Loading…
Reliability, agreement, and validity of digital weighing scale with MatScan in limb load measurement
Limb loading measurements serve as an objective evaluation of asymmetrical weight bearing in the lower limb. Digital weighing scales (DWSs) could be used in clinical settings for measurement of static limb loading. However, ambiguity exists whether limb loading measurements of DWSs are comparable wi...
Saved in:
Published in: | Journal of rehabilitation research and development 2014-01, Vol.51 (4), p.591-598 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c439t-3945aa4e88754bb36e541c43b43353138a37906898c002a849e858fcf62218253 |
---|---|
cites | cdi_FETCH-LOGICAL-c439t-3945aa4e88754bb36e541c43b43353138a37906898c002a849e858fcf62218253 |
container_end_page | 598 |
container_issue | 4 |
container_start_page | 591 |
container_title | Journal of rehabilitation research and development |
container_volume | 51 |
creator | Kumar, Senthil N S Omar, Baharudin Htwe, Ohnmar Joseph, Leonard H Krishnan, Jagannathan Jafarzedah Esfehani, Ali Min, Lee L |
description | Limb loading measurements serve as an objective evaluation of asymmetrical weight bearing in the lower limb. Digital weighing scales (DWSs) could be used in clinical settings for measurement of static limb loading. However, ambiguity exists whether limb loading measurements of DWSs are comparable with a standard tool such as MatScan. A cross-sectional study composed of 33 nondisabled participants was conducted to investigate the reliability, agreement, and validity of DWSs with MatScan in static standing. Amounts of weight distribution and plantar pressure on the individual lower limb were measured using two DWSs (A, B) and MatScan during eyes open (EO) and eyes closed (EC) conditions. The results showed that intra- and interrater reliability (3, 1) were excellent (0.94-0.97) within and between DWS A and B. Bland-Altman plot revealed good agreement between DWS and MatScan in EO and EC conditions. The area under the receiver operating characteristic curve was significant and identified as 0.68 (p = 0.01). The measurements obtained with DWSs are valid and in agreement with MatScan measurements. Hence, DWSs could be used interchangeably with MatScan and could provide clinicians an objective measurement of limb loading suitable for clinical settings. |
doi_str_mv | 10.1682/JRRD.2013.07.0166 |
format | article |
fullrecord | <record><control><sourceid>gale_proqu</sourceid><recordid>TN_cdi_proquest_miscellaneous_1555625204</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A383047838</galeid><sourcerecordid>A383047838</sourcerecordid><originalsourceid>FETCH-LOGICAL-c439t-3945aa4e88754bb36e541c43b43353138a37906898c002a849e858fcf62218253</originalsourceid><addsrcrecordid>eNptkUtv1TAQhS0EorcXfgAbZIkNiyZ4_IidZdXyVBHSBdaW4zipK8cpdkLVf49DCwKEvBhr5pyjGX0IPQNSQ6Poqw-Hw3lNCbCayJpA0zxAO2iZqoAJ-hDtiOSqkhLgCB3nfEUIoYzCY3REBXAOku5Qf3DBm84Hv9yeYDMm5yYXl_KNPf5ugu_LAM8D7v3oFxPwjfPjpY8jztYEh2_8cok_muWzNRH7iIOfOhxm0-PJmbymn2lP0KPBhOye3tc9-vrm9Zezd9XFp7fvz04vKstZu1Ss5cIY7pSSgncda5zgUEYdZ0wwYMow2ZJGtcqWS4zirVNCDXZoKAVFBdujl3e512n-trq86Mln60Iw0c1r1iCEaKighBfpi3-kV_OaYtluUzFQBP5UjeVW7eMwL8nYLVSfMsUIl6qUPar_oyqvd5O3c3SDL_2_DHBnsGnOOblBXyc_mXSrgeiNrN7I6o2sJlJvZIvn-f3Caze5_rfjF0r2AxeTmr4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1553180104</pqid></control><display><type>article</type><title>Reliability, agreement, and validity of digital weighing scale with MatScan in limb load measurement</title><source>Alma/SFX Local Collection</source><creator>Kumar, Senthil N S ; Omar, Baharudin ; Htwe, Ohnmar ; Joseph, Leonard H ; Krishnan, Jagannathan ; Jafarzedah Esfehani, Ali ; Min, Lee L</creator><creatorcontrib>Kumar, Senthil N S ; Omar, Baharudin ; Htwe, Ohnmar ; Joseph, Leonard H ; Krishnan, Jagannathan ; Jafarzedah Esfehani, Ali ; Min, Lee L ; MsPT ; Hons</creatorcontrib><description>Limb loading measurements serve as an objective evaluation of asymmetrical weight bearing in the lower limb. Digital weighing scales (DWSs) could be used in clinical settings for measurement of static limb loading. However, ambiguity exists whether limb loading measurements of DWSs are comparable with a standard tool such as MatScan. A cross-sectional study composed of 33 nondisabled participants was conducted to investigate the reliability, agreement, and validity of DWSs with MatScan in static standing. Amounts of weight distribution and plantar pressure on the individual lower limb