Reliability, agreement, and validity of digital weighing scale with MatScan in limb load measurement

Limb loading measurements serve as an objective evaluation of asymmetrical weight bearing in the lower limb. Digital weighing scales (DWSs) could be used in clinical settings for measurement of static limb loading. However, ambiguity exists whether limb loading measurements of DWSs are comparable wi...

Full description

Saved in:
Bibliographic Details
Published in:Journal of rehabilitation research and development 2014-01, Vol.51 (4), p.591-598
Main Authors: Kumar, Senthil N S, Omar, Baharudin, Htwe, Ohnmar, Joseph, Leonard H, Krishnan, Jagannathan, Jafarzedah Esfehani, Ali, Min, Lee L
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c439t-3945aa4e88754bb36e541c43b43353138a37906898c002a849e858fcf62218253
cites cdi_FETCH-LOGICAL-c439t-3945aa4e88754bb36e541c43b43353138a37906898c002a849e858fcf62218253
container_end_page 598
container_issue 4
container_start_page 591
container_title Journal of rehabilitation research and development
container_volume 51
creator Kumar, Senthil N S
Omar, Baharudin
Htwe, Ohnmar
Joseph, Leonard H
Krishnan, Jagannathan
Jafarzedah Esfehani, Ali
Min, Lee L
description Limb loading measurements serve as an objective evaluation of asymmetrical weight bearing in the lower limb. Digital weighing scales (DWSs) could be used in clinical settings for measurement of static limb loading. However, ambiguity exists whether limb loading measurements of DWSs are comparable with a standard tool such as MatScan. A cross-sectional study composed of 33 nondisabled participants was conducted to investigate the reliability, agreement, and validity of DWSs with MatScan in static standing. Amounts of weight distribution and plantar pressure on the individual lower limb were measured using two DWSs (A, B) and MatScan during eyes open (EO) and eyes closed (EC) conditions. The results showed that intra- and interrater reliability (3, 1) were excellent (0.94-0.97) within and between DWS A and B. Bland-Altman plot revealed good agreement between DWS and MatScan in EO and EC conditions. The area under the receiver operating characteristic curve was significant and identified as 0.68 (p = 0.01). The measurements obtained with DWSs are valid and in agreement with MatScan measurements. Hence, DWSs could be used interchangeably with MatScan and could provide clinicians an objective measurement of limb loading suitable for clinical settings.
doi_str_mv 10.1682/JRRD.2013.07.0166
format article
fullrecord <record><control><sourceid>gale_proqu</sourceid><recordid>TN_cdi_proquest_miscellaneous_1555625204</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A383047838</galeid><sourcerecordid>A383047838</sourcerecordid><originalsourceid>FETCH-LOGICAL-c439t-3945aa4e88754bb36e541c43b43353138a37906898c002a849e858fcf62218253</originalsourceid><addsrcrecordid>eNptkUtv1TAQhS0EorcXfgAbZIkNiyZ4_IidZdXyVBHSBdaW4zipK8cpdkLVf49DCwKEvBhr5pyjGX0IPQNSQ6Poqw-Hw3lNCbCayJpA0zxAO2iZqoAJ-hDtiOSqkhLgCB3nfEUIoYzCY3REBXAOku5Qf3DBm84Hv9yeYDMm5yYXl_KNPf5ugu_LAM8D7v3oFxPwjfPjpY8jztYEh2_8cok_muWzNRH7iIOfOhxm0-PJmbymn2lP0KPBhOye3tc9-vrm9Zezd9XFp7fvz04vKstZu1Ss5cIY7pSSgncda5zgUEYdZ0wwYMow2ZJGtcqWS4zirVNCDXZoKAVFBdujl3e512n-trq86Mln60Iw0c1r1iCEaKighBfpi3-kV_OaYtluUzFQBP5UjeVW7eMwL8nYLVSfMsUIl6qUPar_oyqvd5O3c3SDL_2_DHBnsGnOOblBXyc_mXSrgeiNrN7I6o2sJlJvZIvn-f3Caze5_rfjF0r2AxeTmr4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1553180104</pqid></control><display><type>article</type><title>Reliability, agreement, and validity of digital weighing scale with MatScan in limb load measurement</title><source>Alma/SFX Local Collection</source><creator>Kumar, Senthil N S ; Omar, Baharudin ; Htwe, Ohnmar ; Joseph, Leonard H ; Krishnan, Jagannathan ; Jafarzedah Esfehani, Ali ; Min, Lee L</creator><creatorcontrib>Kumar, Senthil N S ; Omar, Baharudin ; Htwe, Ohnmar ; Joseph, Leonard H ; Krishnan, Jagannathan ; Jafarzedah Esfehani, Ali ; Min, Lee L ; MsPT ; Hons</creatorcontrib><description>Limb loading measurements serve as an objective evaluation of asymmetrical weight bearing in the lower limb. Digital weighing scales (DWSs) could be used in clinical settings for measurement of static limb loading. However, ambiguity exists whether limb loading measurements of DWSs are comparable with a standard tool such as MatScan. A cross-sectional study composed of 33 nondisabled participants was conducted to investigate the reliability, agreement, and validity of