Loading…
Calibration-Free Ionophore-Based Ion-Selective Electrodes With a Co(II)/Co(III) Redox Couple-Based Solid Contact
A high electrode-to-electrode reproducibility of the emf response of solid contact ion-selective electrodes (SC-ISEs) requires a precise control of the phase boundary potential between the ion-selective membrane (ISM) and the underlying electron conductor. To achieve this, we introduced previously i...
Saved in:
Published in: | Analytical chemistry (Washington) 2014-09, Vol.86 (17), p.8687-8692 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-a376t-768588348b9b4832bd84b3fc99f776a2aec5ca4b011c1b82963f87f86f72277b3 |
---|---|
cites | cdi_FETCH-LOGICAL-a376t-768588348b9b4832bd84b3fc99f776a2aec5ca4b011c1b82963f87f86f72277b3 |
container_end_page | 8692 |
container_issue | 17 |
container_start_page | 8687 |
container_title | Analytical chemistry (Washington) |
container_volume | 86 |
creator | Zou, Xu U. Zhen, Xue V. Cheong, Jia H. Bühlmann, Philippe |
description | A high electrode-to-electrode reproducibility of the emf response of solid contact ion-selective electrodes (SC-ISEs) requires a precise control of the phase boundary potential between the ion-selective membrane (ISM) and the underlying electron conductor. To achieve this, we introduced previously ionophore-free ion exchanger membranes doped with a well controlled ratio of oxidized and reduced species of a redox couple as redox buffer and used them to make SC-ISEs that exhibited highly reproducible electrode-to-electrode potentials. Unfortunately, ionophores were found to promote the loss of insufficiently lipophilic species from the ionophore-doped ISMs into aqueous samples. Here we report on an improved redox buffer platform based on equimolar amounts of the much less hydrophilic Co(III) and Co(II) complexes of 4,4′-dinonyl-2,2′-bipyridyl, which makes it possible to extend the redox buffer approach to ionophore-based ISEs. For example, K+-selective electrodes based on the ionophore valinomycin exhibit electrode-to-electrode standard deviations as low as 0.7 mV after exposure of freshly prepared electrodes for 1 h to aqueous solutions. Exposure of freshly prepared ISE membranes to humidity prior to their first contact to electrolyte solution minimizes the initial (reproducible) emf drift. This redox buffer has also been successfully applied to sodium, potassium, calcium, hydrogen, and carbonate ion-selective electrodes, which all exhibit the high selectivity over interfering ions as expected for ionophore-doped ISE membranes. |
doi_str_mv | 10.1021/ac501625z |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1692381150</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3428050331</sourcerecordid><originalsourceid>FETCH-LOGICAL-a376t-768588348b9b4832bd84b3fc99f776a2aec5ca4b011c1b82963f87f86f72277b3</originalsourceid><addsrcrecordid>eNqF0VtL7DAQB_AgR3S9PPgFpCDC7kM1kzSXPh4XLwVB8IKPJUlTrHSbmrQH9dObdVVEH87TTIYf_zAMQnuAjwATOFaGYeCEva6hCTCCUy4l-YMmGGOaEoHxJtoK4RFjgOg20CZhAIKBmKB-rtpGezU0rkvPvLVJ4TrXPzhv0xMVbLV8pze2tWZo_tnkdNl4V9mQ3DfDQ6KSuZsWxez4vRSz5NpW7jkOx779TLhxbVPFUTcoM-yg9Vq1we5-1G10d3Z6O79IL6_Oi_nfy1RRwYdUcMmkpJnUuc4kJbqSmaa1yfNaCK6IsoYZlem4kgEtSc5pLUUteS0IEULTbTRd5fbePY02DOWiCca2reqsG0MJPCdUAjD8f8pYzgkQzCM9-EEf3ei7uEhUHCCjJJdRzVbKeBeCt3XZ-2ah_EsJuFxerPy6WLT7H4mjXtjqS36eKILDFVAmfPvtV9AbOweY1g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1561143298</pqid></control><display><type>article</type><title>Calibration-Free Ionophore-Based Ion-Selective Electrodes With a Co(II)/Co(III) Redox Couple-Based Solid Contact</title><source>American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list)</source><creator>Zou, Xu U. ; Zhen, Xue V. ; Cheong, Jia H. ; Bühlmann, Philippe</creator><creatorcontrib>Zou, Xu U. ; Zhen, Xue V. ; Cheong, Jia H. ; Bühlmann, Philippe</creatorcontrib><description>A high electrode-to-electrode reproducibility of the emf response of solid contact ion-selective electrodes (SC-ISEs) requires a precise control of the phase boundary potential between the ion-selective membrane (ISM) and the underlying electron conductor. To achieve this, we introduced previously ionophore-free ion exchanger membranes doped with a well controlled ratio of oxidized and reduced species of a redox couple as redox buffer and used them to make SC-ISEs that exhibited highly reproducible electrode-to-electrode potentials. Unfortunately, ionophores were found to promote the loss of insufficiently lipophilic species from the ionophore-doped ISMs into aqueous samples. Here we report on an improved redox buffer platform based on equimolar amounts of the much less hydrophilic Co(III) and Co(II) complexes of 