Loading…

Variation of the noise levels in the baseline of an adsorption microcalorimeter

This work shows the results obtained to determine the noise in the baseline of a specially designed Tian Calvet-Type adsorption microcalorimeter. The results show that noise levels vary from 0.5 to 10 μV, which were evaluated varying the electrical work and the micro calorimeter surrounding temperat...

Full description

Saved in:
Bibliographic Details
Published in:Journal of thermal analysis and calorimetry 2009-08, Vol.97 (2), p.705-709
Main Authors: García-Cuello, V., Moreno-Pirajan, J. C., Giraldo-Gutiérrez, L., Sapag, K., Zgrablich, G.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c394t-a81e46a72b81dfeafefefa8091ca91e75000b71a7812f71191f2eb03f2c2acb13
cites cdi_FETCH-LOGICAL-c394t-a81e46a72b81dfeafefefa8091ca91e75000b71a7812f71191f2eb03f2c2acb13
container_end_page 709
container_issue 2
container_start_page 705
container_title Journal of thermal analysis and calorimetry
container_volume 97
creator García-Cuello, V.
Moreno-Pirajan, J. C.
Giraldo-Gutiérrez, L.
Sapag, K.
Zgrablich, G.
description This work shows the results obtained to determine the noise in the baseline of a specially designed Tian Calvet-Type adsorption microcalorimeter. The results show that noise levels vary from 0.5 to 10 μV, which were evaluated varying the electrical work and the micro calorimeter surrounding temperature. Relationships can be seen between the variables employed in the observation of stability, temperature, potency levels and generated noise.
doi_str_mv 10.1007/s10973-009-0333-8
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1671260406</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1671260406</sourcerecordid><originalsourceid>FETCH-LOGICAL-c394t-a81e46a72b81dfeafefefa8091ca91e75000b71a7812f71191f2eb03f2c2acb13</originalsourceid><addsrcrecordid>eNp9kE1LxDAQhosouOj-AG-9CF6qM-m2SY6y-AXCXtRrmHYnGukma9IV_PdmP_Aoc5ghed6XmbcoLhCuEUDeJAQt6wpAV1DXdaWOigk2SlVCi_Y4z3WeW2zgtJim5DoQCK1ulJ4UizeKjkYXfBlsOX5w6YNLXA78zUMqnd-9dZR4cJ63DPmSlinE9U60cn0MPQ0huhWPHM-LE0tD4umhnxWv93cv88fqefHwNL99rvpaz8aKFPKsJSk6hUvLZDkXKdDYk0aWDQB0EkkqFFYiarSCO6it6AX1HdZnxdXedx3D14bTaFYu9TwM5DlsksFWomhhBm1GcY_mTVOKbM06L0vxxyCYbX5mn5_J-ZltfkZlzeXBnlK-zkbyvUt_QiFANk0DmRN7LuUv_87RfIZN9Pnyf8x_Af5sgFg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1671260406</pqid></control><display><type>article</type><title>Variation of the noise levels in the baseline of an adsorption microcalorimeter</title><source>Springer Nature</source><creator>García-Cuello, V. ; Moreno-Pirajan, J. C. ; Giraldo-Gutiérrez, L. ; Sapag, K. ; Zgrablich, G.</creator><creatorcontrib>García-Cuello, V. ; Moreno-Pirajan, J. C. ; Giraldo-Gutiérrez, L. ; Sapag, K. ; Zgrablich, G.</creatorcontrib><description>This work shows the results obtained to determine the noise in the baseline of a specially designed Tian Calvet-Type adsorption microcalorimeter. The results show that noise levels vary from 0.5 to 10 μV, which were evaluated varying the electrical work and the micro calorimeter surrounding temperature. Relationships can be seen between the variables employed in the observation of stability, temperature, potency levels and generated noise.