Loading…
Variation of the noise levels in the baseline of an adsorption microcalorimeter
This work shows the results obtained to determine the noise in the baseline of a specially designed Tian Calvet-Type adsorption microcalorimeter. The results show that noise levels vary from 0.5 to 10 μV, which were evaluated varying the electrical work and the micro calorimeter surrounding temperat...
Saved in:
Published in: | Journal of thermal analysis and calorimetry 2009-08, Vol.97 (2), p.705-709 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c394t-a81e46a72b81dfeafefefa8091ca91e75000b71a7812f71191f2eb03f2c2acb13 |
---|---|
cites | cdi_FETCH-LOGICAL-c394t-a81e46a72b81dfeafefefa8091ca91e75000b71a7812f71191f2eb03f2c2acb13 |
container_end_page | 709 |
container_issue | 2 |
container_start_page | 705 |
container_title | Journal of thermal analysis and calorimetry |
container_volume | 97 |
creator | García-Cuello, V. Moreno-Pirajan, J. C. Giraldo-Gutiérrez, L. Sapag, K. Zgrablich, G. |
description | This work shows the results obtained to determine the noise in the baseline of a specially designed Tian Calvet-Type adsorption microcalorimeter. The results show that noise levels vary from 0.5 to 10 μV, which were evaluated varying the electrical work and the micro calorimeter surrounding temperature. Relationships can be seen between the variables employed in the observation of stability, temperature, potency levels and generated noise. |
doi_str_mv | 10.1007/s10973-009-0333-8 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1671260406</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1671260406</sourcerecordid><originalsourceid>FETCH-LOGICAL-c394t-a81e46a72b81dfeafefefa8091ca91e75000b71a7812f71191f2eb03f2c2acb13</originalsourceid><addsrcrecordid>eNp9kE1LxDAQhosouOj-AG-9CF6qM-m2SY6y-AXCXtRrmHYnGukma9IV_PdmP_Aoc5ghed6XmbcoLhCuEUDeJAQt6wpAV1DXdaWOigk2SlVCi_Y4z3WeW2zgtJim5DoQCK1ulJ4UizeKjkYXfBlsOX5w6YNLXA78zUMqnd-9dZR4cJ63DPmSlinE9U60cn0MPQ0huhWPHM-LE0tD4umhnxWv93cv88fqefHwNL99rvpaz8aKFPKsJSk6hUvLZDkXKdDYk0aWDQB0EkkqFFYiarSCO6it6AX1HdZnxdXedx3D14bTaFYu9TwM5DlsksFWomhhBm1GcY_mTVOKbM06L0vxxyCYbX5mn5_J-ZltfkZlzeXBnlK-zkbyvUt_QiFANk0DmRN7LuUv_87RfIZN9Pnyf8x_Af5sgFg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1671260406</pqid></control><display><type>article</type><title>Variation of the noise levels in the baseline of an adsorption microcalorimeter</title><source>Springer Nature</source><creator>García-Cuello, V. ; Moreno-Pirajan, J. C. ; Giraldo-Gutiérrez, L. ; Sapag, K. ; Zgrablich, G.</creator><creatorcontrib>García-Cuello, V. ; Moreno-Pirajan, J. C. ; Giraldo-Gutiérrez, L. ; Sapag, K. ; Zgrablich, G.</creatorcontrib><description>This work shows the results obtained to determine the noise in the baseline of a specially designed Tian Calvet-Type adsorption microcalorimeter. The results show that noise levels vary from 0.5 to 10 μV, which were evaluated varying the electrical work and the micro calorimeter surrounding temperature. Relationships can be seen between the variables employed in the observation of stability, temperature, potency levels and generated noise.</description><identifier>ISSN: 1388-6150</identifier><identifier>EISSN: 1588-2926</identifier><identifier>EISSN: 1572-8943</identifier><identifier>DOI: 10.1007/s10973-009-0333-8</identifier><language>eng</language><publisher>Dordrecht: Springer Netherlands</publisher><subject>Adsorption ; Analytical Chemistry ; Calorimetry ; Chemical and thermal methods ; Chemistry ; Chemistry and Materials Science ; Exact sciences and technology ; Inorganic Chemistry ; Measurement Science and Instrumentation ; Microcalorimeters ; Noise ; Noise levels ; Physical Chemistry ; Polymer Sciences ; Stability ; Thermal analysis</subject><ispartof>Journal of thermal analysis and calorimetry, 2009-08, Vol.97 (2), p.705-709</ispartof><rights>Akadémiai Kiadó, Budapest, Hungary 2009</rights><rights>2015 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c394t-a81e46a72b81dfeafefefa8091ca91e75000b71a7812f71191f2eb03f2c2acb13</citedby><cites>FETCH-LOGICAL-c394t-a81e46a72b81dfeafefefa8091ca91e75000b71a7812f71191f2eb03f2c2acb13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=22075550$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>García-Cuello, V.</creatorcontrib><creatorcontrib>Moreno-Pirajan, J. C.</creatorcontrib><creatorcontrib>Giraldo-Gutiérrez, L.</creatorcontrib><creatorcontrib>Sapag, K.</creatorcontrib><creatorcontrib>Zgrablich, G.</creatorcontrib><title>Variation of the noise levels in the baseline of an adsorption microcalorimeter</title><title>Journal of thermal analysis and calorimetry</title><addtitle>J Therm Anal Calorim</addtitle><description>This work shows the results obtained to determine the noise in the baseline of a specially designed Tian Calvet-Type adsorption microcalorimeter. The results show that noise levels vary from 0.5 to 10 μV, which were evaluated varying the electrical work and the micro calorimeter surrounding temperature. Relationships can be seen between the variables employed in the observation of stability, temperature, potency levels and generated noise.