Loading…

Mechanical and wear behavior of quenched and tempered alloyed hypereutectic gray cast iron

The effect of tempering temperature (100–600°C) on the hardness and wear resistance of a series of quenched and tempered hypereutectic alloyed gray cast irons has been studied in this work. Hardness was observed decreases with increase in tempering temperature and this trend is influenced by alloyin...

Full description

Saved in:
Bibliographic Details
Published in:Materials in engineering 2011-04, Vol.32 (4), p.2438-2443
Main Authors: Vadiraj, Aravind, Balachandran, G., Kamaraj, M., Kazuya, Ekusa
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The effect of tempering temperature (100–600°C) on the hardness and wear resistance of a series of quenched and tempered hypereutectic alloyed gray cast irons has been studied in this work. Hardness was observed decreases with increase in tempering temperature and this trend is influenced by alloying additions and the volume of graphite flakes. Hardness of alloyed gray irons is also influenced by solid solution strengthening of tempered ferrite and carbide content and their distribution. The wear loss of alloyed cast irons was found to be lowest at a tempering temperature of 100°C and 400°C. The optimum tempering temperature is 400°C with moderate hardness and low wear rate. This has been attributed to strengthening of the matrix at this temperature. Beyond 400°C, the wear rate increases significantly due to carbide coagulation.
ISSN:0261-3069
DOI:10.1016/j.matdes.2010.11.052