833.1987.tb02944.x |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_14835499</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>14835499</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3504-df587bca3815f14ec800198def1b7548ed399ba62e626eb58ad7d0b7719986e53</originalsourceid><addsrcrecordid>eNqVkEtOwzAQhi0EEqVwB4sFuwS7thObXagoIBV1UVDZWY7jIFd5FDsVzY4jcEZOgkMr9mzm_Y9mPgAuMYoxQpPrdYwZwxHnhMRY8DTucjQRlMa7IzD6ax2DEUKIRJih11Nw5v06pJhhOgLLmTPvW9Po_vvzqy2DWWi9dS5UDHxqG9u1zjZvsGwdnLaVDb6Gt0p3xlkFbQOXtaoquFKhAJe970ztz8FJqSpvLg5-DF5md8_Th2i-uH-cZvNIE4ZoVJSMp7lWhGNWYmo0D0cJXpgS5ymj3BREiFwlE5NMEpMzroq0QHmaYiF4YhgZg6v93o1rww--k7X12lSVaky79RJTThgVIgze7Ae1a713ppQbZ2vleomRHDjKtRxgyQGWHDjKA0e5C-JsL_6wlen_oZTZapX9xuQHHWV-Og</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>14835499</pqid></control><display><type>article</type><title>Frequency‐of‐Occurrence Monitoring for Coliform Bacteria in Small Water Systems</title><source>JSTOR Archival Journals and Primary Sources Collection</source><creator>Pipes, Wesley O. ; Mueller, Karolyn ; Troy, Marleen ; Minnigh, Harvey A.</creator><creatorcontrib>Pipes, Wesley O. ; Mueller, Karolyn ; Troy, Marleen ; Minnigh, Harvey A.</creatorcontrib><description>The effectiveness of Clark's presence–absence (P–A) test was compared with that of the membrane filter (MF) technique during an evaluation of the frequency‐of‐occurrence approach to microbiological monitoring of water systems. Results showed no significant difference between the fractions that were positive by the two methods. Major changes in the microbiological quality of the water were detected with equal frequency by the P–A test and the MF method and were detected more readily by the frequency‐of‐occurrence parameter than by the average MF coliform count.</description><identifier>ISSN: 0003-150X</identifier><identifier>EISSN: 1551-8833</identifier><identifier>DOI: 10.1002/j.1551-8833.1987.tb02944.x</identifier><language>eng</language><subject>Bacteria ; Coliforms ; Membrane Filter Technique ; Microbiological Analyses ; Presence‐Absence Test ; Small Water Systems ; Water Quality Monitoring</subject><ispartof>Journal - American Water Works Association, 1987-11, Vol.79 (11), p.59-63</ispartof><rights>1987 American Water Works Association</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3504-df587bca3815f14ec800198def1b7548ed399ba62e626eb58ad7d0b7719986e53</citedby><cites>FETCH-LOGICAL-c3504-df587bca3815f14ec800198def1b7548ed399ba62e626eb58ad7d0b7719986e53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Pipes, Wesley O.</creatorcontrib><creatorcontrib>Mueller, Karolyn</creatorcontrib><creatorcontrib>Troy, Marleen</creatorcontrib><creatorcontrib>Minnigh, Harvey A.</creatorcontrib><title>Frequency‐of‐Occurrence Monitoring for Coliform Bacteria in Small Water Systems</title><title>Journal - American Water Works Association</title><description>The effectiveness of Clark's presence–absence (P–A) test was compared with that of the membrane filter (MF) technique during an evaluation of the frequency‐of‐occurrence approach to microbiological monitoring of water systems. Results showed no significant difference between the fractions that were positive by the two methods. Major changes in the microbiological quality of the water were detected with equal frequency by the P–A test and the MF method and were detected more readily by the frequency‐of‐occurrence parameter than by the average MF coliform count.</description><subject>Bacteria</subject><subject>Coliforms</subject><subject>Membrane Filter Technique</subject><subject>Microbiological Analyses</subject><subject>Presence‐Absence Test</subject><subject>Small Water Systems</subject><subject>Water Quality Monitoring</subject><issn>0003-150X</issn><issn>1551-8833</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1987</creationdate><recordtype>article</recordtype><recordid>eNqVkEtOwzAQhi0EEqVwB4sFuwS7thObXagoIBV1UVDZWY7jIFd5FDsVzY4jcEZOgkMr9mzm_Y9mPgAuMYoxQpPrdYwZwxHnhMRY8DTucjQRlMa7IzD6ax2DEUKIRJih11Nw5v06pJhhOgLLmTPvW9Po_vvzqy2DWWi9dS5UDHxqG9u1zjZvsGwdnLaVDb6Gt0p3xlkFbQOXtaoquFKhAJe970ztz8FJqSpvLg5-DF5md8_Th2i-uH-cZvNIE4ZoVJSMp7lWhGNWYmo0D0cJXpgS5ymj3BREiFwlE5NMEpMzroq0QHmaYiF4YhgZg6v93o1rww--k7X12lSVaky79RJTThgVIgze7Ae1a713ppQbZ2vleomRHDjKtRxgyQGWHDjKA0e5C-JsL_6wlen_oZTZapX9xuQHHWV-Og</recordid><startdate>198711</startdate><enddate>198711</enddate><creator>Pipes, Wesley O.