Loading…
Evaluation of domain randomness in periodically poled lithium niobate by diffraction noise measurement
Random duty-cycle errors (RDE) in ferroelectric quasi-phase-matching (QPM) devices not only affect the frequency conversion efficiency, but also generate non-phase-matched parasitic noise that can be detrimental to some applications. We demonstrate an accurate but simple method for measuring the RDE...
Saved in:
Published in: | Optics express 2013-12, Vol.21 (25), p.30221-30226 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c329t-9e13cef904f4b87cb18d526cc50e44f4de42cb6305c92f7d69815d7c2ee622e13 |
---|---|
cites | cdi_FETCH-LOGICAL-c329t-9e13cef904f4b87cb18d526cc50e44f4de42cb6305c92f7d69815d7c2ee622e13 |
container_end_page | 30226 |
container_issue | 25 |
container_start_page | 30221 |
container_title | Optics express |
container_volume | 21 |
creator | Dwivedi, Prashant Povel Choi, Hee Joo Kim, Byoung Joo Cha, Myoungsik |
description | Random duty-cycle errors (RDE) in ferroelectric quasi-phase-matching (QPM) devices not only affect the frequency conversion efficiency, but also generate non-phase-matched parasitic noise that can be detrimental to some applications. We demonstrate an accurate but simple method for measuring the RDE in periodically poled lithium niobate. Due to the equivalence between the undepleted harmonic generation spectrum and the diffraction pattern from the QPM grating, we employed linear diffraction measurement which is much simpler than tunable harmonic generation experiments [J. S. Pelc, et al., Opt. Lett.36, 864-866 (2011)]. As a result, we could relate the RDE for the QPM device to the relative noise intensity between the diffraction orders. |
doi_str_mv | 10.1364/OE.21.030221 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1499149825</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1499149825</sourcerecordid><originalsourceid>FETCH-LOGICAL-c329t-9e13cef904f4b87cb18d526cc50e44f4de42cb6305c92f7d69815d7c2ee622e13</originalsourceid><addsrcrecordid>eNpNkL1PwzAQxS0EolDYmJFHBlJsx_nwiKrwIVXqAnPk2Gdh5NjBTpD63xNoQQyne-_0uzc8hK4oWdG85HfbZsXoiuSEMXqEzigRPOOkro7_6QU6T-mdEMorUZ2iBeMF5SUhZ8g0n9JNcrTB42CwDr20HkfpZ-UhJTy7AaIN2irp3A4PwYHGzo5vduqxt6GTI-Buh7U1Jkr1k-SDTYB7kGmK0IMfL9CJkS7B5WEv0etD87J-yjbbx-f1_SZTORNjJoDmCowg3PCurlRHa12wUqmCAJ9vGjhTXZmTQglmKl2Kmha6UgygZGx-XqKbfe4Qw8cEaWx7mxQ4Jz2EKbWUCzFPzYoZvd2jKoaUIph2iLaXcddS0n43226bltF23-yMXx-Sp64H_Qf_Vpl_AfRrdTM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1499149825</pqid></control><display><type>article</type><title>Evaluation of domain randomness in periodically poled lithium niobate by diffraction noise measurement</title><source>EZB Electronic Journals Library</source><creator>Dwivedi, Prashant Povel ; Choi, Hee Joo ; Kim, Byoung Joo ; Cha, Myoungsik</creator><creatorcontrib>Dwivedi, Prashant Povel ; Choi, Hee Joo ; Kim, Byoung Joo ; Cha, Myoungsik</creatorcontrib><description>Random duty-cycle errors (RDE) in ferroelectric quasi-phase-matching (QPM) devices not only affect the frequency conversion efficiency, but also generate non-phase-matched parasitic noise that can be detrimental to some applications. We demonstrate an accurate but simple method for measuring the RDE in periodically poled lithium niobate. Due to the equivalence between the undepleted harmonic generation spectrum and the diffraction pattern from the QPM grating, we employed linear diffraction measurement which is much simpler than tunable harmonic generation experiments [J. S. Pelc, et al., Opt. Lett.36, 864-866 (2011)]. As a result, we could relate the RDE for the QPM device to the relative noise intensity between the diffraction orders.</description><identifier>ISSN: 1094-4087</identifier><identifier>EISSN: 1094-4087</identifier><identifier>DOI: 10.1364/OE.21.030221</identifier><identifier>PMID: 24514600</identifier><language>eng</language><publisher>United States</publisher><ispartof>Optics express, 2013-12, Vol.21 (25), p.30221-30226</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c329t-9e13cef904f4b87cb18d526cc50e44f4de42cb6305c92f7d69815d7c2ee622e13</citedby><cites>FETCH-LOGICAL-c329t-9e13cef904f4b87cb18d526cc50e44f4de42cb6305c92f7d69815d7c2ee622e13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24514600$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Dwivedi, Prashant Povel</creatorcontrib><creatorcontrib>Choi, Hee Joo</creatorcontrib><creatorcontrib>Kim, Byoung Joo</creatorcontrib><creatorcontrib>Cha, Myoungsik</creatorcontrib><title>Evaluation of domain randomness in periodically poled lithium niobate by diffraction noise measurement</title><title>Optics