Loading…
Straw chambers operating in vacuum for particle tracking and transition radiation detection in accelerator and space experiments
We have designed and tested some straw tubes prototype detectors to investigate the possibility to operate a full size chamber with extremely reduced gas leaks in a high vacuum environment in accelerator experiments or in sealed mode for astroparticle physics researches in outer space. After complet...
Saved in:
Published in: | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 1996-10, Vol.381 (1), p.39-48 |
---|---|
Main Authors: | , , , , , , , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | We have designed and tested some straw tubes prototype detectors to investigate the possibility to operate a full size chamber with extremely reduced gas leaks in a high vacuum environment in accelerator experiments or in sealed mode for astroparticle physics researches in outer space. After completing the tests we have finally built a tracking detector of 1300 channels which has run in a vacuum chamber in the experiment E864 at BNL with a leak of 7 × 10
−3Torr l/s compatible with the permeability of the materials used. |
---|---|
ISSN: | 0168-9002 1872-9576 |
DOI: | 10.1016/0168-9002(96)00674-2 |