</description><subject>Adsorption</subject><subject>Analytical Chemistry</subject><subject>Calorimetry</subject><subject>Chemical and thermal methods</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Exact sciences and technology</subject><subject>Inorganic Chemistry</subject><subject>Measurement Science and Instrumentation</subject><subject>Microcalorimeters</subject><subject>Noise</subject><subject>Noise levels</subject><subject>Physical Chemistry</subject><subject>Polymer Sciences</subject><subject>Stability</subject><subject>Thermal analysis</subject><issn>1388-6150</issn><issn>1588-2926</issn><issn>1572-8943</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LxDAQhosouOj-AG-9CF6qM-m2SY6y-AXCXtRrmHYnGukma9IV_PdmP_Aoc5ghed6XmbcoLhCuEUDeJAQt6wpAV1DXdaWOigk2SlVCi_Y4z3WeW2zgtJim5DoQCK1ulJ4UizeKjkYXfBlsOX5w6YNLXA78zUMqnd-9dZR4cJ63DPmSlinE9U60cn0MPQ0huhWPHM-LE0tD4umhnxWv93cv88fqefHwNL99rvpaz8aKFPKsJSk6hUvLZDkXKdDYk0aWDQB0EkkqFFYiarSCO6it6AX1HdZnxdXedx3D14bTaFYu9TwM5DlsksFWomhhBm1GcY_mTVOKbM06L0vxxyCYbX5mn5_J-ZltfkZlzeXBnlK-zkbyvUt_QiFANk0DmRN7LuUv_87RfIZN9Pnyf8x_Af5sgFg</recordid><startdate>20090801</startdate><enddate>20090801</enddate><creator>García-Cuello, V.</creator><creator>Moreno-Pirajan, J. C.</creator><creator>Giraldo-Gutiérrez, L.</creator><creator>Sapag, K.</creator><creator>Zgrablich, G.</creator><general>Springer Netherlands</general><general>Springer</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>20090801</creationdate><title>Variation of the noise levels in the baseline of an adsorption microcalorimeter</title><author>García-Cuello, V. ; Moreno-Pirajan, J. C. ; Giraldo-Gutiérrez, L. ; Sapag, K. ; Zgrablich, G.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c394t-a81e46a72b81dfeafefefa8091ca91e75000b71a7812f71191f2eb03f2c2acb13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Adsorption</topic><topic>Analytical Chemistry</topic><topic>Calorimetry</topic><topic>Chemical and thermal methods</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Exact sciences and technology</topic><topic>Inorganic Chemistry</topic><topic>Measurement Science and Instrumentation</topic><topic>Microcalorimeters</topic><topic>Noise</topic><topic>Noise levels</topic><topic>Physical Chemistry</topic><topic>Polymer Sciences</topic><topic>Stability</topic><topic>Thermal analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>García-Cuello, V.</creatorcontrib><creatorcontrib>Moreno-Pirajan, J. C.</creatorcontrib><creatorcontrib>Giraldo-Gutiérrez, L.</creatorcontrib><creatorcontrib>Sapag, K.</creatorcontrib><creatorcontrib>Zgrablich, G.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of thermal analysis and calorimetry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>García-Cuello, V.</au><au>Moreno-Pirajan, J. C.</au><au>Giraldo-Gutiérrez, L.</au><au>Sapag, K.</au><au>Zgrablich, G.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Variation of the noise levels in the baseline of an adsorption microcalorimeter</atitle><jtitle>Journal of thermal analysis and calorimetry</jtitle><stitle>J Therm Anal Calorim</stitle><date>2009-08-01</date><risdate>2009</risdate><volume>97</volume><issue>2</issue><spage>705</spage><epage>709</epage><pages>705-709</pages><issn>1388-6150</issn><eissn>1588-2926</eissn><eissn>1572-8943</eissn><abstract>This work shows the results obtained to determine the noise in the baseline of a specially designed Tian Calvet-Type adsorption microcalorimeter. The results show that noise levels vary from 0.5 to 10 μV, which were evaluated varying the electrical work and the micro calorimeter surrounding temperature. Relationships can be seen between the variables employed in the observation of stability, temperature, potency levels and generated noise.</abstract><cop>Dordrecht</cop><pub>Springer Netherlands</pub><doi>10.1007/s10973-009-0333-8</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1388-6150 |
ispartof | Journal of thermal analysis and calorimetry, 2009-08, Vol.97 (2), p.705-709 |
issn | 1388-6150 1588-2926 1572-8943 |
language | eng |
recordid | cdi_proquest_miscellaneous_1671260406 |
source | Springer Nature |
subjects | Adsorption Analytical Chemistry Calorimetry Chemical and thermal methods Chemistry Chemistry and Materials Science Exact sciences and technology Inorganic Chemistry Measurement Science and Instrumentation Microcalorimeters Noise Noise levels Physical Chemistry Polymer Sciences Stability Thermal analysis |
title | Variation of the noise levels in the baseline of an adsorption microcalorimeter |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T13%3A27%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Variation%20of%20the%20noise%20levels%20in%20the%20baseline%20of%20an%20adsorption%20microcalorimeter&rft.jtitle=Journal%20of%20thermal%20analysis%20and%20calorimetry&rft.au=Garc%C3%ADa-Cuello,%20V.&rft.date=2009-08-01&rft.volume=97&rft.issue=2&rft.spage=705&rft.epage=709&rft.pages=705-709&rft.issn=1388-6150&rft.eissn=1588-2926&rft_id=info:doi/10.1007/s10973-009-0333-8&rft_dat=%3Cproquest_cross%3E1671260406%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c394t-a81e46a72b81dfeafefefa8091ca91e75000b71a7812f71191f2eb03f2c2acb13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1671260406&rft_id=info:pmid/&rfr_iscdi=true |