All-Solid-State Reference Electrodes Based on Colloid-Imprinted Mesoporous Carbon and Their Application in Disposable Paper-based Potentiometric Sensing Devices

Reference electrodes are used in almost every electroanalytical measurement. Here, all-solid-state reference electrodes are described that employ colloid-imprinted mesoporous (CIM) carbon as solid contact and a poly­(vinyl chloride) reference membrane to contact the sample. Such a reference membrane...

Full description

Saved in:
Bibliographic Details
Published in:Analytical chemistry (Washington) 2015-03, Vol.87 (5), p.2981-2987
Main Authors: Hu, Jinbo, Ho, Kieu T, Zou, Xu U, Smyrl, William H, Stein, Andreas, Bühlmann, Philippe
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-a376t-4dabf5378e3dd67874d7fc71435a9e5daefda0e16a215fec4fdb9e05ab82913c3
cites cdi_FETCH-LOGICAL-a376t-4dabf5378e3dd67874d7fc71435a9e5daefda0e16a215fec4fdb9e05ab82913c3
container_end_page 2987
container_issue 5
container_start_page 2981
container_title Analytical chemistry (Washington)
container_volume 87
creator Hu, Jinbo
Ho, Kieu T
Zou, Xu U
Smyrl, William H
Stein, Andreas
Bühlmann, Philippe
description Reference electrodes are used in almost every electroanalytical measurement. Here, all-solid-state reference electrodes are described that employ colloid-imprinted mesoporous (CIM) carbon as solid contact and a poly­(vinyl chloride) reference membrane to contact the sample. Such a reference membrane is doped with a moderately hydrophilic ionic liquid and a hydrophobic redox couple, leading to well-defined constant potentials at the interfaces of this membrane to the sample and to the solid contact, respectively. Due to the intrinsic properties of CIM carbon, reference electrodes with a CIM carbon solid contact exhibit excellent resistance to common interfering agents such as light and O2, with outstanding potential stability in continuous potentiometric measurements. The potential drift of CIM carbon-based reference electrodes without redox couple is as low as 1.7 μV/h over 110 h, making them the most stable all-solid-state reference electrodes reported so far. To demonstrate the compatibility of CIM carbon-based reference electrodes with miniaturized potentiometric systems, these reference electrodes were integrated into paper-based potentiometric sensing devices, successfully replacing the conventional reference electrode with its reference electrolyte solution. As a proof of concept, disposable paper-based Cl– sensing devices that contain stencil-printed Ag/AgCl-based Cl– selective electrodes and CIM carbon-based reference electrodes were constructed. These sensing devices are inexpensive, easy to use, and offer highly reproducible Cl– measurements with sample volumes as low as 10 μL.
doi_str_mv 10.1021/ac504556s
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_1692400364</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3618136431</sourcerecordid><originalsourceid>FETCH-LOGICAL-a376t-4dabf5378e3dd67874d7fc71435a9e5daefda0e16a215fec4fdb9e05ab82913c3</originalsourceid><addsrcrecordid>eNqN0cGKFDEQBuAgijuuHnwBCYigh9ZKdyfpOY6zqy6suDjrualOqjVLOmmTHsG38VHNOusievEUKD7-UPUz9ljASwG1eIVGQiulynfYSsgaKtV19V22AoCmqjXAEXuQ8xWAECDUfXZUS9WAbtsV-7HxvtpF72y1W3Ah_pFGShQM8VNPZknRUuavMZPlMfBt9D4WezbNyYWlDN9TjnNMcZ_5FtNQDAbLL7-QS3wzz94ZXFyZusBPXJ5jxsETv8CZUjX8ir2IC4ViJlqSM3xHIbvwmZ_QN2coP2T3RvSZHt28x-zTm9PL7bvq_MPbs-3mvMJGq6VqLQ6jbHRHjbVKd7q1ejRatI3ENUmLNFoEEgprIUcy7WiHNYHEoavXojHNMXt-yJ1T_LqnvPSTy4a8x0BluV6odd2We6r2P6gCpUSjZaFP_6JXcZ9CWeRaFQJaQ1EvDsqkmHOisS_XnTB97wX01w33tw0X--QmcT9MZG_l70oLeHYAaPIfv_0T9BNXjq6t</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1661370770</pqid></control><display><type>article</type><title>All-Solid-State Reference