The evaluation of the OMOM capsule endoscopy with similar pictures elimination mode

Summary Background and objective The reading of capsule endoscopy (CE) is time-consuming. Thus, several time-saving features have been added to the CE software by different CE companies. However, the similar pictures elimination mode in the OMOM capsule endoscopy software has not been evaluated yet....

Full description

Saved in:
Bibliographic Details
Published in:Clinics and research in hepatology and gastroenterology 2014-12, Vol.38 (6), p.757-762
Main Authors: Xu, Yangzhi, Zhang, Wei, Ye, Shanliang, Han, Zelong, Bai, Yang, Li, Aimin, Chen, Zhenyu, Wan, Tianmo, Liu, Side
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Summary Background and objective The reading of capsule endoscopy (CE) is time-consuming. Thus, several time-saving features have been added to the CE software by different CE companies. However, the similar pictures elimination mode in the OMOM capsule endoscopy software has not been evaluated yet. Our aim is to evaluate the sensitivity and specificity of the similar pictures elimination mode. Methods We retrospectively studied 200 consecutive capsule endoscopy procedures in Nanfang Hospital between April 2012 and July 2012, among which 52 cases were excluded for poor bowel preparation, failure to reach the colon or data missing. All images of the small-bowel were re-evaluated with four different reading modes (conventional mode and three levels of similar pictures elimination mode) by four experienced endoscopists. Then, the reading time, the number of detected lesions, κ value, sensitivity and specificity were compared between 4 methods. Results The mean reading time with levels I to III, respectively, was significantly shorter than with conventional mode ( P < 0.001, conventional mode 33.25 min, level I 24.90 min, level II 20.54 min, level III 14.96 min). The sensitivity between conventional mode and level I were similar (93.8% vs. 87.7%, P = 0.073), while the sensitivity of levels II and III was significantly lower than conventional mode (77.8% vs. 93.8%, 70% vs. 93.8%, respectively). The specificity between all 4 modes were similar (100% for conventional mode, 98.5% for levels I to III). Conclusions Level I reading mode was as efficient as the conventional mode and less time-consuming. Its sensitivity and specificity were similar compared with the conventional mode.
ISSN:2210-7401
2210-741X