</creator><creator>Mueller, Karolyn</creator><creator>Troy, Marleen</creator><creator>Minnigh, Harvey A.</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7TV</scope><scope>C1K</scope></search><sort><creationdate>198711</creationdate><title>Frequency‐of‐Occurrence Monitoring for Coliform Bacteria in Small Water Systems</title><author>Pipes, Wesley O. ; Mueller, Karolyn ; Troy, Marleen ; Minnigh, Harvey A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3504-df587bca3815f14ec800198def1b7548ed399ba62e626eb58ad7d0b7719986e53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1987</creationdate><topic>Bacteria</topic><topic>Coliforms</topic><topic>Membrane Filter Technique</topic><topic>Microbiological Analyses</topic><topic>Presence‐Absence Test</topic><topic>Small Water Systems</topic><topic>Water Quality Monitoring</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pipes, Wesley O.</creatorcontrib><creatorcontrib>Mueller, Karolyn</creatorcontrib><creatorcontrib>Troy, Marleen</creatorcontrib><creatorcontrib>Minnigh, Harvey A.</creatorcontrib><collection>CrossRef</collection><collection>Pollution Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><jtitle>Journal - American Water Works Association</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pipes, Wesley O.</au><au>Mueller, Karolyn</au><au>Troy, Marleen</au><au>Minnigh, Harvey A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Frequency‐of‐Occurrence Monitoring for Coliform Bacteria in Small Water Systems</atitle><jtitle>Journal - American Water Works Association</jtitle><date>1987-11</date><risdate>1987</risdate><volume>79</volume><issue>11</issue><spage>59</spage><epage>63</epage><pages>59-63</pages><issn>0003-150X</issn><eissn>1551-8833</eissn><abstract>The effectiveness of Clark's presence–absence (P–A) test was compared with that of the membrane filter (MF) technique during an evaluation of the frequency‐of‐occurrence approach to microbiological monitoring of water systems. Results showed no significant difference between the fractions that were positive by the two methods. Major changes in the microbiological quality of the water were detected with equal frequency by the P–A test and the MF method and were detected more readily by the frequency‐of‐occurrence parameter than by the average MF coliform count.</abstract><doi>10.1002/j.1551-8833.1987.tb02944.x</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-150X |
ispartof | Journal - American Water Works Association, 1987-11, Vol.79 (11), p.59-63 |
issn | 0003-150X 1551-8833 |
language | eng |
recordid | cdi_proquest_miscellaneous_14835499 |
source | JSTOR Archival Journals and Primary Sources Collection |
subjects | Bacteria Coliforms Membrane Filter Technique Microbiological Analyses Presence‐Absence Test Small Water Systems Water Quality Monitoring |
title | Frequency‐of‐Occurrence Monitoring for Coliform Bacteria in Small Water Systems |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T14%3A55%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Frequency%E2%80%90of%E2%80%90Occurrence%20Monitoring%20for%20Coliform%20Bacteria%20in%20Small%20Water%20Systems&rft.jtitle=Journal%20-%20American%20Water%20Works%20Association&rft.au=Pipes,%20Wesley%20O.&rft.date=1987-11&rft.volume=79&rft.issue=11&rft.spage=59&rft.epage=63&rft.pages=59-63&rft.issn=0003-150X&rft.eissn=1551-8833&rft_id=info:doi/10.1002/j.1551-8833.1987.tb02944.x&rft_dat=%3Cproquest_cross%3E14835499%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3504-df587bca3815f14ec800198def1b7548ed399ba62e626eb58ad7d0b7719986e53%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=14835499&rft_id=info:pmid/&rfr_iscdi=true |