Ultrasound of displaced ulnar collateral ligament tears of the thumb: the Stener lesion revisited
Purpose To retrospectively characterize the ultrasound appearance of displaced ulnar collateral ligament (UCL) tears that are proven at surgery, and then determine the accuracy of the resulting ultrasound criteria in differentiating displaced from non-displaced UCL tears. Materials and methods After...
Saved in:
Published in: | Skeletal radiology 2013-05, Vol.42 (5), p.667-673 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Purpose
To retrospectively characterize the ultrasound appearance of displaced ulnar collateral ligament (UCL) tears that are proven at surgery, and then determine the accuracy of the resulting ultrasound criteria in differentiating displaced from non-displaced UCL tears.
Materials and methods
After institutional review board approval, 26 patients were identified from the radiology information system over a 10-year period that had ultrasound evaluation of the thumb and surgically proven UCL tear. Retrospective review of the displaced full-thickness tears was carried out to characterize displaced tears and to establish ultrasound criteria for such tears. A repeat retrospective review 4 months later of all UCL tears applied the criteria to determine accuracy of ultrasound in the diagnosis of displaced full-thickness UCL tear.
Results
The 26 subjects consisted of 17 displaced full-thickness UCL tears, seven non-displaced full-thickness tears, and two partial-thickness tears at surgery. Retrospective ultrasound review of displaced full-thickness tears identified two criteria present in all cases: non-visualization of the UCL ligament and presence of a heterogeneous mass-like area proximal to the first metacarpophalangeal joint. Applying these criteria at the second retrospective review resulted in 100 % sensitivity, specificity, positive predictive value, negative predictive value, and accuracy.
Conclusions
The ultrasound findings of absent UCL fibers and presence of a heterogeneous mass-like abnormality proximal to the first metacarpophalangeal joint achieved 100 % accuracy in differentiating displaced from non-displaced full-thickness UCL tear of the thumb. Displaced full-thickness UCL tears most commonly were located proximal to the adductor aponeurosis. |
---|---|