Scaling analysis of PMR200 reactor cavity cooling system

The reactor cavity cooling system (RCCS) of the PMR200, a demonstration plant of very high temperature reator (VHTR), removes the residual heat, which amounts to 0.3–0.6% of the reactor full power, at both high and low pressure modes, by means of radiation and natural convection. Its operation has t...

Full description

Saved in:
Bibliographic Details
Published in:Nuclear engineering and design 2014-05, Vol.271, p.523-529
Main Authors: Bae, Yoon-Yeong, Hong, Sung-Deok, Kim, Yong-Wan
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The reactor cavity cooling system (RCCS) of the PMR200, a demonstration plant of very high temperature reator (VHTR), removes the residual heat, which amounts to 0.3–0.6% of the reactor full power, at both high and low pressure modes, by means of radiation and natural convection. Its operation has to be passive to eliminate any accidents associated with human errors. Prior to the experimental performance verification of the RCCS, a scaling analysis has been performed. In the present study, the scaling was based on the cavity radiation number. Based on it, the scaling laws between the model and prototype were derived, and applied to the RCCS down-scaling.
ISSN:0029-5493
1872-759X
DOI:10.1016/j.nucengdes.2013.12.027