Loading…
Review of stationary phases for microelectromechanical systems in gas chromatography: feasibility and separations
This review covers the recent development of stationary phases for chip-based gas chromatography (GC). Portable systems for rapid and reliable analysis are urgently needed. One way to achieve this is to miniaturize the entire analysis. Because the column is the central component of the GC system and...
Saved in:
Published in: | Analytical and bioanalytical chemistry 2014-02, Vol.406 (4), p.981-994 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c580t-59bcb801daa36a83915f81f4b1b0aae2d9b5c512c662ffef91d079da222f27e03 |
---|---|
cites | cdi_FETCH-LOGICAL-c580t-59bcb801daa36a83915f81f4b1b0aae2d9b5c512c662ffef91d079da222f27e03 |
container_end_page | 994 |
container_issue | 4 |
container_start_page | 981 |
container_title | Analytical and bioanalytical chemistry |
container_volume | 406 |
creator | Azzouz, I. Vial, J. Thiébaut, D. Haudebourg, R. Danaie, K. Sassiat, P. Breviere, J. |
description | This review covers the recent development of stationary phases for chip-based gas chromatography (GC). Portable systems for rapid and reliable analysis are urgently needed. One way to achieve this is to miniaturize the entire analysis. Because the column is the central component of the GC system and determines the feasibility and quality of separation, this review focuses on stationary phases reported in the literature and their use in different fields during the last two decades, with emphasis on different methods for introducing the stationary phase into the GC column. |
doi_str_mv | 10.1007/s00216-013-7168-7 |
format | article |
fullrecord | <record><control><sourceid>gale_proqu</sourceid><recordid>TN_cdi_proquest_miscellaneous_1660054894</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A386268820</galeid><sourcerecordid>A386268820</sourcerecordid><originalsourceid>FETCH-LOGICAL-c580t-59bcb801daa36a83915f81f4b1b0aae2d9b5c512c662ffef91d079da222f27e03</originalsourceid><addsrcrecordid>eNqNktFr1TAUxosobk7_AF8k4IsvnSdpkya-jeFUGAiiz-U0Pbk3o23ukt7J_e9N1zlEEC95SMj5nY-Pc76ieM3hnAM07xOA4KoEXpUNV7psnhSnXHFdCiXh6eO7FifFi5RuALjUXD0vTkRlhOEGTovbb3Tn6ScLjqUZZx8mjAe222KixFyIbPQ2BhrIzjGMZLc4eYsDS4c005iYn9gGE7PbXMU5bCLutocPzBEm3_nBzweGU88S7TDey6eXxTOHQ6JXD_dZ8ePq4_fLz-X1109fLi-uSys1zKU0ne008B6xUqgrw6XT3NUd7wCRRG86aSUXVinhHDnDe2hMj0IIJxqC6qx4t-ruYrjdU5rb0SdLw4AThX1quVIAstamPhaV-ghUqgaU1kIegUoOCnSl_4_WRijTmLrJ6Nu_0Juwj1OeZLbZgGjqGqpMna_UBgdq_eTCHNHm01NeaJjI-fx_UWklFrPLtPjakLedUiTX7qIfcxZaDu0StnYNW5vD1i5haxcrbx6s7LuR-seO3-nKgFiBlEvThuIfXv-p-gtkx96p</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1670274403</pqid></control><display><type>article</type><title>Review of stationary phases for microelectromechanical systems in gas chromatography: feasibility and separations</title><source>Springer Nature</source><creator>Azzouz, I. ; Vial, J. ; Thiébaut, D. ; Haudebourg, R. ; Danaie, K. ; Sassiat, P. ; Breviere, J.</creator><creatorcontrib>Azzouz, I. ; Vial, J. ; Thiébaut, D. ; Haudebourg, R. ; Danaie, K. ; Sassiat, P. ; Breviere, J.</creatorcontrib><description>This review covers the recent development of stationary phases for chip-based gas chromatography (GC). Portable systems for rapid and reliable analysis are urgently needed. One way to achieve this is to miniaturize the entire analysis. Because the column is the central component of the GC system and determines the feasibility and quality of separation, this review focuses on stationary phases reported in the literature and their use in different fields during the last two decades, with emphasis on different methods for introducing the stationary phase into the GC column.</description><identifier>ISSN: 1618-2642</identifier><identifier>EISSN: 1618-2650</identifier><identifier>DOI: 10.1007/s00216-013-7168-7</identifier><identifier>PMID: 23929190</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer Berlin Heidelberg</publisher><subject>Analytical Chemistry ; Biochemistry ; Characterization and Evaluation of Materials ; Chemistry ; Chemistry and Materials Science ; Chromatography ; Equipment and supplies ; Feasibility ; Food Science ; Gas chromatography ; Laboratory Medicine ; Mathematical analysis ; Microelectromechanical systems ; Monitoring/Environmental Analysis ; Phases ; Portability ; Review ; Sensors ; Separation ; Silicon wafers ; Technology application</subject><ispartof>Analytical and bioanalytical chemistry, 2014-02, Vol.406 (4), p.981-994</ispartof><rights>Springer-Verlag Berlin Heidelberg 2013</rights><rights>COPYRIGHT 2014 Springer</rights><rights>Springer-Verlag Berlin Heidelberg 2014</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c580t-59bcb801daa36a83915f81f4b1b0aae2d9b5c512c662ffef91d079da222f27e03</citedby><cites>FETCH-LOGICAL-c580t-59bcb801daa36a83915f81f4b1b0aae2d9b5c512c662ffef91d079da222f27e03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23929190$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Azzouz, I.