Loading…

Calibration-Free Ionophore-Based Ion-Selective Electrodes With a Co(II)/Co(III) Redox Couple-Based Solid Contact

A high electrode-to-electrode reproducibility of the emf response of solid contact ion-selective electrodes (SC-ISEs) requires a precise control of the phase boundary potential between the ion-selective membrane (ISM) and the underlying electron conductor. To achieve this, we introduced previously i...

Full description

Saved in:
Bibliographic Details
Published in:Analytical chemistry (Washington) 2014-09, Vol.86 (17), p.8687-8692
Main Authors: Zou, Xu U., Zhen, Xue V., Cheong, Jia H., Bühlmann, Philippe
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-a376t-768588348b9b4832bd84b3fc99f776a2aec5ca4b011c1b82963f87f86f72277b3
cites cdi_FETCH-LOGICAL-a376t-768588348b9b4832bd84b3fc99f776a2aec5ca4b011c1b82963f87f86f72277b3
container_end_page 8692
container_issue 17
container_start_page 8687
container_title Analytical chemistry (Washington)
container_volume 86
creator Zou, Xu U.
Zhen, Xue V.
Cheong, Jia H.
Bühlmann, Philippe
description A high electrode-to-electrode reproducibility of the emf response of solid contact ion-selective electrodes (SC-ISEs) requires a precise control of the phase boundary potential between the ion-selective membrane (ISM) and the underlying electron conductor. To achieve this, we introduced previously ionophore-free ion exchanger membranes doped with a well controlled ratio of oxidized and reduced species of a redox couple as redox buffer and used them to make SC-ISEs that exhibited highly reproducible electrode-to-electrode potentials. Unfortunately, ionophores were found to promote the loss of insufficiently lipophilic species from the ionophore-doped ISMs into aqueous samples. Here we report on an improved redox buffer platform based on equimolar amounts of the much less hydrophilic Co(III) and Co(II) complexes of 4,4′-dinonyl-2,2′-bipyridyl, which makes it possible to extend the redox buffer approach to ionophore-based ISEs. For example, K+-selective electrodes based on the ionophore valinomycin exhibit electrode-to-electrode standard deviations as low as 0.7 mV after exposure of freshly prepared electrodes for 1 h to aqueous solutions. Exposure of freshly prepared ISE membranes to humidity prior to their first contact to electrolyte solution minimizes the initial (reproducible) emf drift. This redox buffer has also been successfully applied to sodium, potassium, calcium, hydrogen, and carbonate ion-selective electrodes, which all exhibit the high selectivity over interfering ions as expected for ionophore-doped ISE membranes.
doi_str_mv 10.1021/ac501625z
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1692381150</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3428050331</sourcerecordid><originalsourceid>FETCH-LOGICAL-a376t-768588348b9b4832bd84b3fc99f776a2aec5ca4b011c1b82963f87f86f72277b3</originalsourceid><addsrcrecordid>eNqF0VtL7DAQB_AgR3S9PPgFpCDC7kM1kzSXPh4XLwVB8IKPJUlTrHSbmrQH9dObdVVEH87TTIYf_zAMQnuAjwATOFaGYeCEva6hCTCCUy4l-YMmGGOaEoHxJtoK4RFjgOg20CZhAIKBmKB-rtpGezU0rkvPvLVJ4TrXPzhv0xMVbLV8pze2tWZo_tnkdNl4V9mQ3DfDQ6KSuZsWxez4vRSz5NpW7jkOx779TLhxbVPFUTcoM-yg9Vq1we5-1G10d3Z6O79IL6_Oi_nfy1RRwYdUcMmkpJnUuc4kJbqSmaa1yfNaCK6IsoYZlem4kgEtSc5pLUUteS0IEULTbTRd5fbePY02DOWiCca2reqsG0MJPCdUAjD8f8pYzgkQzCM9-EEf3ei7uEhUHCCjJJdRzVbKeBeCt3XZ-2ah_EsJuFxerPy6WLT7H4mjXtjqS36eKILDFVAmfPvtV9AbOweY1g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1561143298</pqid></control><display><type>article</type><title>Calibration-Free Ionophore-Based Ion-Selective Electrodes With a Co(II)/Co(III) Redox Couple-Based Solid Contact</title><source>American Chemical Society:Jisc Collections:American Chemical Society Read &amp; Publish Agreement 2022-2024 (Reading list)</source><creator>Zou, Xu U. ; Zhen, Xue V. ; Cheong, Jia H. ; Bühlmann, Philippe</creator><creatorcontrib>Zou, Xu U. ; Zhen, Xue V. ; Cheong, Jia H. ; Bühlmann, Philippe</creatorcontrib><description>A high electrode-to-electrode reproducibility of the emf response of solid contact ion-selective electrodes (SC-ISEs) requires a precise control of the phase boundary potential between the ion-selective membrane (ISM) and the underlying electron conductor. To achieve this, we introduced previously ionophore-free ion exchanger membranes doped with a well controlled ratio of oxidized and reduced species of a redox couple as redox buffer and used them to make SC-ISEs that exhibited highly reproducible electrode-to-electrode potentials. Unfortunately, ionophores were found to promote the loss of insufficiently lipophilic species from the ionophore-doped ISMs into aqueous samples. Here we report on an improved redox buffer platform