DWSs with MatScan in static standing. Amounts of weight distribution and plantar pressure on the individual lower limb were measured using two DWSs (A, B) and MatScan during eyes open (EO) and eyes closed (EC) conditions. The results showed that intra- and interrater reliability (3, 1) were excellent (0.94-0.97) within and between DWS A and B. Bland-Altman plot revealed good agreement between DWS and MatScan in EO and EC conditions. The area under the receiver operating characteristic curve was significant and identified as 0.68 (p = 0.01). The measurements obtained with DWSs are valid and in agreement with MatScan measurements. Hence, DWSs could be used interchangeably with MatScan and could provide clinicians an objective measurement of limb loading suitable for clinical settings.</description><identifier>ISSN: 0748-7711</identifier><identifier>EISSN: 1938-1352</identifier><identifier>DOI: 10.1682/JRRD.2013.07.0166</identifier><identifier>PMID: 25144172</identifier><identifier>CODEN: JRRDDB</identifier><language>eng</language><publisher>United States: Department of Veterans Affairs</publisher><subject>Activities of daily living ; Aged ; Agreements ; Analysis ; Area Under Curve ; Biofeedback ; Body weight ; Calibration ; Clinical medicine ; Cross-Sectional Studies ; Female ; Health aspects ; Humans ; Load ; Lower Extremity - physiology ; Male ; Measurement ; Middle Aged ; Posture ; Pressure distribution ; Reproducibility of Results ; ROC Curve ; Studies ; Validity ; Weight-Bearing ; Weights and Measures - instrumentation</subject><ispartof>Journal of rehabilitation research and development, 2014-01, Vol.51 (4), p.591-598</ispartof><rights>COPYRIGHT 2014 Department of Veterans Affairs</rights><rights>Copyright Superintendent of Documents 2014</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c439t-3945aa4e88754bb36e541c43b43353138a37906898c002a849e858fcf62218253</citedby><cites>FETCH-LOGICAL-c439t-3945aa4e88754bb36e541c43b43353138a37906898c002a849e858fcf62218253</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25144172$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kumar, Senthil N S</creatorcontrib><creatorcontrib>Omar, Baharudin</creatorcontrib><creatorcontrib>Htwe, Ohnmar</creatorcontrib><creatorcontrib>Joseph, Leonard H</creatorcontrib><creatorcontrib>Krishnan, Jagannathan</creatorcontrib><creatorcontrib>Jafarzedah Esfehani, Ali</creatorcontrib><creatorcontrib>Min, Lee L</creatorcontrib><creatorcontrib>MsPT</creatorcontrib><creatorcontrib>Hons</creatorcontrib><title>Reliability, agreement, and validity of digital weighing scale with MatScan in limb load measurement</title><title>Journal of rehabilitation research and development</title><addtitle>J Rehabil Res Dev</addtitle><description>Limb loading measurements serve as an objective evaluation of asymmetrical weight bearing in the lower limb. Digital weighing scales (DWSs) could be used in clinical settings for measurement of static limb loading. However, ambiguity exists whether limb loading measurements of DWSs are comparable with a standard tool such as MatScan. A cross-sectional study composed of 33 nondisabled participants was conducted to investigate the reliability, agreement, and validity of DWSs with MatScan in static standing. Amounts of weight distribution and plantar pressure on the individual lower limb were measured using two DWSs (A, B) and MatScan during eyes open (EO) and eyes closed (EC) conditions. The results showed that intra- and interrater reliability (3, 1) were excellent (0.94-0.97) within and between DWS A and B. Bland-Altman plot revealed good agreement between DWS and MatScan in EO and EC conditions. The area under the receiver operating characteristic curve was significant and identified as 0.68 (p = 0.01). The measurements obtained with DWSs are valid and in agreement with MatScan measurements. Hence, DWSs could be used interchangeably with MatScan and could provide clinicians an objective measurement of limb loading suitable for clinical settings.