</creatorcontrib><creatorcontrib>Vial, J.</creatorcontrib><creatorcontrib>Thiébaut, D.</creatorcontrib><creatorcontrib>Haudebourg, R.</creatorcontrib><creatorcontrib>Danaie, K.</creatorcontrib><creatorcontrib>Sassiat, P.</creatorcontrib><creatorcontrib>Breviere, J.</creatorcontrib><title>Review of stationary phases for microelectromechanical systems in gas chromatography: feasibility and separations</title><title>Analytical and bioanalytical chemistry</title><addtitle>Anal Bioanal Chem</addtitle><addtitle>Anal Bioanal Chem</addtitle><description>This review covers the recent development of stationary phases for chip-based gas chromatography (GC). Portable systems for rapid and reliable analysis are urgently needed. One way to achieve this is to miniaturize the entire analysis. Because the column is the central component of the GC system and determines the feasibility and quality of separation, this review focuses on stationary phases reported in the literature and their use in different fields during the last two decades, with emphasis on different methods for introducing the stationary phase into the GC column.</description><subject>Analytical Chemistry</subject><subject>Biochemistry</subject><subject>Characterization and Evaluation of Materials</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Chromatography</subject><subject>Equipment and supplies</subject><subject>Feasibility</subject><subject>Food Science</subject><subject>Gas chromatography</subject><subject>Laboratory Medicine</subject><subject>Mathematical analysis</subject><subject>Microelectromechanical systems</subject><subject>Monitoring/Environmental Analysis</subject><subject>Phases</subject><subject>Portability</subject><subject>Review</subject><subject>Sensors</subject><subject>Separation</subject><subject>Silicon wafers</subject><subject>Technology application</subject><issn>1618-2642</issn><issn>1618-2650</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNqNktFr1TAUxosobk7_AF8k4IsvnSdpkya-jeFUGAiiz-U0Pbk3o23ukt7J_e9N1zlEEC95SMj5nY-Pc76ieM3hnAM07xOA4KoEXpUNV7psnhSnXHFdCiXh6eO7FifFi5RuALjUXD0vTkRlhOEGTovbb3Tn6ScLjqUZZx8mjAe222KixFyIbPQ2BhrIzjGMZLc4eYsDS4c005iYn9gGE7PbXMU5bCLutocPzBEm3_nBzweGU88S7TDey6eXxTOHQ6JXD_dZ8ePq4_fLz-X1109fLi-uSys1zKU0ne008B6xUqgrw6XT3NUd7wCRRG86aSUXVinhHDnDe2hMj0IIJxqC6qx4t-ruYrjdU5rb0SdLw4AThX1quVIAstamPhaV-ghUqgaU1kIegUoOCnSl_4_WRijTmLrJ6Nu_0Juwj1OeZLbZgGjqGqpMna_UBgdq_eTCHNHm01NeaJjI-fx_UWklFrPLtPjakLedUiTX7qIfcxZaDu0StnYNW5vD1i5haxcrbx6s7LuR-seO3-nKgFiBlEvThuIfXv-p-gtkx96p</recordid><startdate>20140201</startdate><enddate>20140201</enddate><creator>Azzouz, I.</creator><creator>Vial, J.</creator><creator>Thiébaut, D.</creator><creator>Haudebourg, R.</creator><creator>Danaie, K.</creator><creator>Sassiat, P.</creator><creator>Breviere, J.</creator><general>Springer Berlin Heidelberg</general><general>Springer</general><general>Springer Nature B.V</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7U5</scope><scope>7U7</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8BQ</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>C1K</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>F28</scope><scope>FR3</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>H8D</scope><scope>H8G</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>JQ2</scope><scope>K9.</scope><scope>KB.</scope><scope>KR7</scope><scope>L7M</scope><scope>LK8</scope><scope>L~C</scope><scope>L~D</scope><scope>M0S</scope><scope>M1P</scope><scope>M7P</scope><scope>P64</scope><scope>PDBOC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>7X8</scope><scope>7QH</scope><scope>7UA</scope></search><sort><creationdate>20140201</creationdate><title>Review of stationary phases for microelectromechanical systems in gas chromatography: feasibility and separations</title><author>Azzouz, I. ; Vial, J. ; Thiébaut, D. ; Haudebourg, R. ; Danaie, K. ; Sassiat, P. ; Breviere, J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c580t-59bcb801daa36a83915f81f4b1b0aae2d9b5c512c662ffef91d079da222f27e03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Analytical Chemistry</topic><topic>Biochemistry</topic><topic>Characterization and Evaluation of Materials</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Chromatography</topic><topic>Equipment and supplies</topic><topic>Feasibility</topic><topic>Food Science</topic><topic>Gas chromatography</topic><topic>Laboratory Medicine</topic><topic>Mathematical analysis</topic><topic>Microelectromechanical systems</topic><topic>Monitoring/Environmental Analysis</topic><topic>Phases</topic><topic>Portability</topic><topic>Review</topic><topic>Sensors</topic><topic>Separation</topic><topic>Silicon wafers</topic><topic>Technology application</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Azzouz, I.