Loading…
Transient Behavior of Negative Hydrogen Ion Extraction from Plasma
For plasma source, the extraction of negative ions is quite different from that of positive ions. To understand the effect of extraction field on plasma, the time-dependent behavior of negative hydrogen ion extraction from a negative ion source has been studied by particle-in-cell simulation in the...
Saved in:
Published in: | Plasma science & technology 2013-09, Vol.15 (9), p.945-949 |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c304t-57fbbc926a21f62b0dcfc5a9672ff8df0bbb3cd4aebb62c07ccb2581c02a1863 |
---|---|
cites | cdi_FETCH-LOGICAL-c304t-57fbbc926a21f62b0dcfc5a9672ff8df0bbb3cd4aebb62c07ccb2581c02a1863 |
container_end_page | 949 |
container_issue | 9 |
container_start_page | 945 |
container_title | Plasma science & technology |
container_volume | 15 |
creator | 蓝朝晖 彭宇飞 杨振 龙继东 |
description | For plasma source, the extraction of negative ions is quite different from that of positive ions. To understand the effect of extraction field on plasma, the time-dependent behavior of negative hydrogen ion extraction from a negative ion source has been studied by particle-in-cell simulation in the collisionless limit. The simulations have shown that, due to the difference in dynamics between electrons and ions, the imbalance of the numbers of charged particles occurs in the source, results in the broadening of plasma sheath and the great increase of plasma potential. The resultant high sheath field and the ambipolar electric field in plasma make the negatively charged particles congregate inside the sheath and move toward the extraction outlet. The emission area of negative ions is much smaller than that of the extraction aperture, which is in sharp contrast to the case of positive ion extraction. |
doi_str_mv | 10.1088/1009-0630/15/9/21 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1685810645</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cqvip_id>47064268</cqvip_id><sourcerecordid>1685810645</sourcerecordid><originalsourceid>FETCH-LOGICAL-c304t-57fbbc926a21f62b0dcfc5a9672ff8df0bbb3cd4aebb62c07ccb2581c02a1863</originalsourceid><addsrcrecordid>eNo9kLFOwzAURT2ARCl8AFvYWEKencRxRloVWqkChu6W7dipUWK3dqjo35OqVad39XTOHS5CTxheMTCWYYA6BZpDhsuszgi-QZPr7w7dx_gDUBY1yydotgnCRavdkMz0VhysD4k3yaduxWAPOlkem-Bb7ZKVd8nibwhCDXaMJvg--e5E7MUDujWii_rxcqdo877YzJfp-utjNX9bpyqHYkjLykipakIFwYYSCY0yqhQ1rYgxrDEgpcxVUwgtJSUKKqUkKRlWQARmNJ-il3PtLvj9r44D721UuuuE0_43ckzZSAMtyhHFZ1QFH2PQhu-C7UU4cgz8NBE_zcFPc3Bc8poTPDrPF2frXbu3rr1KRTW2EsryfxmTZx0</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1685810645</pqid></control><display><type>article</type><title>Transient Behavior of Negative Hydrogen Ion Extraction from Plasma</title><source>Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)</source><creator>蓝朝晖 彭宇飞 杨振 龙继东</creator><creatorcontrib>蓝朝晖 彭宇飞 杨振 龙继东</creatorcontrib><description>For plasma source, the extraction of negative ions is quite different from that of positive ions. To understand the effect of extraction field on plasma, the time-dependent behavior of negative hydrogen ion extraction from a negative ion source has been studied by particle-in-cell simulation in the collisionless limit. The simulations have shown that, due to the difference in dynamics between electrons and ions, the imbalance of the numbers of charged particles occurs in the source, results in the broadening of plasma sheath and the great increase of plasma potential. The resultant high sheath field and the ambipolar electric field in plasma make the negatively charged particles congregate inside the sheath and move toward the extraction outlet. The emission area of negative ions is much smaller than that of the extraction aperture, which is in sharp contrast to the case of positive ion extraction.</description><identifier>ISSN: 1009-0630</identifier><identifier>DOI: 10.1088/1009-0630/15/9/21</identifier><language>eng</language><subject>Charged particles ; Extraction ; Ion extraction ; Negative ions ; Outlets ; Particle in cell technique ; Plasma potentials ; Sheaths ; Simulation ; 提取 ; 暂态 ; 等离子体电位 ; 等离子体鞘层 ; 胞中粒子模拟 ; 血浆 ; 行为 ; 负氢离子</subject><ispartof>Plasma science & technology, 2013-09, Vol.15 (9), p.945-949</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c304t-57fbbc926a21f62b0dcfc5a9672ff8df0bbb3cd4aebb62c07ccb2581c02a1863</citedby><cites>FETCH-LOGICAL-c304t-57fbbc926a21f62b0dcfc5a9672ff8df0bbb3cd4aebb62c07ccb2581c02a1863</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://image.cqvip.com/vip1000/qk/84262X/84262X.jpg</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids></links><search><creatorcontrib>蓝朝晖 彭宇飞 杨振 龙继东</creatorcontrib><title>Transient Behavior of Negative Hydrogen Ion Extraction from Plasma</title><title>Plasma science & technology</title><addtitle>Plasma Science & Technology</addtitle><description>For plasma source, the extraction of negative ions is quite different from that of positive ions. To understand the effect of extraction field on plasma, the time-dependent behavior of negative hydrogen ion extraction from a negative ion source has been studied by particle-in-cell simulation in the collisionless limit. The simulations have shown that, due to the difference in dynamics between electrons and ions, the imbalance of the numbers of charged particles occurs in the source, results in the broadening of plasma sheath and the great increase of plasma potential. The resultant high sheath field and the ambipolar electric field in plasma make the negatively charged particles congregate inside the sheath and move toward the extraction outlet. The emission area of negative ions is much smaller than that of the extraction aperture, which is in sharp contrast to the case of positive ion extraction.