Electrodes Based on Colloid-Imprinted Mesoporous Carbon and Their Application in Disposable Paper-based Potentiometric Sensing Devices</title><source>American Chemical Society:Jisc Collections:American Chemical Society Read &amp; Publish Agreement 2022-2024 (Reading list)</source><creator>Hu, Jinbo ; Ho, Kieu T ; Zou, Xu U ; Smyrl, William H ; Stein, Andreas ; Bühlmann, Philippe</creator><creatorcontrib>Hu, Jinbo ; Ho, Kieu T ; Zou, Xu U ; Smyrl, William H ; Stein, Andreas ; Bühlmann, Philippe</creatorcontrib><description>Reference electrodes are used in almost every electroanalytical measurement. Here, all-solid-state reference electrodes are described that employ colloid-imprinted mesoporous (CIM) carbon as solid contact and a poly­(vinyl chloride) reference membrane to contact the sample. Such a reference membrane is doped with a moderately hydrophilic ionic liquid and a hydrophobic redox couple, leading to well-defined constant potentials at the interfaces of this membrane to the sample and to the solid contact, respectively. Due to the intrinsic properties of CIM carbon, reference electrodes with a CIM carbon solid contact exhibit excellent resistance to common interfering agents such as light and O2, with outstanding potential stability in continuous potentiometric measurements. The potential drift of CIM carbon-based reference electrodes without redox couple is as low as 1.7 μV/h over 110 h, making them the most stable all-solid-state reference electrodes reported so far. To demonstrate the compatibility of CIM carbon-based reference electrodes with miniaturized potentiometric systems, these reference electrodes were integrated into paper-based potentiometric sensing devices, successfully replacing the conventional reference electrode with its reference electrolyte solution. As a proof of concept, disposable paper-based Cl– sensing devices that contain stencil-printed Ag/AgCl-based Cl– selective electrodes and CIM carbon-based reference electrodes were constructed. These sensing devices are inexpensive, easy to use, and offer highly reproducible Cl– measurements with sample volumes as low as 10 μL.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/ac504556s</identifier><identifier>PMID: 25630744</identifier><identifier>CODEN: ANCHAM</identifier><language>eng</language><publisher>United States: American Chemical Society</publisher><subject>Carbon ; Colloids ; Computer integrated manufacturing ; Contact ; Electrodes ; Joining ; Membranes ; Porosity ; Sensing devices ; Solids</subject><ispartof>Analytical chemistry (Washington), 2015-03, Vol.87 (5), p.2981-2987</ispartof><rights>Copyright American Chemical Society Mar 3, 2015</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a376t-4dabf5378e3dd67874d7fc71435a9e5daefda0e16a215fec4fdb9e05ab82913c3</citedby><cites>FETCH-LOGICAL-a376t-4dabf5378e3dd67874d7fc71435a9e5daefda0e16a215fec4fdb9e05ab82913c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25630744$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hu, Jinbo</creatorcontrib><creatorcontrib>Ho, Kieu T</creatorcontrib><creatorcontrib>Zou, Xu U</creatorcontrib><creatorcontrib>Smyrl, William H</creatorcontrib><creatorcontrib>Stein, Andreas</creatorcontrib><creatorcontrib>Bühlmann, Philippe</creatorcontrib><title>All-Solid-State Reference Electrodes Based on Colloid-Imprinted Mesoporous Carbon and Their Application in Disposable Paper-based Potentiometric Sensing Devices</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>Reference electrodes are used in almost every electroanalytical measurement. Here, all-solid-state reference electrodes are described that employ colloid-imprinted mesoporous (CIM) carbon as solid contact and a poly­(vinyl chloride) reference membrane