Loading…

Hohlraum glint and laser pre-pulse detector for NIF experiments using velocity interferometer system for any reflector

Laser pre-pulse and early-time laser reflection from the hohlraum wall onto the capsule (termed "glint") can cause capsule imprint and unwanted early-time shocks on indirect drive implosion experiments. In a minor modification to the existing velocity interferometer system for any reflecto...

Full description

Saved in:
Bibliographic Details
Published in:Review of scientific instruments 2014-11, Vol.85 (11), p.11E608-11E608
Main Authors: Moody, J D, Clancy, T J, Frieders, G, Celliers, P M, Ralph, J, Turnbull, D P
Format: Article
Language:English
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c245t-1213a220f2707d6cc7d6b36aa4e04215f219570698e1740cbb1a06eebde8b4e53
container_end_page 11E608
container_issue 11
container_start_page 11E608
container_title Review of scientific instruments
container_volume 85
creator Moody, J D
Clancy, T J
Frieders, G
Celliers, P M
Ralph, J
Turnbull, D P
description Laser pre-pulse and early-time laser reflection from the hohlraum wall onto the capsule (termed "glint") can cause capsule imprint and unwanted early-time shocks on indirect drive implosion experiments. In a minor modification to the existing velocity interferometer system for any reflector diagnostic on NIF a fast-response vacuum photodiode was added to detect this light. The measurements show evidence of laser pre-pulse and possible light reflection off the hohlraum wall and onto the capsule.
doi_str_mv 10.1063/1.4887155
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1628879707</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1628879707</sourcerecordid><originalsourceid>FETCH-LOGICAL-c245t-1213a220f2707d6cc7d6b36aa4e04215f219570698e1740cbb1a06eebde8b4e53</originalsourceid><addsrcrecordid>eNo9kMtOwzAQRS0EoqWw4AeQl7BI8TvpElWUVqpgA-vIcSYlyHlgOxX5e0wpjDQzm3uPZi5C15TMKVH8ns5FlqVUyhM0pSRbJKli_BRNCeEiUanIJujC-w8SS1J6jiZMCk64FFO0X3fv1umhwTtbtwHrtsRWe3C4d5D0g_WASwhgQudwFft5s8Lw1YOrG2iDx4Ov2x3eg-1MHUYcGeAqcF0TTQ770QdoDkbdjthBZQ-oS3RW6ci-Ou4Zels9vi7XyfblabN82CaGCRkSyijXjJGKpSQtlTFxFFxpLYAIRmXF6EKmRC0yoKkgpiioJgqgKCErBEg-Q7e_3N51nwP4kDe1N2CtbqEbfE4Vi8ktIj1K736lxnXex0vzPv6o3ZhTkv_EnNP8GHPU3hyxQ9FA-a_8y5V_A1iVeOM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1628879707</pqid></control><display><type>article</type><title>Hohlraum glint and laser pre-pulse detector for NIF experiments using velocity interferometer system for any reflector</title><source>American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)</source><source>AIP Journals (American Institute of Physics)</source><creator>Moody, J D ; Clancy, T J ; Frieders, G ; Celliers, P M ; Ralph, J ; Turnbull, D P</creator><creatorcontrib>Moody, J D ; Clancy, T J ; Frieders, G ; Celliers, P M ; Ralph, J ; Turnbull, D P</creatorcontrib><description>Laser pre-pulse and early-time laser reflection from the hohlraum wall onto the capsule (termed "glint") can cause capsule imprint and unwanted early-time shocks on indirect drive implosion experiments. In a minor modification to the existing velocity interferometer system for any reflector diagnostic on NIF a fast-response vacuum photodiode was added to detect this light. The measurements show evidence of laser pre-pulse and possible light reflection off the hohlraum wall and onto the capsule.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.4887155</identifier><identifier>PMID: 25430354</identifier><language>eng</language><publisher>United States</publisher><ispartof>Review of scientific instruments, 2014-11, Vol.85 (11), p.11E608-11E608</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c245t-1213a220f2707d6cc7d6b36aa4e04215f219570698e1740cbb1a06eebde8b4e53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,778,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25430354$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Moody, J D</creatorcontrib><creatorcontrib>Clancy, T J</creatorcontrib><creatorcontrib>Frieders, G</creatorcontrib><creatorcontrib>Celliers, P M</creatorcontrib><creatorcontrib>Ralph, J</creatorcontrib><creatorcontrib>Turnbull, D P</creatorcontrib><title>Hohlraum glint and laser pre-pulse detector for NIF experiments using velocity interferometer system for any reflector</title><title>Review of scientific instruments</title><addtitle>Rev Sci Instrum</addtitle><description>Laser pre-pulse and early-time laser reflection from the hohlraum wall onto the capsule (termed "glint") can cause capsule imprint and unwanted early-time shocks on indirect drive implosion experiments. In a minor modification to the existing velocity interferometer system for any reflector diagnostic on NIF a fast-response vacuum photodiode was added to detect this light. The measurements show evidence of laser pre-pulse and possible light reflection off the hohlraum wall and onto the capsule.