based on equimolar amounts of the much less hydrophilic Co(III) and Co(II) complexes of 4,4′-dinonyl-2,2′-bipyridyl, which makes it possible to extend the redox buffer approach to ionophore-based ISEs. For example, K+-selective electrodes based on the ionophore valinomycin exhibit electrode-to-electrode standard deviations as low as 0.7 mV after exposure of freshly prepared electrodes for 1 h to aqueous solutions. Exposure of freshly prepared ISE membranes to humidity prior to their first contact to electrolyte solution minimizes the initial (reproducible) emf drift. This redox buffer has also been successfully applied to sodium, potassium, calcium, hydrogen, and carbonate ion-selective electrodes, which all exhibit the high selectivity over interfering ions as expected for ionophore-doped ISE membranes.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/ac501625z</identifier><identifier>PMID: 25117517</identifier><identifier>CODEN: ANCHAM</identifier><language>eng</language><publisher>United States: American Chemical Society</publisher><subject>Analytical chemistry ; Aqueous solutions ; Buffers ; Calibration ; Contact ; Electrodes ; EMF ; Exposure ; Ion exchange ; Joining ; Membranes ; Phase boundaries</subject><ispartof>Analytical chemistry (Washington), 2014-09, Vol.86 (17), p.8687-8692</ispartof><rights>Copyright © 2014 American Chemical Society</rights><rights>Copyright American Chemical Society Sep 2, 2014</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a376t-768588348b9b4832bd84b3fc99f776a2aec5ca4b011c1b82963f87f86f72277b3</citedby><cites>FETCH-LOGICAL-a376t-768588348b9b4832bd84b3fc99f776a2aec5ca4b011c1b82963f87f86f72277b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25117517$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zou, Xu U.</creatorcontrib><creatorcontrib>Zhen, Xue V.</creatorcontrib><creatorcontrib>Cheong, Jia H.</creatorcontrib><creatorcontrib>Bühlmann, Philippe</creatorcontrib><title>Calibration-Free Ionophore-Based Ion-Selective Electrodes With a Co(II)/Co(III) Redox Couple-Based Solid Contact</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>A high electrode-to-electrode reproducibility of the emf response of solid contact ion-selective electrodes (SC-ISEs) requires a precise control of the phase boundary potential between the ion-selective membrane (ISM) and the underlying electron conductor. To achieve this, we introduced previously ionophore-free ion exchanger membranes doped with a well controlled ratio of oxidized and reduced species of a redox couple as redox buffer and used them to make SC-ISEs that exhibited highly reproducible electrode-to-electrode potentials. Unfortunately, ionophores were found to promote the loss of insufficiently lipophilic species from the ionophore-doped ISMs into aqueous samples. Here we report on an improved redox buffer platform based on equimolar amounts of the much less hydrophilic Co(III) and Co(II) complexes of 4,4′-dinonyl-2,2′-bipyridyl, which makes it possible to extend the redox buffer approach to ionophore-based ISEs. For example, K+-selective electrodes based on the ionophore valinomycin exhibit electrode-to-electrode standard deviations as low as 0.7 mV after exposure of freshly prepared electrodes for 1 h to aqueous solutions. Exposure of freshly prepared ISE membranes to humidity prior to their first contact to electrolyte solution minimizes the initial (reproducible) emf drift. This redox buffer has also been successfully applied to sodium, potassium, calcium, hydrogen, and carbonate ion-selective electrodes, which all exhibit the high selectivity over interfering ions as expected for ionophore-doped ISE membranes.</description><subject>Analytical chemistry</subject><subject>Aqueous solutions</subject><subject>Buffers</subject><subject>Calibration</subject><subject>Contact</subject><subject>Electrodes</subject><subject>EMF</subject><subject>Exposure</subject><subject>Ion exchange</subject><subject>Joining</subject><subject>Membranes</subject><subject>Phase boundaries</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNqF0VtL7DAQB_AgR3S9PPgFpCDC7kM1kzSXPh4XLwVB8IKPJUlTrHSbmrQH9dObdVVEH87TTIYf_zAMQnuAjwATOFaGYeCEva6hCTCCUy4l-YMmGGOaEoHxJtoK4RFjgOg20CZhAIKBmKB-rtpGezU0rkvPvLVJ4TrXPzhv0xMVbLV8pze2tWZo_tnkdNl4V9mQ3DfDQ6KSuZsWxez4vRSz5NpW7jkOx779TLhxbVPFUTcoM-yg9Vq1we5-1G10d3Z6O79IL6_Oi_nfy1RRwYdUcMmkpJnUuc4kJbqSmaa1yfNaCK6IsoYZlem4kgEtSc5pLUUteS0IEULTbTRd5fbePY02DOWiCca2reqsG0MJPCdUAjD8f8pYzgkQzCM9-EEf3ei7uEhUHCCjJJdRzVbKeBeCt3XZ-2ah_EsJuFxerPy6WLT7H4mjXtjqS36eKILDFVAmfPvtV9AbOweY1g</recordid><startdate>20140902</startdate><enddate>20140902</enddate><creator>Zou, Xu U.</creator><creator>Zhen, Xue V.</creator><creator>Cheong, Jia H.