Loading…
Reliability and validity of a custom-made instrument including a hand-held dynamometer for measuring trunk muscle strength
Measuring isometric strength is necessary in many areas of health and sport. However, trunk muscles have some particular characteristics that make them difficult to evaluate with simple, inexpensive instruments. To evaluate the reliability and validity of an instrument constructed with a hand-held d...
Saved in:
Published in: | Journal of back and musculoskeletal rehabilitation 2015-01, Vol.28 (2), p.317-326 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c427t-d68ef0dbc32d7a0bb77fcfb8e514e28957cdf38cc3ce0dac8831ffff67feadc53 |
---|---|
cites | |
container_end_page | 326 |
container_issue | 2 |
container_start_page | 317 |
container_title | Journal of back and musculoskeletal rehabilitation |
container_volume | 28 |
creator | Jubany, Júlia Busquets, Albert Marina, Michel Cos, Francesc Angulo-Barroso, Rosa |
description | Measuring isometric strength is necessary in many areas of health and sport. However, trunk muscles have some particular characteristics that make them difficult to evaluate with simple, inexpensive instruments.
To evaluate the reliability and validity of an instrument constructed with a hand-held dynamometer and a metallic structure (HHD+S) for measuring maximum isometric voluntary trunk muscle strength.
Maximum isometric voluntary trunk muscle strength (extension, flexion and lateral flexion) was measured in 20 healthy individuals using the custom-made instrument (HHD+S) and the gold standard Back-Check (BC).
The results showed that the two instruments had high and similar intra-subject reliability. The validity of the HHD+S was demonstrated by the high Pearson coefficient correlation between the two instruments (r ⩾ 0.78).
Given the good trial reliability and the close correlation between the two instruments, we believe that the use of a hand-held dynamometer together with the custom-made metallic structure (HHD+S) allows an evaluation of the maximum isometric voluntary trunk muscle strength to be made, that is very similar in quality, accuracy and reliability to the BC. |
doi_str_mv | 10.3233/bmr-140522 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1680448311</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1669838186</sourcerecordid><originalsourceid>FETCH-LOGICAL-c427t-d68ef0dbc32d7a0bb77fcfb8e514e28957cdf38cc3ce0dac8831ffff67feadc53</originalsourceid><addsrcrecordid>eNqNkUtLAzEUhYMoVqsbf4BkKcJoHvNIl1p8QUUouh4yyU07mszUZCLUX29Kq2vv5p4D3zmbg9AZJVeccX7dOJ_RnBSM7aEjKiqRlZzl-0mTgmeCsmqEjkN4J4SURBSHaMQKMik5nRyh7znYVjatbYc1lp3GX9K2emN6gyVWMQy9y5zUgNsuDD466IYklY267RYJWaZUtgSrsV530vUOBvDY9B47kCH6DZVy3Qd2MSgLOLVAtxiWJ-jASBvgdPfH6O3-7nX6mM1eHp6mN7NM5awaMl0KMEQ3ijNdSdI0VWWUaQQUNAcmJkWltOFCKa6AaKmE4NSkKysDUquCj9HFtnfl-88IYahdGxRYKzvoY6hpKUiepxT9B1pOBBdUlAm93KLK9yF4MPXKt076dU1JvZmlvn2e19tZEny-642NA_2H_u7AfwCY4YvV</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1669838186</pqid></control><display><type>article</type><title>Reliability and validity of a custom-made instrument including a hand-held dynamometer for measuring trunk muscle strength</title><source>EBSCOhost SPORTDiscus with Full Text</source><creator>Jubany, Júlia ; Busquets, Albert ; Marina, Michel ; Cos, Francesc ; Angulo-Barroso, Rosa</creator><creatorcontrib>Jubany, Júlia ; Busquets, Albert ; Marina, Michel ; Cos, Francesc ; Angulo-Barroso, Rosa</creatorcontrib><description>Measuring isometric strength is necessary in many areas of health and sport. However, trunk muscles have some particular characteristics that make them difficult to evaluate with simple, inexpensive instruments.
To evaluate the reliability and validity of an instrument constructed with a hand-held dynamometer and a metallic structure (HHD+S) for measuring maximum isometric voluntary trunk muscle strength.
Maximum isometric voluntary trunk muscle strength (extension, flexion and lateral flexion) was measured in 20 healthy individuals using the custom-made instrument (HHD+S) and the gold standard Back-Check (BC).
The results showed that the two instruments had high and similar intra-subject reliability. The validity of the HHD+S was demonstrated by the high Pearson coefficient correlation between the two instruments (r ⩾ 0.78).
