Palladium Particles-Impregnated Natural Phosphate Electrodes for Electrochemical Determination of Mercury in Ambient Water Samples

We present here a simple procedure for the determination of mercury(II) using differential pulse anodic stripping voltammetry (DPASV) at palladium particles‐impregnated natural phosphate modified carbon paste electrodes (Pd‐NP‐CPE). The surface of modified electrode was characterized using SEM, infr...

Full description

Saved in:
Bibliographic Details
Published in:Electroanalysis (New York, N.Y.) N.Y.), 2014-08, Vol.26 (8), p.1751-1760
Main Authors: El Aroui, F., Lahrich, S., Farahi, A., Achak, M., El Gaini, L., Bakasse, M., Bouzidi, A., El Mhammedi, M. A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We present here a simple procedure for the determination of mercury(II) using differential pulse anodic stripping voltammetry (DPASV) at palladium particles‐impregnated natural phosphate modified carbon paste electrodes (Pd‐NP‐CPE). The surface of modified electrode was characterized using SEM, infrared spectroscopy, X‐ray diffraction and electrochemical analysis. All experimental variables involved in the voltammetric stripping method were optimized. The detection limit was found to be 4.99×10−8 mol L−1 (S/N=3) that is not different to the permitted value for Hg(II) in water reported by the Environmental Protection Agency (EPA). The proposed electrode exhibits good applicability for monitoring Hg(II) in tap and wastewater.
ISSN:1040-0397