Loading…

Experimental based energy performance analysis and life cycle assessment for solar absorption cooling system at University of Californian, Merced

•A double-effect solar absorption cooling test facility was built.•The experimental-based energy performance of the system is investigated.•A life cycle economic and environmental assessment was performed. Traditional air conditioning and heating systems in buildings are fossil fuel based energy sys...

Full description

Saved in:
Bibliographic Details
Published in:Energy and buildings 2014-10, Vol.82, p.746-757
Main Authors: Hang, Yin, Qu, Ming, Winston, Roland, Jiang, Lun, Widyolar, Bennett, Poiry, Heather
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c405t-574896fd332e88cb3ed7eabf3dc296bf1ab56aae04035a68eb4f2bbc3e6b7ee13
cites cdi_FETCH-LOGICAL-c405t-574896fd332e88cb3ed7eabf3dc296bf1ab56aae04035a68eb4f2bbc3e6b7ee13
container_end_page 757
container_issue
container_start_page 746
container_title Energy and buildings
container_volume 82
creator Hang, Yin
Qu, Ming
Winston, Roland
Jiang, Lun
Widyolar, Bennett
Poiry, Heather
description •A double-effect solar absorption cooling test facility was built.•The experimental-based energy performance of the system is investigated.•A life cycle economic and environmental assessment was performed. Traditional air conditioning and heating systems in buildings are fossil fuel based energy systems, which take the main responsible for the carbon emissions. In contrast, using solar energy for air conditioning becomes one of the promising approaches to reduce energy consumptions and negative environmental impacts from buildings. University of California, Merced built a test facility to investigate the technology: solar cooling. The solar system has 54m2 external compound parabolic concentrator (XCPC) solar collectors to drive a 23kW double-effect absorption chiller. This paper first provides the detailed energy performance analysis of the experiments conducted in August, 2012. The data collected from the experiments shows that the system could provide adequate cooling for a test facility between 11AM to 5PM in both sunny and cloudy days. The daily average collector efficiency is at the range of 36% to 39%. The average coefficient of performance (COP) of the LiBr absorption chiller is between 0.91 and 1.02 with an average of 1.0, and the daily solar COP is approximately at 0.374. In addition to the experimental investigation, a detailed life cycle economic and environmental assessment was also performed by comparing the solar systems to the conventional systems in two types of office buildings at three locations at California. Two different solar cooling system configurations were considered: (i) configuration 1 sizes the area of solar collectors and absorption chiller to meet the peak cooling demand, and uses natural gas as the only backup energy source; (ii) configuration 2 sizes the area of solar collectors and absorption chiller to meet half of the peak cooling demand, and uses natural gas as the backup energy source for the absorption chiller, while incorporates an electrical vapor compression chiller to meet the rest half of peak cooling demand. The annual performance predicts that the systems can achieve the annual solar fraction around 55–68%. And the configuration 2 achieves better life cycle economic and environmental performance than the configuration 1. Specifically, the configuration 2 can achieve lower present worth cost during the entire life span than the conventional systems. And both configuration 1 and 2 can reduce the life time carbon
doi_str_mv 10.1016/j.enbuild.2014.07.078
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1651454682</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0378778814006276</els_id><sourcerecordid>1651454682</sourcerecordid><originalsourceid>FETCH-LOGICAL-c405t-574896fd332e88cb3ed7eabf3dc296bf1ab56aae04035a68eb4f2bbc3e6b7ee13</originalsourceid><addsrcrecordid>eNqNkcFqGzEQhveQQtM0j1DQJdBD7UorrVY5lWKStpDSS3MWI-0oyMiSq1mH7mP0jSNj02sLAxLD988M_9917wRfCy70x-0aszvENK17LtSaj63MRXfJ5WhW42jM6-4N0ZZzrodRXHZ_7n7vscYd5hkSc0A4McxYnxbW-qHUHWSPDDKkhSK1z8RSDMj84lPrEyHRUc0ay6gkqAwclbqfY8nMl5JifmK00Iw7BjN7zPEZK8V5YSWwDbRhpeYI-QP7jtXj9LZ7FSARXp_fq-7x_u7n5uvq4ceXb5vPDyuv-DCvhlGZWx0mKXs0xjuJ04jggpx8f6tdEOAGDYBccTmANuhU6J3zErUbEYW86t6f5u5r-XVAmu0ukseUIGM5kBV6EGpQ2vT_gape943kDR1OqK-FqGKw--Yu1MUKbo8J2a09J2SPCVk-tjJNd3NeAeQhhdpsj_RX3Buj5CCPp3w6cdiseY5YLfmILaIpVvSznUr8x6YX236wEg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1642626820</pqid></control><display><type>article</type><title>Experimental based energy performance analysis and life cycle assessment for solar absorption cooling system at University of Californian, Merced</title><source>ScienceDirect Journals</source><creator>Hang, Yin ; Qu, Ming ; Winston, Roland ; Jiang, Lun ; Widyolar, Bennett ; Poiry, Heather</creator><creatorcontrib>Hang, Yin ; Qu, Ming ; Winston, Roland ; Jiang, Lun ; Widyolar, Bennett ; Poiry, Heather</creatorcontrib><description>•A double-effect solar absorption cooling test facility was built.