Loading…
Radon in Domestic Water Supplies in the UK
In a novel experiment carried out by school children the level of naturally occurring 222Rn has been measured in domestic tap water at 504 locations throughout the UK. Most values were close to 1 Bq.1-1 and none were above the limit suggested by the UK National Radiological Protection Board of 100 B...
Saved in:
Published in: | Radiation protection dosimetry 1993-01, Vol.46 (4), p.285-289 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | In a novel experiment carried out by school children the level of naturally occurring 222Rn has been measured in domestic tap water at 504 locations throughout the UK. Most values were close to 1 Bq.1-1 and none were above the limit suggested by the UK National Radiological Protection Board of 100 Bq.1-1. The values are considerably lower than in many US tap waters and provide a negligible contribution to the level of inhaled radon in room air. |
---|---|
ISSN: | 0144-8420 1742-3406 1742-3406 |
DOI: | 10.1093/oxfordjournals.rpd.a081688 |