Loading…
An experimental investigation of thermal contact conductance of Hastelloy C-276 based on steady-state heat flux method
In this study, measurements of the thermal contact conductance (TCC) at the interfaces of Hastelloy C-276/Hastelloy C-276 and Hastelloy C-276/SS302 test pairs were conducted by a self-developed experimental setup based on the steady-state heat flux method. The reliability of experimental setup and m...
Saved in:
Published in: | International communications in heat and mass transfer 2013-02, Vol.41, p.63-67 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | In this study, measurements of the thermal contact conductance (TCC) at the interfaces of Hastelloy C-276/Hastelloy C-276 and Hastelloy C-276/SS302 test pairs were conducted by a self-developed experimental setup based on the steady-state heat flux method. The reliability of experimental setup and method was validated by the repeated measurement of the thermal contact conductance between Hastelloy C-276 and Hastelloy C-276. In addition, the effects of contact pressure and interfacial temperature on thermal contact conductance were also discussed. This study not only provides a necessary database for the accurate numerical simulation but also lays a foundation for the optimal design of the shrink fitting process of rotor can. |
---|---|
ISSN: | 0735-1933 1879-0178 |
DOI: | 10.1016/j.icheatmasstransfer.2012.11.007 |