to contact the sample. Such a reference membrane is doped with a moderately hydrophilic ionic liquid and a hydrophobic redox couple, leading to well-defined constant potentials at the interfaces of this membrane to the sample and to the solid contact, respectively. Due to the intrinsic properties of CIM carbon, reference electrodes with a CIM carbon solid contact exhibit excellent resistance to common interfering agents such as light and O2, with outstanding potential stability in continuous potentiometric measurements. The potential drift of CIM carbon-based reference electrodes without redox couple is as low as 1.7 μV/h over 110 h, making them the most stable all-solid-state reference electrodes reported so far. To demonstrate the compatibility of CIM carbon-based reference electrodes with miniaturized potentiometric systems, these reference electrodes were integrated into paper-based potentiometric sensing devices, successfully replacing the conventional reference electrode with its reference electrolyte solution. As a proof of concept, disposable paper-based Cl– sensing devices that contain stencil-printed Ag/AgCl-based Cl– selective electrodes and CIM carbon-based reference electrodes were constructed. These sensing devices are inexpensive, easy to use, and offer highly reproducible Cl– measurements with sample volumes as low as 10 μL.</description><subject>Carbon</subject><subject>Colloids</subject><subject>Computer integrated manufacturing</subject><subject>Contact</subject><subject>Electrodes</subject><subject>Joining</subject><subject>Membranes</subject><subject>Porosity</subject><subject>Sensing devices</subject><subject>Solids</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNqN0cGKFDEQBuAgijuuHnwBCYigh9ZKdyfpOY6zqy6suDjrualOqjVLOmmTHsG38VHNOusievEUKD7-UPUz9ljASwG1eIVGQiulynfYSsgaKtV19V22AoCmqjXAEXuQ8xWAECDUfXZUS9WAbtsV-7HxvtpF72y1W3Ah_pFGShQM8VNPZknRUuavMZPlMfBt9D4WezbNyYWlDN9TjnNMcZ_5FtNQDAbLL7-QS3wzz94ZXFyZusBPXJ5jxsETv8CZUjX8ir2IC4ViJlqSM3xHIbvwmZ_QN2coP2T3RvSZHt28x-zTm9PL7bvq_MPbs-3mvMJGq6VqLQ6jbHRHjbVKd7q1ejRatI3ENUmLNFoEEgprIUcy7WiHNYHEoavXojHNMXt-yJ1T_LqnvPSTy4a8x0BluV6odd2We6r2P6gCpUSjZaFP_6JXcZ9CWeRaFQJaQ1EvDsqkmHOisS_XnTB97wX01w33tw0X--QmcT9MZG_l70oLeHYAaPIfv_0T9BNXjq6t</recordid><startdate>20150303</startdate><enddate>20150303</enddate><creator>Hu, Jinbo</creator><creator>Ho, Kieu T</creator><creator>Zou, Xu U</creator><creator>Smyrl, William H</creator><creator>Stein, Andreas</creator><creator>Bühlmann, Philippe</creator><general>American Chemical Society</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TM</scope><scope>7U5</scope><scope>7U7</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>20150303</creationdate><title>All-Solid-State Reference Electrodes Based on Colloid-Imprinted Mesoporous Carbon and Their Application in Disposable Paper-based Potentiometric Sensing Devices</title><author>Hu, Jinbo ; Ho, Kieu T ; Zou, Xu U ; Smyrl, William H ; Stein, Andreas ; Bühlmann, Philippe</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a376t-4dabf5378e3dd67874d7fc71435a9e5daefda0e16a215fec4fdb9e05ab82913c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Carbon</topic><topic>Colloids</topic><topic>Computer integrated manufacturing</topic><topic>Contact</topic><topic>Electrodes</topic><topic>Joining</topic><topic>Membranes</topic><topic>Porosity</topic><topic>Sensing devices</topic><topic>Solids</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hu, Jinbo</creatorcontrib><creatorcontrib>Ho, Kieu T</creatorcontrib><creatorcontrib>Zou, Xu U</creatorcontrib><creatorcontrib>Smyrl, William H</creatorcontrib><creatorcontrib>Stein, Andreas</creatorcontrib><creatorcontrib>Bühlmann, Philippe</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hu, Jinbo</au><au>Ho, Kieu