</description><subject>Charged particles</subject><subject>Extraction</subject><subject>Ion extraction</subject><subject>Negative ions</subject><subject>Outlets</subject><subject>Particle in cell technique</subject><subject>Plasma potentials</subject><subject>Sheaths</subject><subject>Simulation</subject><subject>提取</subject><subject>暂态</subject><subject>等离子体电位</subject><subject>等离子体鞘层</subject><subject>胞中粒子模拟</subject><subject>血浆</subject><subject>行为</subject><subject>负氢离子</subject><issn>1009-0630</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNo9kLFOwzAURT2ARCl8AFvYWEKencRxRloVWqkChu6W7dipUWK3dqjo35OqVad39XTOHS5CTxheMTCWYYA6BZpDhsuszgi-QZPr7w7dx_gDUBY1yydotgnCRavdkMz0VhysD4k3yaduxWAPOlkem-Bb7ZKVd8nibwhCDXaMJvg--e5E7MUDujWii_rxcqdo877YzJfp-utjNX9bpyqHYkjLykipakIFwYYSCY0yqhQ1rYgxrDEgpcxVUwgtJSUKKqUkKRlWQARmNJ-il3PtLvj9r44D721UuuuE0_43ckzZSAMtyhHFZ1QFH2PQhu-C7UU4cgz8NBE_zcFPc3Bc8poTPDrPF2frXbu3rr1KRTW2EsryfxmTZx0</recordid><startdate>20130901</startdate><enddate>20130901</enddate><creator>蓝朝晖 彭宇飞 杨振 龙继东</creator><scope>2RA</scope><scope>92L</scope><scope>CQIGP</scope><scope>W92</scope><scope>~WA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20130901</creationdate><title>Transient Behavior of Negative Hydrogen Ion Extraction from Plasma</title><author>蓝朝晖 彭宇飞 杨振 龙继东</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c304t-57fbbc926a21f62b0dcfc5a9672ff8df0bbb3cd4aebb62c07ccb2581c02a1863</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Charged particles</topic><topic>Extraction</topic><topic>Ion extraction</topic><topic>Negative ions</topic><topic>Outlets</topic><topic>Particle in cell technique</topic><topic>Plasma potentials</topic><topic>Sheaths</topic><topic>Simulation</topic><topic>提取</topic><topic>暂态</topic><topic>等离子体电位</topic><topic>等离子体鞘层</topic><topic>胞中粒子模拟</topic><topic>血浆</topic><topic>行为</topic><topic>负氢离子</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>蓝朝晖 彭宇飞 杨振 龙继东</creatorcontrib><collection>中文科技期刊数据库</collection><collection>中文科技期刊数据库-CALIS站点</collection><collection>中文科技期刊数据库-7.0平台</collection><collection>中文科技期刊数据库-工程技术</collection><collection>中文科技期刊数据库- 镜像站点</collection><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Plasma science & technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>蓝朝晖 彭宇飞 杨振 龙继东</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Transient Behavior of Negative Hydrogen Ion Extraction from Plasma</atitle><jtitle>Plasma science & technology</jtitle><addtitle>Plasma Science & Technology</addtitle><date>2013-09-01</date><risdate>2013</risdate><volume>15</volume><issue>9</issue><spage>945</spage><epage>949</epage><pages>945-949</pages><issn>1009-0630</issn><abstract>For plasma source, the extraction of negative ions is quite different from that of positive ions. To understand the effect of extraction field on plasma, the time-dependent behavior of negative hydrogen ion extraction from a negative ion source has been studied by particle-in-cell simulation in the collisionless limit. The simulations have shown that, due to the difference in dynamics between electrons and ions, the imbalance of the numbers of charged particles occurs in the source, results in the broadening of plasma sheath and the great increase of plasma potential. The resultant high sheath field and the ambipolar electric field in plasma make the negatively charged particles congregate inside the sheath and move toward the extraction outlet. The emission area of negative ions is much smaller than that of the extraction aperture, which is in sharp contrast to the case of positive ion extraction.</abstract><doi>10.1088/1009-0630/15/9/21</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1009-0630 |
ispartof | Plasma science & technology, 2013-09, Vol.15 (9), p.945-949 |
issn | 1009-0630 |
language | eng |
recordid | cdi_proquest_miscellaneous_1685810645 |
source | Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List) |
subjects | Charged particles Extraction Ion extraction Negative ions Outlets Particle in cell technique Plasma potentials Sheaths Simulation 提取 暂态 等离子体电位 等离子体鞘层 胞中粒子模拟 血浆 行为 负氢离子 |
title | Transient Behavior of Negative Hydrogen Ion Extraction from Plasma |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T16%3A52%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Transient%20Behavior%20of%20Negative%20Hydrogen%20Ion%20Extraction%20from%20Plasma&rft.jtitle=Plasma%20science%20&%20technology&rft.au=%E8%93%9D%E6%9C%9D%E6%99%96%20%E5%BD%AD%E5%AE%87%E9%A3%9E%20%E6%9D%A8%E6%8C%AF%20%E9%BE%99%E7%BB%A7%E4%B8%9C&rft.date=2013-09-01&rft.volume=15&rft.issue=9&rft.spage=945&rft.epage=949&rft.pages=945-949&rft.issn=1009-0630&rft_id=info:doi/10.1088/1009-0630/15/9/21&rft_dat=%3Cproquest_cross%3E1685810645%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c304t-57fbbc926a21f62b0dcfc5a9672ff8df0bbb3cd4aebb62c07ccb2581c02a1863%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1685810645&rft_id=info:pmid/&rft_cqvip_id=47064268&rfr_iscdi=true |