Loading…

Simplified magnetic anchor-guided endoscopic submucosal dissection in dogs (with videos)

Background Magnetic anchor-guided endoscopic submucosal dissection (MAG-ESD) was developed to reduce adverse events such as bleeding and perforation and to facilitate ESD. However, the external electromagnet required miniaturization to make it suitable for daily clinical practice. Objective To evalu...

Full description

Saved in:
Bibliographic Details
Published in:Gastrointestinal endoscopy 2014-10, Vol.80 (4), p.712-716
Main Authors: Matsuzaki, Ippei, MD, Miyahara, Ryoji, MD, PhD, Hirooka, Yoshiki, MD, PhD, Funasaka, Kohei, MD, PhD, Furukawa, Kazuhiro, MD, PhD, Ohno, Eizaburo, MD, PhD, Nakamura, Masanao, MD, PhD, Kawashima, Hiroki, MD, PhD, Maeda, Osamu, MD, PhD, Watanabe, Osamu, MD, PhD, Ando, Takafumi, MD, PhD, Kobayashi, Makoto, MD, PhD, Goto, Hidemi, MD, PhD
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background Magnetic anchor-guided endoscopic submucosal dissection (MAG-ESD) was developed to reduce adverse events such as bleeding and perforation and to facilitate ESD. However, the external electromagnet required miniaturization to make it suitable for daily clinical practice. Objective To evaluate the feasibility of simplified MAG-ESD using permanent magnets. Design Case series. Setting Nagoya University Hospital. Subjects Beagle dogs. Interventions The simplified MAG-ESD was performed on 10 representative areas of the stomachs of beagle dogs. The magnetic anchor consisted of an internal magnet attached to a hemoclip. The external and internal magnets were made from the rare earth neodymium. Main Outcome Measurements The feasibility of countertraction with good visualization using simplified MAG-ESD. The rate of perforation, the time required for preparation, and attaching the magnetic anchor were also evaluated. Results All lesions were successfully resected without perforation. The magnetic anchor could be controlled easily, and direct visualization was maintained by adequate counter traction. Preparing the magnetic anchor and grasping the mucosal edge using the hemoclip was easy and required a median of only 4 minutes (range, 2-7 minutes). Limitations Animal experiment, low number and lesion size. Conclusions This simplified MAG-ESD is feasible and allowed excellent visualization in the dog stomach. The feasibility of this system should be assessed in humans.
ISSN:0016-5107
1097-6779
DOI:10.1016/j.gie.2014.05.334