•The experimental-based energy performance of the system is investigated.•A life cycle economic and environmental assessment was performed. Traditional air conditioning and heating systems in buildings are fossil fuel based energy systems, which take the main responsible for the carbon emissions. In contrast, using solar energy for air conditioning becomes one of the promising approaches to reduce energy consumptions and negative environmental impacts from buildings. University of California, Merced built a test facility to investigate the technology: solar cooling. The solar system has 54m2 external compound parabolic concentrator (XCPC) solar collectors to drive a 23kW double-effect absorption chiller. This paper first provides the detailed energy performance analysis of the experiments conducted in August, 2012. The data collected from the experiments shows that the system could provide adequate cooling for a test facility between 11AM to 5PM in both sunny and cloudy days. The daily average collector efficiency is at the range of 36% to 39%. The average coefficient of performance (COP) of the LiBr absorption chiller is between 0.91 and 1.02 with an average of 1.0, and the daily solar COP is approximately at 0.374. In addition to the experimental investigation, a detailed life cycle economic and environmental assessment was also performed by comparing the solar systems to the conventional systems in two types of office buildings at three locations at California. Two different solar cooling system configurations were considered: (i) configuration 1 sizes the area of solar collectors and absorption chiller to meet the peak cooling demand, and uses natural gas as the only backup energy source; (ii) configuration 2 sizes the area of solar collectors and absorption chiller to meet half of the peak cooling demand, and uses natural gas as the backup energy source for the absorption chiller, while incorporates an electrical vapor compression chiller to meet the rest half of peak cooling demand. The annual performance predicts that the systems can achieve the annual solar fraction around 55–68%. And the configuration 2 achieves better life cycle economic and environmental performance than the configuration 1. Specifically, the configuration 2 can achieve lower present worth cost during the entire life span than the conventional systems. And both configuration 1 and 2 can reduce the life time carbon footprint by 35–70%.</description><identifier>ISSN: 0378-7788</identifier><identifier>DOI: 10.1016/j.enbuild.2014.07.078</identifier><identifier>CODEN: ENEBDR</identifier><language>eng</language><publisher>Oxford: Elsevier B.V</publisher><subject>Applied sciences ; Building economics. Cost ; Building technical equipments ; Buildings ; Buildings. Public works ; Computation methods. Tables. Charts ; Cooling ; Cooling systems ; Economic analysis ; Economics ; Energy management and energy conservation in building ; Environmental engineering ; Exact sciences and technology ; Experiment ; External compound parabolic concentrator ; Life cycle assessment ; Life cycle engineering ; Measurements. Technique of testing ; Natural gas ; Solar absorption cooling and heating ; Solar collectors ; Solar system ; Structural analysis. Stresses</subject><ispartof>Energy and buildings, 2014-10, Vol.82, p.746-757</ispartof><rights>2014 Elsevier B.V.</rights><rights>2015 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c405t-574896fd332e88cb3ed7eabf3dc296bf1ab56aae04035a68eb4f2bbc3e6b7ee13</citedby><cites>FETCH-LOGICAL-c405t-574896fd332e88cb3ed7eabf3dc296bf1ab56aae04035a68eb4f2bbc3e6b7ee13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=28843532$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Hang, Yin</creatorcontrib><creatorcontrib>Qu, Ming</creatorcontrib><creatorcontrib>Winston, Roland</creatorcontrib><creatorcontrib>Jiang, Lun</creatorcontrib><creatorcontrib>Widyolar, Bennett</creatorcontrib><creatorcontrib>Poiry, Heather</creatorcontrib><title>Experimental based energy performance analysis and life cycle assessment for solar absorption cooling system at University of Californian, Merced</title><title>Energy and buildings</title><description>•A double-effect solar absorption cooling test facility was built.•The experimental-based energy performance of the system is investigated.•A life cycle economic and environmental assessment was performed. Traditional air conditioning and heating systems in buildings are fossil fuel based energy systems, which take the main responsible for the carbon emissions. In contrast, using solar energy for air conditioning becomes one of the promising approaches to reduce energy consumptions and negative environmental impacts from buildings. University of California, Merced built a test facility to investigate the technology: solar cooling. The solar system has 54m2 external compound parabolic concentrator (XCPC) solar collectors to drive a 23kW double-effect absorption chiller. This paper first provides the detailed energy performance analysis of the experiments conducted in August, 2012. The data collected from the