express</title><addtitle>Opt Express</addtitle><description>Random duty-cycle errors (RDE) in ferroelectric quasi-phase-matching (QPM) devices not only affect the frequency conversion efficiency, but also generate non-phase-matched parasitic noise that can be detrimental to some applications. We demonstrate an accurate but simple method for measuring the RDE in periodically poled lithium niobate. Due to the equivalence between the undepleted harmonic generation spectrum and the diffraction pattern from the QPM grating, we employed linear diffraction measurement which is much simpler than tunable harmonic generation experiments [J. S. Pelc, et al., Opt. Lett.36, 864-866 (2011)]. As a result, we could relate the RDE for the QPM device to the relative noise intensity between the diffraction orders.</description><issn>1094-4087</issn><issn>1094-4087</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNpNkL1PwzAQxS0EolDYmJFHBlJsx_nwiKrwIVXqAnPk2Gdh5NjBTpD63xNoQQyne-_0uzc8hK4oWdG85HfbZsXoiuSEMXqEzigRPOOkro7_6QU6T-mdEMorUZ2iBeMF5SUhZ8g0n9JNcrTB42CwDr20HkfpZ-UhJTy7AaIN2irp3A4PwYHGzo5vduqxt6GTI-Buh7U1Jkr1k-SDTYB7kGmK0IMfL9CJkS7B5WEv0etD87J-yjbbx-f1_SZTORNjJoDmCowg3PCurlRHa12wUqmCAJ9vGjhTXZmTQglmKl2Kmha6UgygZGx-XqKbfe4Qw8cEaWx7mxQ4Jz2EKbWUCzFPzYoZvd2jKoaUIph2iLaXcddS0n43226bltF23-yMXx-Sp64H_Qf_Vpl_AfRrdTM</recordid><startdate>20131216</startdate><enddate>20131216</enddate><creator>Dwivedi, Prashant Povel</creator><creator>Choi, Hee Joo</creator><creator>Kim, Byoung Joo</creator><creator>Cha, Myoungsik</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20131216</creationdate><title>Evaluation of domain randomness in periodically poled lithium niobate by diffraction noise measurement</title><author>Dwivedi, Prashant Povel ; Choi, Hee Joo ; Kim, Byoung Joo ; Cha, Myoungsik</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c329t-9e13cef904f4b87cb18d526cc50e44f4de42cb6305c92f7d69815d7c2ee622e13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dwivedi, Prashant Povel</creatorcontrib><creatorcontrib>Choi, Hee Joo</creatorcontrib><creatorcontrib>Kim, Byoung Joo</creatorcontrib><creatorcontrib>Cha, Myoungsik</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Dwivedi, Prashant Povel</au><au>Choi, Hee Joo</au><au>Kim, Byoung Joo</au><au>Cha, Myoungsik</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of domain randomness in periodically poled lithium niobate by diffraction noise measurement</atitle><jtitle>Optics express</jtitle><addtitle>Opt Express</addtitle><date>2013-12-16</date><risdate>2013</risdate><volume>21</volume><issue>25</issue><spage>30221</spage><epage>30226</epage><pages>30221-30226</pages><issn>1094-4087</issn><eissn>1094-4087</eissn><abstract>Random duty-cycle errors (RDE) in ferroelectric quasi-phase-matching (QPM) devices not only affect the frequency conversion efficiency, but also generate non-phase-matched parasitic noise that can be detrimental to some applications. We demonstrate an accurate but simple method for measuring the RDE in periodically poled lithium niobate. Due to the equivalence between the undepleted harmonic generation spectrum and the diffraction pattern from the QPM grating, we employed linear diffraction measurement which is much simpler than tunable harmonic generation experiments [J. S. Pelc, et al., Opt. Lett.36, 864-866 (2011)]. As a result, we could relate the RDE for the QPM device to the relative noise intensity between the diffraction orders.</abstract><cop>United States</cop><pmid>24514600</pmid><doi>10.1364/OE.21.030221</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1094-4087 |
ispartof | Optics express, 2013-12, Vol.21 (25), p.30221-30226 |
issn | 1094-4087 1094-4087 |
language | eng |
recordid | cdi_proquest_miscellaneous_1499149825 |
source | EZB Electronic Journals Library |
title | Evaluation of domain randomness in periodically poled lithium niobate by diffraction noise measurement |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T10%3A45%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20domain%20randomness%20in%20periodically%20poled%20lithium%20niobate%20by%20diffraction%20noise%20measurement&rft.jtitle=Optics%20express&rft.au=Dwivedi,%20Prashant%20Povel&rft.date=2013-12-16&rft.volume=21&rft.issue=25&rft.spage=30221&rft.epage=30226&rft.pages=30221-30226&rft.issn=1094-4087&rft.eissn=1094-4087&rft_id=info:doi/10.1364/OE.21.030221&rft_dat=%3Cproquest_cross%3E1499149825%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c329t-9e13cef904f4b87cb18d526cc50e44f4de42cb6305c92f7d69815d7c2ee622e13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1499149825&rft_id=info:pmid/24514600&rfr_iscdi=true |