Loading…

On the performance of label-free biosensors based on vertical one-dimensional photonic crystal resonant cavities

In this work three Fabry-Perot (FP) resonant cavities based on vertical silicon/air one-dimensional photonic crystals (1DPhCs) featuring different architectures and fluidic functionalities are designed, and the role of key design parameters on their ideal biosensing performance, i.e. surface sensiti...

Full description

Saved in:
Bibliographic Details
Published in:Optics express 2015-04, Vol.23 (7), p.9192-9201
Main Authors: Surdo, Salvatore, Barillaro, Giuseppe
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c329t-d6dd928f576f7471b10d229f221ad6cf79113538c33e46a08d35e4221f1c8e6e3
cites cdi_FETCH-LOGICAL-c329t-d6dd928f576f7471b10d229f221ad6cf79113538c33e46a08d35e4221f1c8e6e3
container_end_page 9201
container_issue 7
container_start_page 9192
container_title Optics express
container_volume 23
creator Surdo, Salvatore
Barillaro, Giuseppe
description In this work three Fabry-Perot (FP) resonant cavities based on vertical silicon/air one-dimensional photonic crystals (1DPhCs) featuring different architectures and fluidic functionalities are designed, and the role of key design parameters on their ideal biosensing performance, i.e. surface sensitivity, limit of detection, range of linearity, is investigated. Numerical calculations of the transmission spectra of the 1DPhC FP resonant cavities using the Transfer Matrix Method (TMM), versus thickness of a biolayer simulating biomolecules (e.g. proteins) adsorbed on the 1DPhC FP cavity surfaces, show that biosensors with surface sensitivity up to 300 pm/nm, limit of detection down to 0.07 nm, and high linearity over the range 0-50 nm of biolayer thickness can be achieved.
doi_str_mv 10.1364/OE.23.009192
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1680956362</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1680956362</sourcerecordid><originalsourceid>FETCH-LOGICAL-c329t-d6dd928f576f7471b10d229f221ad6cf79113538c33e46a08d35e4221f1c8e6e3</originalsourceid><addsrcrecordid>eNpNkL1PwzAUxC0EoqWwMSOPDKT4I3HiEVXlQ6qUBWbLsZ9VoyQOdlqp_z1BLYjp3bv76YZD6JaSJeUif6zXS8aXhEgq2RmaUyLzLCdVef5Pz9BVSp-E0LyU5SWasUKKqiz4HA11j8ct4AGiC7HTvQEcHG51A23mIgBufEjQpxATbnQCi0OP9xBHb3Q7acis76bch376h20YQ-8NNvGQxsmIkKagH7HRez96SNfowuk2wc3pLtDH8_p99Zpt6pe31dMmM5zJMbPCWskqV5TClXlJG0osY9IxRrUVxpWSUl7wynAOudCksryAfEodNRUI4At0f-wdYvjaQRpV55OBttU9hF1SVFREFoILNqEPR9TEkFIEp4boOx0PihL1s7Gq14pxddx4wu9OzbumA_sH_47KvwGlJ3gn</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1680956362</pqid></control><display><type>article</type><title>On the performance of label-free biosensors based on vertical one-dimensional photonic crystal resonant cavities</title><source>Free E-Journal (出版社公開部分のみ)</source><creator>Surdo, Salvatore ; Barillaro, Giuseppe</creator><creatorcontrib>Surdo, Salvatore ; Barillaro, Giuseppe</creatorcontrib><description>In this work three Fabry-Perot (FP) resonant cavities based on vertical silicon/air one-dimensional photonic crystals (1DPhCs) featuring different architectures and fluidic functionalities are designed, and the role of key design parameters on their ideal biosensing performance, i.e. surface sensitivity, limit of detection, range of linearity, is investigated. Numerical calculations of the transmission spectra of the 1DPhC FP resonant cavities using the Transfer Matrix Method (TMM), versus thickness of a biolayer simulating biomolecules (e.g. proteins) adsorbed on the 1DPhC FP cavity surfaces, show that biosensors with surface sensitivity up to 300 pm/nm, limit of detection down to 0.07 nm, and high linearity over the range 0-50 nm of biolayer thickness can be achieved.</description><identifier>ISSN: 1094-4087</identifier><identifier>EISSN: 1094-4087</identifier><identifier>DOI: 10.1364/OE.23.009192</identifier><identifier>PMID: 25968753</identifier><language>eng</language><publisher>United States</publisher><ispartof>Optics express, 2015-04, Vol.23 (7), p.9192-9201</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c329t-d6dd928f576f7471b10d229f221ad6cf79113538c33e46a08d35e4221f1c8e6e3</citedby><cites>FETCH-LOGICAL-c329t-d6dd928f576f7471b10d229f221ad6cf79113538c33e46a08d35e4221f1c8e6e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25968753$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Surdo, Salvatore</creatorcontrib><creatorcontrib>Barillaro, Giuseppe</creatorcontrib><title>On the performance of label-free biosensors based on vertical one-dimensional photonic crystal