Fabrication and installation of equilibrium field coils for the JT-60SA
Recently, fabrication of the first superconducting coil in JT-60SA tokamak (EF4 coil) was finished. EF4 coil has ten double pancake (DP) coils. All DP coils were stacked up to form the winding pack. In order to check the manufacturing error of DP coils, their circularities (in-plane ellipticities) w...
Saved in:
Published in: | Fusion engineering and design 2013-10, Vol.88 (6-8), p.551-554 |
---|---|
Main Authors: | , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Recently, fabrication of the first superconducting coil in JT-60SA tokamak (EF4 coil) was finished. EF4 coil has ten double pancake (DP) coils. All DP coils were stacked up to form the winding pack. In order to check the manufacturing error of DP coils, their circularities (in-plane ellipticities) were evaluated for all DP coils. Positions of conductors for each DP coil were measured before curing process. Error bars of the current centers, which were used for the index for DP coil's circularity, ranged between 1.1 and 2.5mm. During stacking the DP coils, the positions of these coils were optimized in order to cancel the error of circulation of the winding pack. As the result, the manufacturing error of the radial current center was achieved 0.6mm for the winding pack. This value was an order of magnitude smaller than the required manufacturing error of EF4 coil. |
---|---|
ISSN: | 0920-3796 1873-7196 |
DOI: | 10.1016/j.fusengdes.2013.02.096 |