</creator><creator>Bühlmann, Philippe</creator><general>American Chemical Society</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TM</scope><scope>7U5</scope><scope>7U7</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>20140902</creationdate><title>Calibration-Free Ionophore-Based Ion-Selective Electrodes With a Co(II)/Co(III) Redox Couple-Based Solid Contact</title><author>Zou, Xu U. ; Zhen, Xue V. ; Cheong, Jia H. ; Bühlmann, Philippe</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a376t-768588348b9b4832bd84b3fc99f776a2aec5ca4b011c1b82963f87f86f72277b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Analytical chemistry</topic><topic>Aqueous solutions</topic><topic>Buffers</topic><topic>Calibration</topic><topic>Contact</topic><topic>Electrodes</topic><topic>EMF</topic><topic>Exposure</topic><topic>Ion exchange</topic><topic>Joining</topic><topic>Membranes</topic><topic>Phase boundaries</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zou, Xu U.</creatorcontrib><creatorcontrib>Zhen, Xue V.</creatorcontrib><creatorcontrib>Cheong, Jia H.</creatorcontrib><creatorcontrib>Bühlmann, Philippe</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zou, Xu U.</au><au>Zhen, Xue V.</au><au>Cheong, Jia H.</au><au>Bühlmann, Philippe</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Calibration-Free Ionophore-Based Ion-Selective Electrodes With a Co(II)/Co(III) Redox Couple-Based Solid Contact</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>2014-09-02</date><risdate>2014</risdate><volume>86</volume><issue>17</issue><spage>8687</spage><epage>8692</epage><pages>8687-8692</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><coden>ANCHAM</coden><abstract>A high electrode-to-electrode reproducibility of the emf response of solid contact ion-selective electrodes (SC-ISEs) requires a precise control of the phase boundary potential between the ion-selective membrane (ISM) and the underlying electron conductor. To achieve this, we introduced previously ionophore-free ion exchanger membranes doped with a well controlled ratio of oxidized and reduced species of a redox couple as redox buffer and used them to make SC-ISEs that exhibited highly reproducible electrode-to-electrode potentials. Unfortunately, ionophores were found to promote the loss of insufficiently lipophilic species from the ionophore-doped ISMs into aqueous samples. Here we report on an improved redox buffer platform based on equimolar amounts of the much less hydrophilic Co(III) and Co(II) complexes of 4,4′-dinonyl-2,2′-bipyridyl, which makes it possible to extend the redox buffer approach to ionophore-based ISEs. For example, K+-selective electrodes based on the ionophore valinomycin exhibit electrode-to-electrode standard deviations as low as 0.7 mV after exposure of freshly prepared electrodes for 1 h to aqueous solutions. Exposure of freshly prepared ISE membranes to humidity prior to their first contact to electrolyte solution minimizes the initial (reproducible) emf drift. This redox buffer has also been successfully applied to sodium, potassium, calcium, hydrogen, and carbonate ion-selective electrodes, which all exhibit the high selectivity over interfering ions as expected for ionophore-doped ISE membranes.</abstract><cop>United States</cop><pub>American Chemical Society</pub><pmid>25117517</pmid><doi>10.1021/ac501625z</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2700
ispartof Analytical chemistry (Washington), 2014-09, Vol.86 (17), p.8687-8692
issn 0003-2700
1520-6882
language eng
recordid cdi_proquest_miscellaneous_1692381150
source American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list)
subjects Analytical chemistry
Aqueous solutions
Buffers
Calibration
Contact
Electrodes
EMF
Exposure
Ion exchange
Joining
Membranes
Phase boundaries
title Calibration-Free Ionophore-Based Ion-Selective Electrodes With a Co(II)/Co(III) Redox Couple-Based Solid Contact
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T14%3A25%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Calibration-Free%20Ionophore-Based%20Ion-Selective%20Electrodes%20With%20a%20Co(II)/Co(III)%20Redox%20Couple-Based%20Solid%20Contact&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Zou,%20Xu%20U.&rft.date=2014-09-02&rft.volume=86&rft.issue=17&rft.spage=8687&rft.epage=8692&rft.pages=8687-8692&rft.issn=0003-2700&rft.eissn=1520-6882&rft.coden=ANCHAM&rft_id=info:doi/10.1021/ac501625z&rft_dat=%3Cproquest_cross%3E3428050331%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a376t-768588348b9b4832bd84b3fc99f776a2aec5ca4b011c1b82963f87f86f72277b3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1561143298&rft_id=info:pmid/25117517&rfr_iscdi=true