Loading…
Assessment of arsenic, chromium, copper and manganese determination in thermal spring waters by electrothermal atomic absorption spectrometry using various chemical modifiers
Determination of total arsenic, chromium, copper and manganese in hot spring waters containing highly complex matrices and interferences by electrothermal atomic absorption spectrometry (ETAAS) was carried out in the presence of Ni, Pd, Ni + Pd and Ni + Pd + citric acid (CA) as chemical modifiers. P...
Saved in:
Published in: | Analytical methods 2013-01, Vol.5 (3), p.748-754 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Determination of total arsenic, chromium, copper and manganese in hot spring waters containing highly complex matrices and interferences by electrothermal atomic absorption spectrometry (ETAAS) was carried out in the presence of Ni, Pd, Ni + Pd and Ni + Pd + citric acid (CA) as chemical modifiers. Pyrolysis and atomization temperatures of analytes in sample and aqueous standard solutions, atomization and background profiles of analytes in sample solutions were obtained with and without modifiers and compared with each other. Effects of mass and mass ratio of modifiers were also studied. Limit of detection (LOD), limit of quantification (LOQ) and characteristic masses (m sub(o)) of analytes were found in the presence and absence of modifiers. Among the tested modifier mixtures, the Ni + Pd + CA modifier mixture was found to be preferable for the determination of analytes. The lowest LOD and m sub(o) values obtained with Ni + Pd + CA were 0.8 mu g L super(-1) and 32 pg for As, 0.5 mu g L super(-1) and 5.0 pg for Cr, 0.6 mu g L super(-1) and 18 pg for Cu and 0.4 mu g L super(-1) and 4 pg for Mn, respectively. The percent relative error found was below 5% for the determination of the analytes by the proposed method in the certified reference materials (CRMs) of water (Spsww-1 and 1643e). Arsenic in CRMs and sample solutions was also determined by hydride generation atomic absorption spectrometry (HGAAS) for the purpose of comparing with As results obtained by ETAAS. Results of analytes in sample solutions were compared with national and international water quality guidelines such as WHO and US EPA values, as well as literature data. |
---|---|
ISSN: | 1759-9660 1759-9679 |
DOI: | 10.1039/C2AY26291F |