</description><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNo9kMtOwzAQRS0EoqWw4AeQl7BI8TvpElWUVqpgA-vIcSYlyHlgOxX5e0wpjDQzm3uPZi5C15TMKVH8ns5FlqVUyhM0pSRbJKli_BRNCeEiUanIJujC-w8SS1J6jiZMCk64FFO0X3fv1umhwTtbtwHrtsRWe3C4d5D0g_WASwhgQudwFft5s8Lw1YOrG2iDx4Ov2x3eg-1MHUYcGeAqcF0TTQ770QdoDkbdjthBZQ-oS3RW6ci-Ou4Zels9vi7XyfblabN82CaGCRkSyijXjJGKpSQtlTFxFFxpLYAIRmXF6EKmRC0yoKkgpiioJgqgKCErBEg-Q7e_3N51nwP4kDe1N2CtbqEbfE4Vi8ktIj1K736lxnXex0vzPv6o3ZhTkv_EnNP8GHPU3hyxQ9FA-a_8y5V_A1iVeOM</recordid><startdate>20141101</startdate><enddate>20141101</enddate><creator>Moody, J D</creator><creator>Clancy, T J</creator><creator>Frieders, G</creator><creator>Celliers, P M</creator><creator>Ralph, J</creator><creator>Turnbull, D P</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20141101</creationdate><title>Hohlraum glint and laser pre-pulse detector for NIF experiments using velocity interferometer system for any reflector</title><author>Moody, J D ; Clancy, T J ; Frieders, G ; Celliers, P M ; Ralph, J ; Turnbull, D P</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c245t-1213a220f2707d6cc7d6b36aa4e04215f219570698e1740cbb1a06eebde8b4e53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Moody, J D</creatorcontrib><creatorcontrib>Clancy, T J</creatorcontrib><creatorcontrib>Frieders, G</creatorcontrib><creatorcontrib>Celliers, P M</creatorcontrib><creatorcontrib>Ralph, J</creatorcontrib><creatorcontrib>Turnbull, D P</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Moody, J D</au><au>Clancy, T J</au><au>Frieders, G</au><au>Celliers, P M</au><au>Ralph, J</au><au>Turnbull, D P</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Hohlraum glint and laser pre-pulse detector for NIF experiments using velocity interferometer system for any reflector</atitle><jtitle>Review of scientific instruments</jtitle><addtitle>Rev Sci Instrum</addtitle><date>2014-11-01</date><risdate>2014</risdate><volume>85</volume><issue>11</issue><spage>11E608</spage><epage>11E608</epage><pages>11E608-11E608</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><abstract>Laser pre-pulse and early-time laser reflection from the hohlraum wall onto the capsule (termed "glint") can cause capsule imprint and unwanted early-time shocks on indirect drive implosion experiments. In a minor modification to the existing velocity interferometer system for any reflector diagnostic on NIF a fast-response vacuum photodiode was added to detect this light. The measurements show evidence of laser pre-pulse and possible light reflection off the hohlraum wall and onto the capsule.</abstract><cop>United States</cop><pmid>25430354</pmid><doi>10.1063/1.4887155</doi></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Review of scientific instruments, 2014-11, Vol.85 (11), p.11E608-11E608
issn 0034-6748
1089-7623
language eng
recordid cdi_proquest_miscellaneous_1628879707
source American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list); AIP Journals (American Institute of Physics)
title Hohlraum glint and laser pre-pulse detector for NIF experiments using velocity interferometer system for any reflector
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T08%3A11%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Hohlraum%20glint%20and%20laser%20pre-pulse%20detector%20for%20NIF%20experiments%20using%20velocity%20interferometer%20system%20for%20any%20reflector&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Moody,%20J%20D&rft.date=2014-11-01&rft.volume=85&rft.issue=11&rft.spage=11E608&rft.epage=11E608&rft.pages=11E608-11E608&rft.issn=0034-6748&rft.eissn=1089-7623&rft_id=info:doi/10.1063/1.4887155&rft_dat=%3Cproquest_cross%3E1628879707%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c245t-1213a220f2707d6cc7d6b36aa4e04215f219570698e1740cbb1a06eebde8b4e53%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1628879707&rft_id=info:pmid/25430354&rfr_iscdi=true