</description><subject>Activities of daily living</subject><subject>Aged</subject><subject>Agreements</subject><subject>Analysis</subject><subject>Area Under Curve</subject><subject>Biofeedback</subject><subject>Body weight</subject><subject>Calibration</subject><subject>Clinical medicine</subject><subject>Cross-Sectional Studies</subject><subject>Female</subject><subject>Health aspects</subject><subject>Humans</subject><subject>Load</subject><subject>Lower Extremity - physiology</subject><subject>Male</subject><subject>Measurement</subject><subject>Middle Aged</subject><subject>Posture</subject><subject>Pressure distribution</subject><subject>Reproducibility of Results</subject><subject>ROC Curve</subject><subject>Studies</subject><subject>Validity</subject><subject>Weight-Bearing</subject><subject>Weights and Measures - instrumentation</subject><issn>0748-7711</issn><issn>1938-1352</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNptkUtv1TAQhS0EorcXfgAbZIkNiyZ4_IidZdXyVBHSBdaW4zipK8cpdkLVf49DCwKEvBhr5pyjGX0IPQNSQ6Poqw-Hw3lNCbCayJpA0zxAO2iZqoAJ-hDtiOSqkhLgCB3nfEUIoYzCY3REBXAOku5Qf3DBm84Hv9yeYDMm5yYXl_KNPf5ugu_LAM8D7v3oFxPwjfPjpY8jztYEh2_8cok_muWzNRH7iIOfOhxm0-PJmbymn2lP0KPBhOye3tc9-vrm9Zezd9XFp7fvz04vKstZu1Ss5cIY7pSSgncda5zgUEYdZ0wwYMow2ZJGtcqWS4zirVNCDXZoKAVFBdujl3e512n-trq86Mln60Iw0c1r1iCEaKighBfpi3-kV_OaYtluUzFQBP5UjeVW7eMwL8nYLVSfMsUIl6qUPar_oyqvd5O3c3SDL_2_DHBnsGnOOblBXyc_mXSrgeiNrN7I6o2sJlJvZIvn-f3Caze5_rfjF0r2AxeTmr4</recordid><startdate>20140101</startdate><enddate>20140101</enddate><creator>Kumar, Senthil N S</creator><creator>Omar, Baharudin</creator><creator>Htwe, Ohnmar</creator><creator>Joseph, Leonard H</creator><creator>Krishnan, Jagannathan</creator><creator>Jafarzedah Esfehani, Ali</creator><creator>Min, Lee L</creator><general>Department of Veterans Affairs</general><general>Superintendent of Documents</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>4T-</scope><scope>7QO</scope><scope>7RV</scope><scope>7TK</scope><scope>7TS</scope><scope>7X7</scope><scope>7XB</scope><scope>88C</scope><scope>88E</scope><scope>88I</scope><scope>8AF</scope><scope>8AO</scope><scope>8FD</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>8G5</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FR3</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>KB0</scope><scope>M0S</scope><scope>M0T</scope><scope>M1P</scope><scope>M2O</scope><scope>M2P</scope><scope>MBDVC</scope><scope>NAPCQ</scope><scope>P64</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>S0X</scope><scope>7X8</scope></search><sort><creationdate>20140101</creationdate><title>Reliability, agreement, and validity of digital weighing scale with MatScan in limb load measurement</title><author>Kumar, Senthil N S ; Omar, Baharudin ; Htwe, Ohnmar ; Joseph, Leonard H ; Krishnan, Jagannathan ; Jafarzedah Esfehani, Ali ; Min, Lee L</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c439t-3945aa4e88754bb36e541c43b43353138a37906898c002a849e858fcf62218253</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Activities of daily living</topic><topic>Aged</topic><topic>Agreements</topic><topic>Analysis</topic><topic>Area Under Curve</topic><topic>Biofeedback</topic><topic>Body weight</topic><topic>Calibration</topic><topic>Clinical medicine</topic><topic>Cross-Sectional Studies</topic><topic>Female</topic><topic>Health aspects</topic><topic>Humans</topic><topic>Load</topic><topic>Lower Extremity - physiology</topic><topic>Male</topic><topic>Measurement</topic><topic>Middle Aged</topic><topic>Posture</topic><topic>Pressure distribution</topic><topic>Reproducibility of Results</topic><topic>ROC Curve</topic><topic>Studies</topic><topic>Validity</topic><topic>Weight-Bearing</topic><topic>Weights and Measures - instrumentation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kumar, Senthil N S</creatorcontrib><creatorcontrib>Omar, Baharudin</creatorcontrib><creatorcontrib>Htwe, Ohnmar</creatorcontrib><creatorcontrib>Joseph, Leonard H</creatorcontrib><creatorcontrib>Krishnan, Jagannathan</creatorcontrib><creatorcontrib>Jafarzedah Esfehani, Ali</creatorcontrib><creatorcontrib>Min, Lee L</creatorcontrib><creatorcontrib>MsPT</creatorcontrib><creatorcontrib>Hons</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Docstoc</collection><collection>Biotechnology Research Abstracts</collection><collection>Nursing &amp; Allied Health Database</collection><collection>Neurosciences Abstracts</collection><collection>Physical Education Index</collection><collection>ProQuest Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Healthcare Administration Database (Alumni)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Science Database (Alumni Edition)</collection><collection>STEM Database</collection><collection>ProQuest Pharma Collection</collection><collection>Technology Research Database</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Research Library (Alumni