experiments shows that the system could provide adequate cooling for a test facility between 11AM to 5PM in both sunny and cloudy days. The daily average collector efficiency is at the range of 36% to 39%. The average coefficient of performance (COP) of the LiBr absorption chiller is between 0.91 and 1.02 with an average of 1.0, and the daily solar COP is approximately at 0.374. In addition to the experimental investigation, a detailed life cycle economic and environmental assessment was also performed by comparing the solar systems to the conventional systems in two types of office buildings at three locations at California. Two different solar cooling system configurations were considered: (i) configuration 1 sizes the area of solar collectors and absorption chiller to meet the peak cooling demand, and uses natural gas as the only backup energy source; (ii) configuration 2 sizes the area of solar collectors and absorption chiller to meet half of the peak cooling demand, and uses natural gas as the backup energy source for the absorption chiller, while incorporates an electrical vapor compression chiller to meet the rest half of peak cooling demand. The annual performance predicts that the systems can achieve the annual solar fraction around 55–68%. And the configuration 2 achieves better life cycle economic and environmental performance than the configuration 1. Specifically, the configuration 2 can achieve lower present worth cost during the entire life span than the conventional systems. And both configuration 1 and 2 can reduce the life time carbon footprint by 35–70%.</description><subject>Applied sciences</subject><subject>Building economics. Cost</subject><subject>Building technical equipments</subject><subject>Buildings</subject><subject>Buildings. Public works</subject><subject>Computation methods. Tables. Charts</subject><subject>Cooling</subject><subject>Cooling systems</subject><subject>Economic analysis</subject><subject>Economics</subject><subject>Energy management and energy conservation in building</subject><subject>Environmental engineering</subject><subject>Exact sciences and technology</subject><subject>Experiment</subject><subject>External compound parabolic concentrator</subject><subject>Life cycle assessment</subject><subject>Life cycle engineering</subject><subject>Measurements. Technique of testing</subject><subject>Natural gas</subject><subject>Solar absorption cooling and heating</subject><subject>Solar collectors</subject><subject>Solar system</subject><subject>Structural analysis. Stresses</subject><issn>0378-7788</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNqNkcFqGzEQhveQQtM0j1DQJdBD7UorrVY5lWKStpDSS3MWI-0oyMiSq1mH7mP0jSNj02sLAxLD988M_9917wRfCy70x-0aszvENK17LtSaj63MRXfJ5WhW42jM6-4N0ZZzrodRXHZ_7n7vscYd5hkSc0A4McxYnxbW-qHUHWSPDDKkhSK1z8RSDMj84lPrEyHRUc0ay6gkqAwclbqfY8nMl5JifmK00Iw7BjN7zPEZK8V5YSWwDbRhpeYI-QP7jtXj9LZ7FSARXp_fq-7x_u7n5uvq4ceXb5vPDyuv-DCvhlGZWx0mKXs0xjuJ04jggpx8f6tdEOAGDYBccTmANuhU6J3zErUbEYW86t6f5u5r-XVAmu0ukseUIGM5kBV6EGpQ2vT_gape943kDR1OqK-FqGKw--Yu1MUKbo8J2a09J2SPCVk-tjJNd3NeAeQhhdpsj_RX3Buj5CCPp3w6cdiseY5YLfmILaIpVvSznUr8x6YX236wEg</recordid><startdate>20141001</startdate><enddate>20141001</enddate><creator>Hang, Yin</creator><creator>Qu, Ming</creator><creator>Winston, Roland</creator><creator>Jiang, Lun</creator><creator>Widyolar, Bennett</creator><creator>Poiry, Heather</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope><scope>7SU</scope><scope>7TB</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>20141001</creationdate><title>Experimental based energy performance analysis and life cycle assessment for solar absorption cooling system at University of Californian, Merced</title><author>Hang, Yin ; Qu, Ming ; Winston, Roland ; Jiang, Lun ; Widyolar, Bennett ; Poiry, Heather</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c405t-574896fd332e88cb3ed7eabf3dc296bf1ab56aae04035a68eb4f2bbc3e6b7ee13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Applied sciences</topic><topic>Building economics. Cost</topic><topic>Building technical equipments</topic><topic>Buildings</topic><topic>Buildings. Public works</topic><topic>Computation methods. Tables. Charts</topic><topic>Cooling</topic><topic>Cooling systems</topic><topic>Economic analysis</topic><topic>Economics</topic><topic>Energy management and energy conservation in building</topic><topic>Environmental engineering</topic><topic>Exact sciences and technology</topic><topic>Experiment</topic><topic>External compound parabolic concentrator</topic><topic>Life cycle assessment</topic><topic>Life cycle engineering</topic><topic>Measurements. Technique of testing</topic><topic>Natural gas</topic><topic>Solar absorption cooling and heating</topic><topic>Solar collectors</topic><topic>Solar system</topic><topic>Structural analysis. Stresses</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hang, Yin</creatorcontrib><creatorcontrib>Qu, Ming</creatorcontrib><creatorcontrib>Winston, Roland</creatorcontrib><creatorcontrib>Jiang, Lun</creatorcontrib><creatorcontrib>Widyolar, Bennett</creatorcontrib><creatorcontrib>Poiry, Heather</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><collection>Environmental