Loading…

GeneSearch™ BLN Assay could replace frozen section and touch imprint cytology for intra-operative assessment of breast sentinel lymph nodes

Background Breast cancer sentinel lymph node (SLN) biopsy has become a common procedure. The GeneSearch™ Breast Lymph Node Assay is a real-time reverse-transcriptase polymerase chain reaction assay for detecting nodal metastases larger than 0.2 mm. The trial is a prospective multi-center clinical tr...

Full description

Saved in:
Bibliographic Details
Published in:Breast cancer (Tokyo, Japan) Japan), 2014-09, Vol.21 (5), p.583-589
Main Authors: Wang, Yong-sheng, Liu, Yan-hui, Ou-yang, Tao, Yang, Xin-hua, Wu, Jiong, Su, Feng-xi, Sun, Xiao, Zhong, Wei-xia, Liao, Ning, Yang, Wen-tao
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background Breast cancer sentinel lymph node (SLN) biopsy has become a common procedure. The GeneSearch™ Breast Lymph Node Assay is a real-time reverse-transcriptase polymerase chain reaction assay for detecting nodal metastases larger than 0.2 mm. The trial is a prospective multi-center clinical trial conducted to validate the assay in China. Methods Four hundred and seventy-nine consecutive prospective patients were enrolled from six centers. SLNs were sectioned along the short axis into multiple blocks. Odd blocks were tested by the assay intra-operatively, and even blocks were assessed by post-operative histology. Six 4- to 6-μm-thick sections were taken every 150 μm per block. In addition, intra-operative histological assessments were performed on the even blocks of 214 patients by frozen section (FS) and all blocks of 156 patients by touch imprint cytology (TIC). Results A total of 1046 SLNs were excised. Overall performance of the assay compared to post-operative histology was accuracy of 91.4 %, sensitivity of 87.5 %, and specificity of 92.9 %. There were no significant differences in assay performance of each center. After a learning curve of about 10 cases, the assay could be performed in a median time of about 35 min. The sensitivity of the assay was similar to the FS (84.9 %, P  = 0.885) and was significantly higher than the TIC (70.0 %, P  = 0.007) while the specificity of all were comparable. Conclusion The GeneSearch™ Breast Lymph Node Assay is an accurate and rapid intra-operative assay for breast SLNs and it can replace FS and TIC for application.
ISSN:1340-6868
1880-4233
DOI:10.1007/s12282-012-0437-z