Loading…

Microfiltration: Effect of channel diameter on limiting flux and serum protein removal

Our objective was to determine the limiting flux and serum protein (SP) removal at 8, 9 and 10% true protein (TP) in the retentate recirculation loop using 0.1-µm ceramic graded permeability (GP) microfiltration (MF) membranes with 3mm channel diameters (CD). An additional objective was to compare t...

Full description

Saved in:
Bibliographic Details
Published in:Journal of dairy science 2015-06, Vol.98 (6), p.3599-3612
Main Authors: Hurt, E E, Adams, M C, Barbano, D M
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Our objective was to determine the limiting flux and serum protein (SP) removal at 8, 9 and 10% true protein (TP) in the retentate recirculation loop using 0.1-µm ceramic graded permeability (GP) microfiltration (MF) membranes with 3mm channel diameters (CD). An additional objective was to compare the limiting flux and SP removal between 0.1-µm ceramic GP membranes with 3mm CD and previous research using 4-mm CD membranes. The MF system was operated at 50°C, using a diluted milk protein concentrate with 85% protein on a total solids basis (MPC85) as the MF feed. The limiting flux for the MF of diluted MPC85 was determined at 8, 9, and 10% TP concentration in the recirculation loop. The experiment using the 3-mm CD membranes was replicated 3 times for a total of 9 runs. On the morning of each run MPC85 was diluted with reverse osmosis water to a MF feed TP concentration of 5.4%. In all runs the starting flux was 55 kg/m2 per hour, the flux was then increased in steps until the limiting flux was reached. For the 3-mm CD membranes, the limiting flux was 128±0.3, 109±4, and 97±0.5 kg/m2 per hour at recirculation loop TP concentrations of 8.1±0.07, 9.2±0.04, and 10.2±0.03%, respectively. For the 3-mm CD membranes, increasing the flux from the starting to the limiting flux decreased the SP removal factor from 0.72±0.02 to 0.67±0.01; however, no difference in SP removal factor among the target recirculation loop TP concentrations was detected. The limiting flux at each recirculation loop target TP concentration was lower for the 3- compared with the 4-mm CD membranes. The differences in limiting fluxes between the 3- and 4-mm CD membranes were explained in part by the difference in cross-flow velocity (5.5±0.03 and 7.0±0.03 m/s for the 3- and 4-mm CD membranes, respectively). The SP removal factor was also lower for the 3- compared with the 4-mm CD membranes, indicating that more membrane fouling may have occurred in the 3- versus 4-mm CD membranes.
ISSN:0022-0302
1525-3198
DOI:10.3168/jds.2014-9225