Loading…

Effect of flame-sprayed Ala12Si coatings on the failure behaviour of pressurized fibre-reinforced composite tubes

Internal pressurization testing at room temperature was performed to evaluate the effect of flame-spraying aluminum-12silicon on the leakage behavior of fibre-reinforced composite tubes fabricated by filament winding, and covered with garnet sand. A group of specimens were completely coated with fla...

Full description

Saved in:
Bibliographic Details
Published in:Polymer testing 2013-12, Vol.32 (8), p.1522-1528
Main Authors: Gonzalez, R, McDonald, A, Mertiny, P
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Internal pressurization testing at room temperature was performed to evaluate the effect of flame-spraying aluminum-12silicon on the leakage behavior of fibre-reinforced composite tubes fabricated by filament winding, and covered with garnet sand. A group of specimens were completely coated with flame-sprayed metal particles and another set remained uncoated. t-tests were conducted at a significance level of I- = 0.05 to analyze the effect of the coating on the leakage behavior of the specimens. Ultraviolet imaging was used to illustrate a characteristic leakage pattern of the composite tubes. Coated specimens exhibited slightly higher mean leakage and burst pressures than the uncoated specimens. The t-test results provided strong statistical evidence that the flame spraying process employed did not damage the filament wound tubes covered with garnet sand.
ISSN:0142-9418
DOI:10.1016/j.polymertesting.2013.10.002