Engineering Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Energy and buildings</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hang, Yin</au><au>Qu, Ming</au><au>Winston, Roland</au><au>Jiang, Lun</au><au>Widyolar, Bennett</au><au>Poiry, Heather</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Experimental based energy performance analysis and life cycle assessment for solar absorption cooling system at University of Californian, Merced</atitle><jtitle>Energy and buildings</jtitle><date>2014-10-01</date><risdate>2014</risdate><volume>82</volume><spage>746</spage><epage>757</epage><pages>746-757</pages><issn>0378-7788</issn><coden>ENEBDR</coden><abstract>•A double-effect solar absorption cooling test facility was built.•The experimental-based energy performance of the system is investigated.•A life cycle economic and environmental assessment was performed. Traditional air conditioning and heating systems in buildings are fossil fuel based energy systems, which take the main responsible for the carbon emissions. In contrast, using solar energy for air conditioning becomes one of the promising approaches to reduce energy consumptions and negative environmental impacts from buildings. University of California, Merced built a test facility to investigate the technology: solar cooling. The solar system has 54m2 external compound parabolic concentrator (XCPC) solar collectors to drive a 23kW double-effect absorption chiller. This paper first provides the detailed energy performance analysis of the experiments conducted in August, 2012. The data collected from the experiments shows that the system could provide adequate cooling for a test facility between 11AM to 5PM in both sunny and cloudy days. The daily average collector efficiency is at the range of 36% to 39%. The average coefficient of performance (COP) of the LiBr absorption chiller is between 0.91 and 1.02 with an average of 1.0, and the daily solar COP is approximately at 0.374. In addition to the experimental investigation, a detailed life cycle economic and environmental assessment was also performed by comparing the solar systems to the conventional systems in two types of office buildings at three locations at California. Two different solar cooling system configurations were considered: (i) configuration 1 sizes the area of solar collectors and absorption chiller to meet the peak cooling demand, and uses natural gas as the only backup energy source; (ii) configuration 2 sizes the area of solar collectors and absorption chiller to meet half of the peak cooling demand, and uses natural gas as the backup energy source for the absorption chiller, while incorporates an electrical vapor compression chiller to meet the rest half of peak cooling demand. The annual performance predicts that the systems can achieve the annual solar fraction around 55–68%. And the configuration 2 achieves better life cycle economic and environmental performance than the configuration 1. Specifically, the configuration 2 can achieve lower present worth cost during the entire life span than the conventional systems. And both configuration 1 and 2 can reduce the life time carbon footprint by 35–70%.</abstract><cop>Oxford</cop><pub>Elsevier B.V</pub><doi>10.1016/j.enbuild.2014.07.078</doi><tpages>12</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0378-7788
ispartof Energy and buildings, 2014-10, Vol.82, p.746-757
issn 0378-7788
language eng
recordid cdi_proquest_miscellaneous_1651454682
source ScienceDirect Journals
subjects Applied sciences
Building economics. Cost
Building technical equipments
Buildings
Buildings. Public works
Computation methods. Tables. Charts
Cooling
Cooling systems
Economic analysis
Economics
Energy management and energy conservation in building
Environmental engineering
Exact sciences and technology
Experiment
External compound parabolic concentrator
Life cycle assessment
Life cycle engineering
Measurements. Technique of testing
Natural gas
Solar absorption cooling and heating
Solar collectors
Solar system
Structural analysis. Stresses
title Experimental based energy performance analysis and life cycle assessment for solar absorption cooling system at University of Californian, Merced
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T17%3A11%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Experimental%20based%20energy%20performance%20analysis%20and%20life%20cycle%20assessment%20for%20solar%20absorption%20cooling%20system%20at%20University%20of%20Californian,%20Merced&rft.jtitle=Energy%20and%20buildings&rft.au=Hang,%20Yin&rft.date=2014-10-01&rft.volume=82&rft.spage=746&rft.epage=757&rft.pages=746-757&rft.issn=0378-7788&rft.coden=ENEBDR&rft_id=info:doi/10.1016/j.enbuild.2014.07.078&rft_dat=%3Cproquest_cross%3E1651454682%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c405t-574896fd332e88cb3ed7eabf3dc296bf1ab56aae04035a68eb4f2bbc3e6b7ee13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1642626820&rft_id=info:pmid/&rfr_iscdi=true