Edition)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>eLibrary</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Engineering Research Database</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep (ProQuest)</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Database (Alumni Edition)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>ProQuest Healthcare Administration Database</collection><collection>PML(ProQuest Medical Library)</collection><collection>ProQuest Research Library</collection><collection>Science Database (ProQuest)</collection><collection>Research Library (Corporate)</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>SIRS Editorial</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of rehabilitation research and development</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kumar, Senthil N S</au><au>Omar, Baharudin</au><au>Htwe, Ohnmar</au><au>Joseph, Leonard H</au><au>Krishnan, Jagannathan</au><au>Jafarzedah Esfehani, Ali</au><au>Min, Lee L</au><aucorp>MsPT</aucorp><aucorp>Hons</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reliability, agreement, and validity of digital weighing scale with MatScan in limb load measurement</atitle><jtitle>Journal of rehabilitation research and development</jtitle><addtitle>J Rehabil Res Dev</addtitle><date>2014-01-01</date><risdate>2014</risdate><volume>51</volume><issue>4</issue><spage>591</spage><epage>598</epage><pages>591-598</pages><issn>0748-7711</issn><eissn>1938-1352</eissn><coden>JRRDDB</coden><abstract>Limb loading measurements serve as an objective evaluation of asymmetrical weight bearing in the lower limb. Digital weighing scales (DWSs) could be used in clinical settings for measurement of static limb loading. However, ambiguity exists whether limb loading measurements of DWSs are comparable with a standard tool such as MatScan. A cross-sectional study composed of 33 nondisabled participants was conducted to investigate the reliability, agreement, and validity of DWSs with MatScan in static standing. Amounts of weight distribution and plantar pressure on the individual lower limb were measured using two DWSs (A, B) and MatScan during eyes open (EO) and eyes closed (EC) conditions. The results showed that intra- and interrater reliability (3, 1) were excellent (0.94-0.97) within and between DWS A and B. Bland-Altman plot revealed good agreement between DWS and MatScan in EO and EC conditions. The area under the receiver operating characteristic curve was significant and identified as 0.68 (p = 0.01). The measurements obtained with DWSs are valid and in agreement with MatScan measurements. Hence, DWSs could be used interchangeably with MatScan and could provide clinicians an objective measurement of limb loading suitable for clinical settings.</abstract><cop>United States</cop><pub>Department of Veterans Affairs</pub><pmid>25144172</pmid><doi>10.1682/JRRD.2013.07.0166</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0748-7711
ispartof Journal of rehabilitation research and development, 2014-01, Vol.51 (4), p.591-598
issn 0748-7711
1938-1352
language eng
recordid cdi_proquest_miscellaneous_1555625204
source Alma/SFX Local Collection
subjects Activities of daily living
Aged
Agreements
Analysis
Area Under Curve
Biofeedback
Body weight
Calibration
Clinical medicine
Cross-Sectional Studies
Female
Health aspects
Humans
Load
Lower Extremity - physiology
Male
Measurement
Middle Aged
Posture
Pressure distribution
Reproducibility of Results
ROC Curve
Studies
Validity
Weight-Bearing
Weights and Measures - instrumentation
title Reliability, agreement, and validity of digital weighing scale with MatScan in limb load measurement
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T19%3A20%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reliability,%20agreement,%20and%20validity%20of%20digital%20weighing%20scale%20with%20MatScan%20in%20limb%20load%20measurement&rft.jtitle=Journal%20of%20rehabilitation%20research%20and%20development&rft.au=Kumar,%20Senthil%20N%20S&rft.aucorp=MsPT&rft.date=2014-01-01&rft.volume=51&rft.issue=4&rft.spage=591&rft.epage=598&rft.pages=591-598&rft.issn=0748-7711&rft.eissn=1938-1352&rft.coden=JRRDDB&rft_id=info:doi/10.1682/JRRD.2013.07.0166&rft_dat=%3Cgale_proqu%3EA383047838%3C/gale_proqu%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c439t-3945aa4e88754bb36e541c43b43353138a37906898c002a849e858fcf62218253%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1553180104&rft_id=info:pmid/25144172&rft_galeid=A383047838&rfr_iscdi=true