were measured using two DWSs (A, B) and MatScan during eyes open (EO) and eyes closed (EC) conditions. The results showed that intra- and interrater reliability (3, 1) were excellent (0.94-0.97) within and between DWS A and B. Bland-Altman plot revealed good agreement between DWS and MatScan in EO and EC conditions. The area under the receiver operating characteristic curve was significant and identified as 0.68 (p = 0.01). The measurements obtained with DWSs are valid and in agreement with MatScan measurements. Hence, DWSs could be used interchangeably with MatScan and could provide clinicians an objective measurement of limb loading suitable for clinical settings.</description><identifier>ISSN: 0748-7711</identifier><identifier>EISSN: 1938-1352</identifier><identifier>DOI: 10.1682/JRRD.2013.07.0166</identifier><identifier>PMID: 25144172</identifier><identifier>CODEN: JRRDDB</identifier><language>eng</language><publisher>United States: Department of Veterans Affairs</publisher><subject>Activities of daily living ; Aged ; Agreements ; Analysis ; Area Under Curve ; Biofeedback ; Body weight ; Calibration ; Clinical medicine ; Cross-Sectional Studies ; Female ; Health aspects ; Humans ; Load ; Lower Extremity - physiology ; Male ; Measurement ; Middle Aged ; Posture ; Pressure distribution ; Reproducibility of Results ; ROC Curve ; Studies ; Validity ; Weight-Bearing ; Weights and Measures - instrumentation</subject><ispartof>Journal of rehabilitation research and development, 2014-01, Vol.51 (4), p.591-598</ispartof><rights>COPYRIGHT 2014 Department of Veterans Affairs</rights><rights>Copyright Superintendent of Documents 2014</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c439t-3945aa4e88754bb36e541c43b43353138a37906898c002a849e858fcf62218253</citedby><cites>FETCH-LOGICAL-c439t-3945aa4e88754bb36e541c43b43353138a37906898c002a849e858fcf62218253</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25144172$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kumar, Senthil N S</creatorcontrib><creatorcontrib>Omar, Baharudin</creatorcontrib><creatorcontrib>Htwe, Ohnmar</creatorcontrib><creatorcontrib>Joseph, Leonard H</creatorcontrib><creatorcontrib>Krishnan, Jagannathan</creatorcontrib><creatorcontrib>Jafarzedah Esfehani, Ali</creatorcontrib><creatorcontrib>Min, Lee L</creatorcontrib><creatorcontrib>MsPT</creatorcontrib><creatorcontrib>Hons</creatorcontrib><title>Reliability, agreement, and validity of digital weighing scale with MatScan in limb load measurement</title><title>Journal of rehabilitation research and development</title><addtitle>J Rehabil Res Dev</addtitle><description>Limb loading measurements serve as an objective evaluation of asymmetrical weight bearing in the lower limb. Digital weighing scales (DWSs) could be used in clinical settings for measurement of static limb loading. However, ambiguity exists whether limb loading measurements of DWSs are comparable with a standard tool such as MatScan. A cross-sectional study composed of 33 nondisabled participants was conducted to investigate the reliability, agreement, and validity of DWSs with MatScan in static standing. Amounts of weight distribution and plantar pressure on the individual lower limb were measured using two DWSs (A, B) and MatScan during eyes open (EO) and eyes closed (EC) conditions. The results showed that intra- and interrater reliability (3, 1) were excellent (0.94-0.97) within and between DWS A and B. Bland-Altman plot revealed good agreement between DWS and MatScan in EO and EC conditions. The area under the receiver operating characteristic curve was significant and identified as 0.68 (p = 0.01). The measurements obtained with DWSs are valid and in agreement with MatScan measurements. Hence, DWSs could be used interchangeably with MatScan and could provide clinicians an objective measurement of limb loading suitable for clinical settings.