Experimental investigation of R227ea applied as working fluid in the ORC power plant with hermetic turbogenerator
Results of experimental investigations of the ORC power plant operating with R227ea as the cycle working fluid are presented. The ORC power plant was fuelled with hot water of the temperature ranging from 66 °C up to 111 °C, at the maximum volume flow of 106 L/min. The ORC research installation was...
Saved in:
Published in: | Applied thermal engineering 2013-07, Vol.56 (1-2), p.126-133 |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Results of experimental investigations of the ORC power plant operating with R227ea as the cycle working fluid are presented. The ORC power plant was fuelled with hot water of the temperature ranging from 66 °C up to 111 °C, at the maximum volume flow of 106 L/min. The ORC research installation was provided with a hermetic turbogenerator of special design to run at 3000 rpm in the nominal operating point. Detailed scheme of the research installation together with the measurement points locations are presented in the paper. The experimental results are supported by relevant calculation results that include an analysis and discussion of the quantities affecting the ORC power plant operation.
•Experimental investigations of the ORC power plant operating with R227ea are presented.•The power plant was fuelled with hot water (from 66 °C up to 111 °C).•The ORC installation was provided with a hermetic turbogenerator. |
---|---|
ISSN: | 1359-4311 |