Study by X-Ray Methods of the Effect of Temperature on Crystal Lattice Interplanar Distances of Pervoural’sk Quartzite Used for Induction Furnace Lining
The effect of temperature on the change in quartzite crystal lattice interplanar distances of industrial purity (IChT) used in lining induction and crucible furnaces is studied by x-ray-phase analysis (XPA). A regularity is revealed for changes in interplanar distance. A curve is plotted for these c...
Saved in:
Published in: | Refractories and industrial ceramics 2014, Vol.54 (5), p.413-415 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The effect of temperature on the change in quartzite crystal lattice interplanar distances of industrial purity (IChT) used in lining induction and crucible furnaces is studied by x-ray-phase analysis (XPA). A regularity is revealed for changes in interplanar distance. A curve is plotted for these changes. The connection of changes in crystal lattice with material properties is determined, affecting induction furnace lining life. |
---|---|
ISSN: | 1083-4877 1573-9139 |
DOI: | 10.1007/s11148-014-9622-2 |