resonant cavities</title><title>Optics express</title><addtitle>Opt Express</addtitle><description>In this work three Fabry-Perot (FP) resonant cavities based on vertical silicon/air one-dimensional photonic crystals (1DPhCs) featuring different architectures and fluidic functionalities are designed, and the role of key design parameters on their ideal biosensing performance, i.e. surface sensitivity, limit of detection, range of linearity, is investigated. Numerical calculations of the transmission spectra of the 1DPhC FP resonant cavities using the Transfer Matrix Method (TMM), versus thickness of a biolayer simulating biomolecules (e.g. proteins) adsorbed on the 1DPhC FP cavity surfaces, show that biosensors with surface sensitivity up to 300 pm/nm, limit of detection down to 0.07 nm, and high linearity over the range 0-50 nm of biolayer thickness can be achieved.</description><issn>1094-4087</issn><issn>1094-4087</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNpNkL1PwzAUxC0EoqWwMSOPDKT4I3HiEVXlQ6qUBWbLsZ9VoyQOdlqp_z1BLYjp3bv76YZD6JaSJeUif6zXS8aXhEgq2RmaUyLzLCdVef5Pz9BVSp-E0LyU5SWasUKKqiz4HA11j8ct4AGiC7HTvQEcHG51A23mIgBufEjQpxATbnQCi0OP9xBHb3Q7acis76bch376h20YQ-8NNvGQxsmIkKagH7HRez96SNfowuk2wc3pLtDH8_p99Zpt6pe31dMmM5zJMbPCWskqV5TClXlJG0osY9IxRrUVxpWSUl7wynAOudCksryAfEodNRUI4At0f-wdYvjaQRpV55OBttU9hF1SVFREFoILNqEPR9TEkFIEp4boOx0PihL1s7Gq14pxddx4wu9OzbumA_sH_47KvwGlJ3gn</recordid><startdate>20150406</startdate><enddate>20150406</enddate><creator>Surdo, Salvatore</creator><creator>Barillaro, Giuseppe</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20150406</creationdate><title>On the performance of label-free biosensors based on vertical one-dimensional photonic crystal resonant cavities</title><author>Surdo, Salvatore ; Barillaro, Giuseppe</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c329t-d6dd928f576f7471b10d229f221ad6cf79113538c33e46a08d35e4221f1c8e6e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Surdo, Salvatore</creatorcontrib><creatorcontrib>Barillaro, Giuseppe</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Surdo, Salvatore</au><au>Barillaro, Giuseppe</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>On the performance of label-free biosensors based on vertical one-dimensional photonic crystal resonant cavities</atitle><jtitle>Optics express</jtitle><addtitle>Opt Express</addtitle><date>2015-04-06</date><risdate>2015</risdate><volume>23</volume><issue>7</issue><spage>9192</spage><epage>9201</epage><pages>9192-9201</pages><issn>1094-4087</issn><eissn>1094-4087</eissn><abstract>In this work three Fabry-Perot (FP) resonant cavities based on vertical silicon/air one-dimensional photonic crystals (1DPhCs) featuring different architectures and fluidic functionalities are designed, and the role of key design parameters on their ideal biosensing performance, i.e. surface sensitivity, limit of detection, range of linearity, is investigated. Numerical calculations of the transmission spectra of the 1DPhC FP resonant cavities using the Transfer Matrix Method (TMM), versus thickness of a biolayer simulating biomolecules (e.g. proteins) adsorbed on the 1DPhC FP cavity surfaces, show that biosensors with surface sensitivity up to 300 pm/nm, limit of detection down to 0.07 nm, and high linearity over the range 0-50 nm of biolayer thickness can be achieved.</abstract><cop>United States</cop><pmid>25968753</pmid><doi>10.1364/OE.23.009192</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1094-4087
ispartof Optics express, 2015-04, Vol.23 (7), p.9192-9201
issn 1094-4087
1094-4087
language eng
recordid cdi_proquest_miscellaneous_1680956362
source Free E-Journal (出版社公開部分のみ)
title On the performance of label-free biosensors based on vertical one-dimensional photonic crystal resonant cavities
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T06%3A02%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=On%20the%20performance%20of%20label-free%20biosensors%20based%20on%20vertical%20one-dimensional%20photonic%20crystal%20resonant%20cavities&rft.jtitle=Optics%20express&rft.au=Surdo,%20Salvatore&rft.date=2015-04-06&rft.volume=23&rft.issue=7&rft.spage=9192&rft.epage=9201&rft.pages=9192-9201&rft.issn=1094-4087&rft.eissn=1094-4087&rft_id=info:doi/10.1364/OE.23.009192&rft_dat=%3Cproquest_cross%3E1680956362%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c329t-d6dd928f576f7471b10d229f221ad6cf79113538c33e46a08d35e4221f1c8e6e3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1680956362&rft_id=info:pmid/25968753&rfr_iscdi=true