Loading…
Suppression of parasitic space-charge oscillations in a gyrotron
We study the influence of nonuniform electric and magnetic fields in the helical-beam compression region on the low-frequency parasitic space-charge oscillations for a moderate-power ( 100 kW) 4-mm gyrotron. Suppression of the oscillations is achieved by optimization of both the cathode-unit geometr...
Saved in:
Published in: | Radiophysics and quantum electronics 2006-10, Vol.49 (10), p.793-798 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | We study the influence of nonuniform electric and magnetic fields in the helical-beam compression region on the low-frequency parasitic space-charge oscillations for a moderate-power ( 100 kW) 4-mm gyrotron. Suppression of the oscillations is achieved by optimization of both the cathode-unit geometry in the magnetron-injector gun and the magnetic-field distribution in the region near the cavity input. The obtained data are evidence of possible effective operation of the gyrotron at elevated pitch-factor values α > 1.5 even for emitters with no highest emission uniformity ([delta]j^sub e^ [asymptotically =] 30%).[PUBLICATION ABSTRACT] |
---|---|
ISSN: | 0033-8443 1573-9120 |
DOI: | 10.1007/s11141-006-0114-1 |