4,4′-dinonyl-2,2′-bipyridyl, which makes it possible to extend the redox buffer approach to ionophore-based ISEs. For example, K+-selective electrodes based on the ionophore valinomycin exhibit electrode-to-electrode standard deviations as low as 0.7 mV after exposure of freshly prepared electrodes for 1 h to aqueous solutions. Exposure of freshly prepared ISE membranes to humidity prior to their first contact to electrolyte solution minimizes the initial (reproducible) emf drift. This redox buffer has also been successfully applied to sodium, potassium, calcium, hydrogen, and carbonate ion-selective electrodes, which all exhibit the high selectivity over interfering ions as expected for ionophore-doped ISE membranes.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/ac501625z</identifier><identifier>PMID: 25117517</identifier><identifier>CODEN: ANCHAM</identifier><language>eng</language><publisher>United States: American Chemical Society</publisher><subject>Analytical chemistry ; Aqueous solutions ; Buffers ; Calibration ; Contact ; Electrodes ; EMF ; Exposure ; Ion exchange ; Joining ; Membranes ; Phase boundaries</subject><ispartof>Analytical chemistry (Washington), 2014-09, Vol.86 (17), p.8687-8692</ispartof><rights>Copyright © 2014 American Chemical Society</rights><rights>Copyright American Chemical Society Sep 2, 2014</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a376t-768588348b9b4832bd84b3fc99f776a2aec5ca4b011c1b82963f87f86f72277b3</citedby><cites>FETCH-LOGICAL-a376t-768588348b9b4832bd84b3fc99f776a2aec5ca4b011c1b82963f87f86f72277b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25117517$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zou, Xu U.</creatorcontrib><creatorcontrib>Zhen, Xue V.</creatorcontrib><creatorcontrib>Cheong, Jia H.</creatorcontrib><creatorcontrib>Bühlmann, Philippe</creatorcontrib><title>Calibration-Free Ionophore-Based Ion-Selective Electrodes With a Co(II)/Co(III) Redox Couple-Based Solid Contact</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>A high electrode-to-electrode reproducibility of the emf response of solid contact ion-selective electrodes (SC-ISEs) requires a precise control of the phase boundary potential between the ion-selective membrane (ISM) and the underlying electron conductor. To achieve this, we introduced previously ionophore-free ion exchanger membranes doped with a well controlled ratio of oxidized and reduced species of a redox couple as redox buffer and used them to make SC-ISEs that exhibited highly reproducible electrode-to-electrode potentials. Unfortunately, ionophores were found to promote the loss of insufficiently lipophilic species from the ionophore-doped ISMs into aqueous samples. Here we report on an improved redox buffer platform based on equimolar amounts of the much less hydrophilic Co(III) and Co(II) complexes of 4,4′-dinonyl-2,2′-bipyridyl, which makes it possible to extend the redox buffer approach to ionophore-based ISEs. For example, K+-selective electrodes based on the ionophore valinomycin exhibit electrode-to-electrode standard deviations as low as 0.7 mV after exposure of freshly prepared electrodes for 1 h to aqueous solutions. Exposure of freshly prepared ISE membranes to humidity prior to their first contact to electrolyte solution minimizes the initial (reproducible) emf drift. This redox buffer has also been successfully applied to sodium, potassium, calcium, hydrogen, and carbonate ion-selective electrodes, which all exhibit the high selectivity over interfering ions as expected for ionophore-doped ISE membranes.</description><subject>Analytical chemistry</subject><subject>Aqueous solutions</subject><subject>Buffers</subject><subject>Calibration</subject><subject>Contact</subject><subject>Electrodes</subject><subject>EMF</subject><subject>Exposure</subject><subject>Ion exchange</subject><subject>Joining</subject><subject>Membranes</subject><subject>Phase boundaries</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNqF0VtL7DAQB_AgR3S9PPgFpCDC7kM1kzSXPh4XLwVB8IKPJUlTrHSbmrQH9dObdVVEH87TTIYf_zAMQnuAjwATOFaGYeCEva6hCTCCUy4l-YMmGGOaEoHxJtoK4RFjgOg20CZhAIKBmKB-rtpGezU0rkvPvLVJ4TrXPzhv0xMVbLV8pze2tWZo_tnkdNl4V9mQ3DfDQ6KSuZsWxez4vRSz5NpW7jkOx779TLhxbVPFUTcoM-yg9Vq1we5-1G10d3Z6O79IL6_Oi_nfy1RRwYdUcMmkpJnUuc4kJbqSmaa1yfNaCK6IsoYZlem4kgEtSc5pLUUteS0IEULTbTRd5fbePY02DOWiCca2reqsG0MJPCdUAjD8f8pYzgkQzCM9-EEf3ei7uEhUHCCjJJdRzVbKeBeCt3XZ-2ah_EsJuFxerPy6WLT7H4mjXtjqS36eKILDFVAmfPvtV9AbOweY1g</recordid><startdate>20140902</startdate><enddate>20140902</enddate><creator>Zou, Xu U.</creator><creator>Zhen, Xue V.</creator><creator>Cheong, Jia H.