Validity of a clinical decision rule-based alert system for drug dose adjustment in patients with renal failure intended to improve pharmacists’ analysis of medication orders in hospitals

Highlights • We compared the diagnostic performances of an alerts system with pharmacists. • The alert system and the pharmacists showed a relatively poor inter-rater agreement. • The alert system fired more appropriate alerts and made fewer errors. • Non-interruptive mode for some alerts can enhanc...

Full description

Saved in:
Bibliographic Details
Published in:International journal of medical informatics (Shannon, Ireland) Ireland), 2013-10, Vol.82 (10), p.964-972
Main Authors: Boussadi, A, Caruba, T, Karras, A, Berdot, S, Degoulet, P, Durieux, P, Sabatier, B
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Highlights • We compared the diagnostic performances of an alerts system with pharmacists. • The alert system and the pharmacists showed a relatively poor inter-rater agreement. • The alert system fired more appropriate alerts and made fewer errors. • Non-interruptive mode for some alerts can enhance the safety of drug prescriptions.