</description><identifier>ISSN: 1388-6150</identifier><identifier>EISSN: 1588-2926</identifier><identifier>EISSN: 1572-8943</identifier><identifier>DOI: 10.1007/s10973-009-0333-8</identifier><language>eng</language><publisher>Dordrecht: Springer Netherlands</publisher><subject>Adsorption ; Analytical Chemistry ; Calorimetry ; Chemical and thermal methods ; Chemistry ; Chemistry and Materials Science ; Exact sciences and technology ; Inorganic Chemistry ; Measurement Science and Instrumentation ; Microcalorimeters ; Noise ; Noise levels ; Physical Chemistry ; Polymer Sciences ; Stability ; Thermal analysis</subject><ispartof>Journal of thermal analysis and calorimetry, 2009-08, Vol.97 (2), p.705-709</ispartof><rights>Akadémiai Kiadó, Budapest, Hungary 2009</rights><rights>2015 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c394t-a81e46a72b81dfeafefefa8091ca91e75000b71a7812f71191f2eb03f2c2acb13</citedby><cites>FETCH-LOGICAL-c394t-a81e46a72b81dfeafefefa8091ca91e75000b71a7812f71191f2eb03f2c2acb13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=22075550$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>García-Cuello, V.</creatorcontrib><creatorcontrib>Moreno-Pirajan, J. C.</creatorcontrib><creatorcontrib>Giraldo-Gutiérrez, L.</creatorcontrib><creatorcontrib>Sapag, K.</creatorcontrib><creatorcontrib>Zgrablich, G.</creatorcontrib><title>Variation of the noise levels in the baseline of an adsorption microcalorimeter</title><title>Journal of thermal analysis and calorimetry</title><addtitle>J Therm Anal Calorim</addtitle><description>This work shows the results obtained to determine the noise in the baseline of a specially designed Tian Calvet-Type adsorption microcalorimeter. The results show that noise levels vary from 0.5 to 10 μV, which were evaluated varying the electrical work and the micro calorimeter surrounding temperature. Relationships can be seen between the variables employed in the observation of stability, temperature, potency levels and generated noise.</description><subject>Adsorption</subject><subject>Analytical Chemistry</subject><subject>Calorimetry</subject><subject>Chemical and thermal methods</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Exact sciences and technology</subject><subject>Inorganic Chemistry</subject><subject>Measurement Science and Instrumentation</subject><subject>Microcalorimeters</subject><subject>Noise</subject><subject>Noise levels</subject><subject>Physical Chemistry</subject><subject>Polymer Sciences</subject><subject>Stability</subject><subject>Thermal analysis</subject><issn>1388-6150</issn><issn>1588-2926</issn><issn>1572-8943</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2009</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LxDAQhosouOj-AG-9CF6qM-m2SY6y-AXCXtRrmHYnGukma9IV_PdmP_Aoc5ghed6XmbcoLhCuEUDeJAQt6wpAV1DXdaWOigk2SlVCi_Y4z3WeW2zgtJim5DoQCK1ulJ4UizeKjkYXfBlsOX5w6YNLXA78zUMqnd-9dZR4cJ63DPmSlinE9U60cn0MPQ0huhWPHM-LE0tD4umhnxWv93cv88fqefHwNL99rvpaz8aKFPKsJSk6hUvLZDkXKdDYk0aWDQB0EkkqFFYiarSCO6it6AX1HdZnxdXedx3D14bTaFYu9TwM5DlsksFWomhhBm1GcY_mTVOKbM06L0vxxyCYbX5mn5_J-ZltfkZlzeXBnlK-zkbyvUt_QiFANk0DmRN7LuUv_87RfIZN9Pnyf8x_Af5sgFg</recordid><startdate>20090801</startdate><enddate>20090801</enddate><creator>García-Cuello, V.</creator><creator>Moreno-Pirajan, J. C.</creator><creator>Giraldo-Gutiérrez, L.</creator><creator>Sapag, K.</creator><creator>Zgrablich, G.</creator><general>Springer Netherlands</general><general>Springer</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>20090801</creationdate><title>Variation of the noise levels in the baseline of an adsorption microcalorimeter</title><author>García-Cuello, V. ; Moreno-Pirajan, J. C. ; Giraldo-Gutiérrez, L. ; Sapag, K. ; Zgrablich, G.