Given the good trial reliability and the close correlation between the two instruments, we believe that the use of a hand-held dynamometer together with the custom-made metallic structure (HHD+S) allows an evaluation of the maximum isometric voluntary trunk muscle strength to be made, that is very similar in quality, accuracy and reliability to the BC.</description><identifier>ISSN: 1053-8127</identifier><identifier>EISSN: 1878-6324</identifier><identifier>DOI: 10.3233/bmr-140522</identifier><identifier>PMID: 25096319</identifier><language>eng</language><publisher>Netherlands</publisher><subject>Adolescent ; Adult ; Back ; Female ; Humans ; Isometric Contraction - physiology ; Male ; Muscle Contraction - physiology ; Muscle Strength - physiology ; Muscle Strength Dynamometer ; Muscle, Skeletal - physiology ; Range of Motion, Articular ; Reproducibility of Results ; Torso - physiology ; Young Adult</subject><ispartof>Journal of back and musculoskeletal rehabilitation, 2015-01, Vol.28 (2), p.317-326</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c427t-d68ef0dbc32d7a0bb77fcfb8e514e28957cdf38cc3ce0dac8831ffff67feadc53</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25096319$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Jubany, Júlia</creatorcontrib><creatorcontrib>Busquets, Albert</creatorcontrib><creatorcontrib>Marina, Michel</creatorcontrib><creatorcontrib>Cos, Francesc</creatorcontrib><creatorcontrib>Angulo-Barroso, Rosa</creatorcontrib><title>Reliability and validity of a custom-made instrument including a hand-held dynamometer for measuring trunk muscle strength</title><title>Journal of back and musculoskeletal rehabilitation</title><addtitle>J Back Musculoskelet Rehabil</addtitle><description>Measuring isometric strength is necessary in many areas of health and sport. However, trunk muscles have some particular characteristics that make them difficult to evaluate with simple, inexpensive instruments.
To evaluate the reliability and validity of an instrument constructed with a hand-held dynamometer and a metallic structure (HHD+S) for measuring maximum isometric voluntary trunk muscle strength.
Maximum isometric voluntary trunk muscle strength (extension, flexion and lateral flexion) was measured in 20 healthy individuals using the custom-made instrument (HHD+S) and the gold standard Back-Check (BC).
The results showed that the two instruments had high and similar intra-subject reliability. The validity of the HHD+S was demonstrated by the high Pearson coefficient correlation between the two instruments (r ⩾ 0.78).
Given the good trial reliability and the close correlation between the two instruments, we believe that the use of a hand-held dynamometer together with the custom-made metallic structure (HHD+S) allows an evaluation of the maximum isometric voluntary trunk muscle strength to be made, that is very similar in quality, accuracy and reliability to the BC.</description><subject>Adolescent</subject><subject>Adult</subject><subject>Back</subject><subject>Female</subject><subject>Humans</subject><subject>Isometric Contraction - physiology</subject><subject>Male</subject><subject>Muscle Contraction - physiology</subject><subject>Muscle Strength - physiology</subject><subject>Muscle Strength Dynamometer</subject><subject>Muscle, Skeletal - physiology</subject><subject>Range of Motion, Articular</subject><subject>Reproducibility of Results</subject><subject>Torso - physiology</subject><subject>Young Adult</subject><issn>1053-8127</issn><issn>1878-6324</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNqNkUtLAzEUhYMoVqsbf4BkKcJoHvNIl1p8QUUouh4yyU07mszUZCLUX29Kq2vv5p4D3zmbg9AZJVeccX7dOJ_RnBSM7aEjKiqRlZzl-0mTgmeCsmqEjkN4J4SURBSHaMQKMik5nRyh7znYVjatbYc1lp3GX9K2emN6gyVWMQy9y5zUgNsuDD466IYklY267RYJWaZUtgSrsV530vUOBvDY9B47kCH6DZVy3Qd2MSgLOLVAtxiWJ-jASBvgdPfH6O3-7nX6mM1eHp6mN7NM5awaMl0KMEQ3ijNdSdI0VWWUaQQUNAcmJkWltOFCKa6AaKmE4NSkKysDUquCj9HFtnfl-88IYahdGxRYKzvoY6hpKUiepxT9B1pOBBdUlAm93KLK9yF4MPXKt076dU1JvZmlvn2e19tZEny-642NA_2H_u7AfwCY4YvV</recordid><startdate>20150101</startdate><enddate>20150101</enddate><creator>Jubany, Júlia</creator><creator>Busquets, Albert</creator><creator>Marina, Michel</creator><creator>Cos, Francesc</creator><creator>Angulo-Barroso, Rosa</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7T2</scope><scope>7U2</scope><scope>C1K</scope></search><sort><creationdate>20150101</creationdate><title>Reliability and validity of a custom-made instrument including a hand-held dynamometer for measuring trunk muscle strength</title><author>Jubany, Júlia ; Busquets, Albert ; Marina, Michel ; Cos, Francesc ; Angulo-Barroso, Rosa</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c427t-d68ef0dbc32d7a0bb77fcfb8e514e28957cdf38cc3ce0dac8831ffff67feadc53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Adolescent</topic><topic>Adult</topic><topic>Back</topic><topic>Female</topic><topic>Humans</topic><topic>Isometric Contraction - physiology</topic><topic>Male</topic><topic>Muscle Contraction - physiology</topic><topic>Muscle Strength - physiology</topic><topic>Muscle Strength Dynamometer</topic><topic>Muscle, Skeletal - physiology</topic><topic>Range of Motion, Articular</topic><topic>Reproducibility of Results</topic><topic>Torso - physiology</topic><topic>Young Adult</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jubany, Júlia</creatorcontrib><creatorcontrib>Busquets, Albert</creatorcontrib><creatorcontrib>Marina, Michel</creatorcontrib><creatorcontrib>Cos, Francesc</creatorcontrib><creatorcontrib>Angulo-Barroso, Rosa</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Health and Safety Science Abstracts (Full archive)</collection><collection>Safety Science and Risk</collection><collection>Environmental Sciences and Pollution Management</collection><jtitle>Journal of back and musculoskeletal rehabilitation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jubany, Júlia</au><au>Busquets, Albert</au><au>Marina, Michel</au><au>Cos, Francesc</au><au>Angulo-Barroso, Rosa</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reliability and validity of a custom-made instrument including a hand-held dynamometer for measuring trunk muscle strength</atitle><jtitle>Journal of back and musculoskeletal rehabilitation</jtitle><addtitle>J Back Musculoskelet Rehabil</addtitle><date>2015-01-01</date><risdate>2015</risdate><volume>28</volume><issue>2</issue><spage>317</spage><epage>326</epage><pages>317-326</pages><issn>1053-8127</issn><eissn>1878-6324</eissn><abstract>Measuring isometric strength is necessary in many areas of health and sport. However, trunk muscles have some particular characteristics that make them difficult to evaluate with simple, inexpensive instruments.
To evaluate the reliability and validity of an instrument constructed with a hand-held dynamometer and a metallic structure (HHD+S) for measuring maximum isometric voluntary trunk muscle strength.
Maximum isometric voluntary trunk muscle strength (extension, flexion and lateral flexion) was measured in 20 healthy individuals using the custom-made instrument (HHD+S) and the gold standard Back-Check (BC).
The results showed that the two instruments had high and similar intra-subject reliability. The validity of the HHD+S was demonstrated by the high Pearson coefficient correlation between the two instruments (r ⩾ 0.78).
Given the good trial reliability and the close correlation between the two instruments, we believe that the use of a hand-held dynamometer together with the custom-made metallic structure (HHD+S) allows an evaluation of the maximum isometric voluntary trunk muscle strength to be made, that is very similar in quality, accuracy and reliability to the BC.</abstract><cop>Netherlands</cop><pmid>25096319</pmid><doi>10.3233/bmr-140522</doi><tpages>10</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1053-8127 |
ispartof | Journal of back and musculoskeletal rehabilitation, 2015-01, Vol.28 (2), p.317-326 |
issn | 1053-8127 1878-6324 |
language | eng |
recordid | cdi_proquest_miscellaneous_1680448311 |
source | EBSCOhost SPORTDiscus with Full Text |
subjects | Adolescent Adult Back Female Humans Isometric Contraction - physiology Male Muscle Contraction - physiology Muscle Strength - physiology Muscle Strength Dynamometer Muscle, Skeletal - physiology Range of Motion, Articular Reproducibility of Results Torso - physiology Young Adult |
title | Reliability and validity of a custom-made instrument including a hand-held dynamometer for measuring trunk muscle strength |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T02%3A07%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reliability%20and%20validity%20of%20a%20custom-made%20instrument%20including%20a%20hand-held%20dynamometer%20for%20measuring%20trunk%20muscle%20strength&rft.jtitle=Journal%20of%20back%20and%20musculoskeletal%20rehabilitation&rft.au=Jubany,%20J%C3%BAlia&rft.date=2015-01-01&rft.volume=28&rft.issue=2&rft.spage=317&rft.epage=326&rft.pages=317-326&rft.issn=1053-8127&rft.eissn=1878-6324&rft_id=info:doi/10.3233/bmr-140522&rft_dat=%3Cproquest_cross%3E1669838186%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c427t-d68ef0dbc32d7a0bb77fcfb8e514e28957cdf38cc3ce0dac8831ffff67feadc53%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1669838186&rft_id=info:pmid/25096319&rfr_iscdi=true |