Loading…

Design and evaluation of a new ergonomic handle for instruments in minimally invasive surgery

Abstract Background Laparoscopic surgery techniques have been demonstrated to provide massive benefits to patients. However, surgeons are subjected to hardworking conditions because of the poor ergonomic design of the instruments. In this article, a new ergonomic handle design is presented. This han...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of surgical research 2014-05, Vol.188 (1), p.88-99
Main Authors: Sancibrian, Ramon, PhD, Gutierrez-Diez, MarĂ­a C., MD, PhD, Torre-Ferrero, Carlos, PhD, Benito-Gonzalez, Maria A., RN, Redondo-Figuero, Carlos, MD, PhD, Manuel-Palazuelos, Jose C., MD, PhD
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract Background Laparoscopic surgery techniques have been demonstrated to provide massive benefits to patients. However, surgeons are subjected to hardworking conditions because of the poor ergonomic design of the instruments. In this article, a new ergonomic handle design is presented. This handle is designed using ergonomic principles, trying to provide both more intuitive manipulation of the instrument and a shape that reduces the high-pressure zones in the contact with the surgeon's hand. Materials and methods The ergonomic characteristics of the new handle were evaluated using objective and subjective studies. The experimental evaluation was performed using 28 volunteers by means of the comparison of the new handle with the ring-handle (RH) concept in an instrument available on the market. The volunteers' muscle activation and motions of the hand, wrist, and arm were studied while they performed different tasks. The data measured in the experiment include electromyography and goniometry values. Results The results obtained from the subjective analysis reveal that most volunteers (64%) preferred the new prototype to the RH, reporting less pain and less difficulty to complete the tasks. The results from the objective study reveal that the hyperflexion of the wrist required for the manipulation of the instrument is strongly reduced. Conclusions The new ergonomic handle not only provides important ergonomic advantages but also improves the efficiency when completing the tasks. Compared with RH instruments, the new prototype reduced the high-pressure areas and the extreme motions of the wrist.
ISSN:0022-4804
1095-8673
DOI:10.1016/j.jss.2013.12.021