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c394t-a81e46a72b81dfeafefefa8091ca91e75000b71a7812f71191f2eb03f2c2acb13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2009</creationdate><topic>Adsorption</topic><topic>Analytical Chemistry</topic><topic>Calorimetry</topic><topic>Chemical and thermal methods</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Exact sciences and technology</topic><topic>Inorganic Chemistry</topic><topic>Measurement Science and Instrumentation</topic><topic>Microcalorimeters</topic><topic>Noise</topic><topic>Noise levels</topic><topic>Physical Chemistry</topic><topic>Polymer Sciences</topic><topic>Stability</topic><topic>Thermal analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>García-Cuello, V.</creatorcontrib><creatorcontrib>Moreno-Pirajan, J. C.</creatorcontrib><creatorcontrib>Giraldo-Gutiérrez, L.</creatorcontrib><creatorcontrib>Sapag, K.</creatorcontrib><creatorcontrib>Zgrablich, G.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of thermal analysis and calorimetry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>García-Cuello, V.</au><au>Moreno-Pirajan, J. C.</au><au>Giraldo-Gutiérrez, L.</au><au>Sapag, K.</au><au>Zgrablich, G.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Variation of the noise levels in the baseline of an adsorption microcalorimeter</atitle><jtitle>Journal of thermal analysis and calorimetry</jtitle><stitle>J Therm Anal Calorim</stitle><date>2009-08-01</date><risdate>2009</risdate><volume>97</volume><issue>2</issue><spage>705</spage><epage>709</epage><pages>705-709</pages><issn>1388-6150</issn><eissn>1588-2926</eissn><eissn>1572-8943</eissn><abstract>This work shows the results obtained to determine the noise in the baseline of a specially designed Tian Calvet-Type adsorption microcalorimeter. The results show that noise levels vary from 0.5 to 10 μV, which were evaluated varying the electrical work and the micro calorimeter surrounding temperature. Relationships can be seen between the variables employed in the observation of stability, temperature, potency levels and generated noise.</abstract><cop>Dordrecht</cop><pub>Springer Netherlands</pub><doi>10.1007/s10973-009-0333-8</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1388-6150
ispartof Journal of thermal analysis and calorimetry, 2009-08, Vol.97 (2), p.705-709
issn 1388-6150
1588-2926
1572-8943
language eng
recordid cdi_proquest_miscellaneous_1671260406
source Springer Nature
subjects Adsorption
Analytical Chemistry
Calorimetry
Chemical and thermal methods
Chemistry
Chemistry and Materials Science
Exact sciences and technology
Inorganic Chemistry
Measurement Science and Instrumentation
Microcalorimeters
Noise
Noise levels
Physical Chemistry
Polymer Sciences
Stability
Thermal analysis
title Variation of the noise levels in the baseline of an adsorption microcalorimeter
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T13%3A27%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Variation%20of%20the%20noise%20levels%20in%20the%20baseline%20of%20an%20adsorption%20microcalorimeter&rft.jtitle=Journal%20of%20thermal%20analysis%20and%20calorimetry&rft.au=Garc%C3%ADa-Cuello,%20V.&rft.date=2009-08-01&rft.volume=97&rft.issue=2&rft.spage=705&rft.epage=709&rft.pages=705-709&rft.issn=1388-6150&rft.eissn=1588-2926&rft_id=info:doi/10.1007/s10973-009-0333-8&rft_dat=%3Cproquest_cross%3E1671260406%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c394t-a81e46a72b81dfeafefefa8091ca91e75000b71a7812f71191f2eb03f2c2acb13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1671260406&rft_id=info:pmid/&rfr_iscdi=true