T</au><au>Zou, Xu U</au><au>Smyrl, William H</au><au>Stein, Andreas</au><au>Bühlmann, Philippe</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>All-Solid-State Reference Electrodes Based on Colloid-Imprinted Mesoporous Carbon and Their Application in Disposable Paper-based Potentiometric Sensing Devices</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>2015-03-03</date><risdate>2015</risdate><volume>87</volume><issue>5</issue><spage>2981</spage><epage>2987</epage><pages>2981-2987</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><coden>ANCHAM</coden><abstract>Reference electrodes are used in almost every electroanalytical measurement. Here, all-solid-state reference electrodes are described that employ colloid-imprinted mesoporous (CIM) carbon as solid contact and a poly­(vinyl chloride) reference membrane to contact the sample. Such a reference membrane is doped with a moderately hydrophilic ionic liquid and a hydrophobic redox couple, leading to well-defined constant potentials at the interfaces of this membrane to the sample and to the solid contact, respectively. Due to the intrinsic properties of CIM carbon, reference electrodes with a CIM carbon solid contact exhibit excellent resistance to common interfering agents such as light and O2, with outstanding potential stability in continuous potentiometric measurements. The potential drift of CIM carbon-based reference electrodes without redox couple is as low as 1.7 μV/h over 110 h, making them the most stable all-solid-state reference electrodes reported so far. To demonstrate the compatibility of CIM carbon-based reference electrodes with miniaturized potentiometric systems, these reference electrodes were integrated into paper-based potentiometric sensing devices, successfully replacing the conventional reference electrode with its reference electrolyte solution. As a proof of concept, disposable paper-based Cl– sensing devices that contain stencil-printed Ag/AgCl-based Cl– selective electrodes and CIM carbon-based reference electrodes were constructed. These sensing devices are inexpensive, easy to use, and offer highly reproducible Cl– measurements with sample volumes as low as 10 μL.</abstract><cop>United States</cop><pub>American Chemical Society</pub><pmid>25630744</pmid><doi>10.1021/ac504556s</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2700
ispartof Analytical chemistry (Washington), 2015-03, Vol.87 (5), p.2981-2987
issn 0003-2700
1520-6882
language eng
recordid cdi_proquest_miscellaneous_1692400364
source American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list)
subjects Carbon
Colloids
Computer integrated manufacturing
Contact
Electrodes
Joining
Membranes
Porosity
Sensing devices
Solids
title All-Solid-State Reference Electrodes Based on Colloid-Imprinted Mesoporous Carbon and Their Application in Disposable Paper-based Potentiometric Sensing Devices
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T13%3A06%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=All-Solid-State%20Reference%20Electrodes%20Based%20on%20Colloid-Imprinted%20Mesoporous%20Carbon%20and%20Their%20Application%20in%20Disposable%20Paper-based%20Potentiometric%20Sensing%20Devices&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Hu,%20Jinbo&rft.date=2015-03-03&rft.volume=87&rft.issue=5&rft.spage=2981&rft.epage=2987&rft.pages=2981-2987&rft.issn=0003-2700&rft.eissn=1520-6882&rft.coden=ANCHAM&rft_id=info:doi/10.1021/ac504556s&rft_dat=%3Cproquest_cross%3E3618136431%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a376t-4dabf5378e3dd67874d7fc71435a9e5daefda0e16a215fec4fdb9e05ab82913c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1661370770&rft_id=info:pmid/25630744&rfr_iscdi=true