</description><subject>Activities of daily living</subject><subject>Aged</subject><subject>Agreements</subject><subject>Analysis</subject><subject>Area Under Curve</subject><subject>Biofeedback</subject><subject>Body weight</subject><subject>Calibration</subject><subject>Clinical medicine</subject><subject>Cross-Sectional Studies</subject><subject>Female</subject><subject>Health aspects</subject><subject>Humans</subject><subject>Load</subject><subject>Lower Extremity - physiology</subject><subject>Male</subject><subject>Measurement</subject><subject>Middle Aged</subject><subject>Posture</subject><subject>Pressure distribution</subject><subject>Reproducibility of Results</subject><subject>ROC Curve</subject><subject>Studies</subject><subject>Validity</subject><subject>Weight-Bearing</subject><subject>Weights and Measures - instrumentation</subject><issn>0748-7711</issn><issn>1938-1352</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNptkUtv1TAQhS0EorcXfgAbZIkNiyZ4_IidZdXyVBHSBdaW4zipK8cpdkLVf49DCwKEvBhr5pyjGX0IPQNSQ6Poqw-Hw3lNCbCayJpA0zxAO2iZqoAJ-hDtiOSqkhLgCB3nfEUIoYzCY3REBXAOku5Qf3DBm84Hv9yeYDMm5yYXl_KNPf5ugu_LAM8D7v3oFxPwjfPjpY8jztYEh2_8cok_muWzNRH7iIOfOhxm0-PJmbymn2lP0KPBhOye3tc9-vrm9Zezd9XFp7fvz04vKstZu1Ss5cIY7pSSgncda5zgUEYdZ0wwYMow2ZJGtcqWS4zirVNCDXZoKAVFBdujl3e512n-trq86Mln60Iw0c1r1iCEaKighBfpi3-kV_OaYtluUzFQBP5UjeVW7eMwL8nYLVSfMsUIl6qUPar_oyqvd5O3c3SDL_2_DHBnsGnOOblBXyc_mXSrgeiNrN7I6o2sJlJvZIvn-f3Caze5_rfjF0r2AxeTmr4</recordid><startdate>20140101</startdate><enddate>20140101</enddate><creator>Kumar, Senthil N S</creator><creator>Omar, Baharudin</creator><creator>Htwe, Ohnmar</creator><creator>Joseph, Leonard H</creator><creator>Krishnan, Jagannathan</creator><creator>Jafarzedah Esfehani, Ali</creator><creator>Min, Lee L</creator><general>Department of Veterans Affairs</general><general>Superintendent of Documents</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>4T-</scope><scope>7QO</scope><scope>7RV</scope><scope>7TK</scope><scope>7TS</scope><scope>7X7</scope><scope>7XB</scope><scope>88C</scope><scope>88E</scope><scope>88I</scope><scope>8AF</scope><scope>8AO</scope><scope>8FD</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>8G5</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FR3</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>KB0</scope><scope>M0S</scope><scope>M0T</scope><scope>M1P</scope><scope>M2O</scope><scope>M2P</scope><scope>MBDVC</scope><scope>NAPCQ</scope><scope>P64</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>S0X</scope><scope>7X8</scope></search><sort><creationdate>20140101</creationdate><title>Reliability, agreement, and validity of digital weighing scale with MatScan in limb load measurement</title><author>Kumar, Senthil N S ; Omar, Baharudin ; Htwe, Ohnmar ; Joseph, Leonard H ; Krishnan, Jagannathan ; Jafarzedah Esfehani, Ali ; Min, Lee L</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c439t-3945aa4e88754bb36e541c43b43353138a37906898c002a849e858fcf62218253</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Activities of daily living</topic><topic>Aged</topic><topic>Agreements</topic><topic>Analysis</topic><topic>Area Under Curve</topic><topic>Biofeedback</topic><topic>Body weight</topic><topic>Calibration</topic><topic>Clinical medicine</topic><topic>Cross-Sectional Studies</topic><topic>Female</topic><topic>Health aspects</topic><topic>Humans</topic><topic>Load</topic><topic>Lower Extremity - physiology</topic><topic>Male</topic><topic>Measurement</topic><topic>Middle Aged</topic><topic>Posture</topic><topic>Pressure distribution</topic><topic>Reproducibility of Results</topic><topic>ROC Curve</topic><topic>Studies</topic><topic>Validity</topic><topic>Weight-Bearing</topic><topic>Weights and Measures - instrumentation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kumar, Senthil N S</creatorcontrib><creatorcontrib>Omar, Baharudin</creatorcontrib><creatorcontrib>Htwe, Ohnmar</creatorcontrib><creatorcontrib>Joseph, Leonard H</creatorcontrib><creatorcontrib>Krishnan, Jagannathan</creatorcontrib><creatorcontrib>Jafarzedah Esfehani, Ali</creatorcontrib><creatorcontrib>Min, Lee L</creatorcontrib><creatorcontrib>MsPT</creatorcontrib><creatorcontrib>Hons</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Docstoc</collection><collection>Biotechnology Research Abstracts</collection><collection>Nursing & Allied Health Database</collection><collection>Neurosciences Abstracts</collection><collection>Physical Education Index</collection><collection>ProQuest Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Healthcare Administration Database (Alumni)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Science Database (Alumni Edition)</collection><collection>STEM Database</collection><collection>ProQuest Pharma Collection</collection><collection>Technology Research Database</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Research Library (Alumni Edition)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>eLibrary</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Engineering Research