</creatorcontrib><creatorcontrib>Vial, J.</creatorcontrib><creatorcontrib>Thiébaut, D.</creatorcontrib><creatorcontrib>Haudebourg, R.</creatorcontrib><creatorcontrib>Danaie, K.</creatorcontrib><creatorcontrib>Sassiat, P.</creatorcontrib><creatorcontrib>Breviere, J.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>ProQuest_Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>SciTech Premium Collection (Proquest) (PQ_SDU_P3)</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Materials Science Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>ProQuest Biological Science Collection</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>ProQuest Biological Science Journals</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Materials science collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>MEDLINE - Academic</collection><collection>Aqualine</collection><collection>Water Resources Abstracts</collection><jtitle>Analytical and bioanalytical chemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Azzouz, I.</au><au>Vial, J.</au><au>Thiébaut, D.</au><au>Haudebourg, R.</au><au>Danaie, K.</au><au>Sassiat, P.</au><au>Breviere, J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Review of stationary phases for microelectromechanical systems in gas chromatography: feasibility and separations</atitle><jtitle>Analytical and bioanalytical chemistry</jtitle><stitle>Anal Bioanal Chem</stitle><addtitle>Anal Bioanal Chem</addtitle><date>2014-02-01</date><risdate>2014</risdate><volume>406</volume><issue>4</issue><spage>981</spage><epage>994</epage><pages>981-994</pages><issn>1618-2642</issn><eissn>1618-2650</eissn><abstract>This review covers the recent development of stationary phases for chip-based gas chromatography (GC). Portable systems for rapid and reliable analysis are urgently needed. One way to achieve this is to miniaturize the entire analysis. Because the column is the central component of the GC system and determines the feasibility and quality of separation, this review focuses on stationary phases reported in the literature and their use in different fields during the last two decades, with emphasis on different methods for introducing the stationary phase into the GC column.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer Berlin Heidelberg</pub><pmid>23929190</pmid><doi>10.1007/s00216-013-7168-7</doi><tpages>14</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1618-2642 |
ispartof | Analytical and bioanalytical chemistry, 2014-02, Vol.406 (4), p.981-994 |
issn | 1618-2642 1618-2650 |
language | eng |
recordid | cdi_proquest_miscellaneous_1660054894 |
source | Springer Nature |
subjects | Analytical Chemistry Biochemistry Characterization and Evaluation of Materials Chemistry Chemistry and Materials Science Chromatography Equipment and supplies Feasibility Food Science Gas chromatography Laboratory Medicine Mathematical analysis Microelectromechanical systems Monitoring/Environmental Analysis Phases Portability Review Sensors Separation Silicon wafers Technology application |
title | Review of stationary phases for microelectromechanical systems in gas chromatography: feasibility and separations |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T01%3A17%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Review%20of%20stationary%20phases%20for%20microelectromechanical%20systems%20in%20gas%20chromatography:%20feasibility%20and%20separations&rft.jtitle=Analytical%20and%20bioanalytical%20chemistry&rft.au=Azzouz,%20I.&rft.date=2014-02-01&rft.volume=406&rft.issue=4&rft.spage=981&rft.epage=994&rft.pages=981-994&rft.issn=1618-2642&rft.eissn=1618-2650&rft_id=info:doi/10.1007/s00216-013-7168-7&rft_dat=%3Cgale_proqu%3EA386268820%3C/gale_proqu%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c580t-59bcb801daa36a83915f81f4b1b0aae2d9b5c512c662ffef91d079da222f27e03%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1670274403&rft_id=info:pmid/23929190&rft_galeid=A386268820&rfr_iscdi=true |