</creator><creator>Bühlmann, Philippe</creator><general>American Chemical Society</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TM</scope><scope>7U5</scope><scope>7U7</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>20140902</creationdate><title>Calibration-Free Ionophore-Based Ion-Selective Electrodes With a Co(II)/Co(III) Redox Couple-Based Solid Contact</title><author>Zou, Xu U. ; Zhen, Xue V. ; Cheong, Jia H. ; Bühlmann, Philippe</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a376t-768588348b9b4832bd84b3fc99f776a2aec5ca4b011c1b82963f87f86f72277b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Analytical chemistry</topic><topic>Aqueous solutions</topic><topic>Buffers</topic><topic>Calibration</topic><topic>Contact</topic><topic>Electrodes</topic><topic>EMF</topic><topic>Exposure</topic><topic>Ion exchange</topic><topic>Joining</topic><topic>Membranes</topic><topic>Phase boundaries</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zou, Xu U.</creatorcontrib><creatorcontrib>Zhen, Xue V.</creatorcontrib><creatorcontrib>Cheong, Jia H.</creatorcontrib><creatorcontrib>Bühlmann, Philippe</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zou, Xu U.</au><au>Zhen, Xue V.</au><au>Cheong, Jia H.</au><au>Bühlmann, Philippe</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Calibration-Free Ionophore-Based Ion-Selective Electrodes With a Co(II)/Co(III) Redox Couple-Based Solid Contact</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>2014-09-02</date><risdate>2014</risdate><volume>86</volume><issue>17</issue><spage>8687</spage><epage>8692</epage><pages>8687-8692</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><coden>ANCHAM</coden><abstract>A high electrode-to-electrode reproducibility of the emf response of solid contact ion-selective electrodes (SC-ISEs) requires a precise control of the phase boundary potential between the ion-selective membrane (ISM) and the underlying electron conductor. To achieve this, we introduced previously ionophore-free ion exchanger membranes doped with a well controlled ratio of oxidized and reduced species of a redox couple as redox buffer and used them to make SC-ISEs that exhibited highly reproducible electrode-to-electrode potentials. Unfortunately, ionophores were found to promote the loss of insufficiently lipophilic species from the ionophore-doped ISMs into aqueous samples. Here we report on an improved redox buffer platform based on equimolar amounts of the much less hydrophilic Co(III) and Co(II) complexes of 4,4′-dinonyl-2,2′-bipyridyl, which makes it possible to extend the redox buffer approach to ionophore-based ISEs. For example, K+-selective electrodes based on the ionophore valinomycin exhibit electrode-to-electrode standard deviations as low as 0.7 mV after exposure of freshly prepared electrodes for 1 h to aqueous solutions. Exposure of freshly prepared ISE membranes to humidity prior to their first contact to electrolyte solution minimizes the initial (reproducible) emf drift. This redox buffer has also been successfully applied to sodium, potassium, calcium, hydrogen, and carbonate ion-selective electrodes, which all exhibit the high selectivity over interfering ions as expected for ionophore-doped ISE membranes.</abstract><cop>United States</cop><pub>American Chemical Society</pub><pmid>25117517</pmid><doi>10.1021/ac501625z</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2700 |
ispartof | Analytical chemistry (Washington), 2014-09, Vol.86 (17), p.8687-8692 |
issn | 0003-2700 1520-6882 |
language | eng |
recordid | cdi_proquest_miscellaneous_1692381150 |
source | American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list) |
subjects | Analytical chemistry Aqueous solutions Buffers Calibration Contact Electrodes EMF Exposure Ion exchange Joining Membranes Phase boundaries |
title | Calibration-Free Ionophore-Based Ion-Selective Electrodes With a Co(II)/Co(III) Redox Couple-Based Solid Contact |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T14%3A25%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Calibration-Free%20Ionophore-Based%20Ion-Selective%20Electrodes%20With%20a%20Co(II)/Co(III)%20Redox%20Couple-Based%20Solid%20Contact&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Zou,%20Xu%20U.&rft.date=2014-09-02&rft.volume=86&rft.issue=17&rft.spage=8687&rft.epage=8692&rft.pages=8687-8692&rft.issn=0003-2700&rft.eissn=1520-6882&rft.coden=ANCHAM&rft_id=info:doi/10.1021/ac501625z&rft_dat=%3Cproquest_cross%3E3428050331%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a376t-768588348b9b4832bd84b3fc99f776a2aec5ca4b011c1b82963f87f86f72277b3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1561143298&rft_id=info:pmid/25117517&rfr_iscdi=true |