Database</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep (ProQuest)</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Nursing & Allied Health Database (Alumni Edition)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>ProQuest Healthcare Administration Database</collection><collection>PML(ProQuest Medical Library)</collection><collection>ProQuest Research Library</collection><collection>Science Database (ProQuest)</collection><collection>Research Library (Corporate)</collection><collection>Nursing & Allied Health Premium</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>SIRS Editorial</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of rehabilitation research and development</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kumar, Senthil N S</au><au>Omar, Baharudin</au><au>Htwe, Ohnmar</au><au>Joseph, Leonard H</au><au>Krishnan, Jagannathan</au><au>Jafarzedah Esfehani, Ali</au><au>Min, Lee L</au><aucorp>MsPT</aucorp><aucorp>Hons</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reliability, agreement, and validity of digital weighing scale with MatScan in limb load measurement</atitle><jtitle>Journal of rehabilitation research and development</jtitle><addtitle>J Rehabil Res Dev</addtitle><date>2014-01-01</date><risdate>2014</risdate><volume>51</volume><issue>4</issue><spage>591</spage><epage>598</epage><pages>591-598</pages><issn>0748-7711</issn><eissn>1938-1352</eissn><coden>JRRDDB</coden><abstract>Limb loading measurements serve as an objective evaluation of asymmetrical weight bearing in the lower limb. Digital weighing scales (DWSs) could be used in clinical settings for measurement of static limb loading. However, ambiguity exists whether limb loading measurements of DWSs are comparable with a standard tool such as MatScan. A cross-sectional study composed of 33 nondisabled participants was conducted to investigate the reliability, agreement, and validity of DWSs with MatScan in static standing. Amounts of weight distribution and plantar pressure on the individual lower limb were measured using two DWSs (A, B) and MatScan during eyes open (EO) and eyes closed (EC) conditions. The results showed that intra- and interrater reliability (3, 1) were excellent (0.94-0.97) within and between DWS A and B. Bland-Altman plot revealed good agreement between DWS and MatScan in EO and EC conditions. The area under the receiver operating characteristic curve was significant and identified as 0.68 (p = 0.01). The measurements obtained with DWSs are valid and in agreement with MatScan measurements. Hence, DWSs could be used interchangeably with MatScan and could provide clinicians an objective measurement of limb loading suitable for clinical settings.</abstract><cop>United States</cop><pub>Department of Veterans Affairs</pub><pmid>25144172</pmid><doi>10.1682/JRRD.2013.07.0166</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0748-7711 |
ispartof | Journal of rehabilitation research and development, 2014-01, Vol.51 (4), p.591-598 |
issn | 0748-7711 1938-1352 |
language | eng |
recordid | cdi_proquest_miscellaneous_1555625204 |
source | Alma/SFX Local Collection |
subjects | Activities of daily living Aged Agreements Analysis Area Under Curve Biofeedback Body weight Calibration Clinical medicine Cross-Sectional Studies Female Health aspects Humans Load Lower Extremity - physiology Male Measurement Middle Aged Posture Pressure distribution Reproducibility of Results ROC Curve Studies Validity Weight-Bearing Weights and Measures - instrumentation |
title | Reliability, agreement, and validity of digital weighing scale with MatScan in limb load measurement |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T19%3A20%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reliability,%20agreement,%20and%20validity%20of%20digital%20weighing%20scale%20with%20MatScan%20in%20limb%20load%20measurement&rft.jtitle=Journal%20of%20rehabilitation%20research%20and%20development&rft.au=Kumar,%20Senthil%20N%20S&rft.aucorp=MsPT&rft.date=2014-01-01&rft.volume=51&rft.issue=4&rft.spage=591&rft.epage=598&rft.pages=591-598&rft.issn=0748-7711&rft.eissn=1938-1352&rft.coden=JRRDDB&rft_id=info:doi/10.1682/JRRD.2013.07.0166&rft_dat=%3Cgale_proqu%3EA383047838%3C/gale_proqu%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c439t-3945aa4e88754bb36e541c43b43353138a37906898c002a849e858fcf62218253%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1553180104&rft_id=info:pmid/25144172&rft_galeid=A383047838&rfr_iscdi=true |