Rapid Microbial Sample Preparation from Blood Using a Novel Concentration Device: e0116837

Appropriate care for bacteremic patients is dictated by the amount of time needed for an accurate diagnosis. However, the concentration of microbes in the blood is extremely low in these patients (1-100 CFU/mL), traditionally requiring growth (blood culture) or amplification (e.g., PCR) for detectio...

Full description

Saved in:
Bibliographic Details
Published in:PloS one 2015-02, Vol.10 (2)
Main Authors: Boardman, Anna K, Campbell, Jennifer, Wirz, Holger, Sharon, Andre, Sauer-Budge, Alexis F
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page
container_issue 2
container_start_page
container_title PloS one
container_volume 10
creator Boardman, Anna K
Campbell, Jennifer
Wirz, Holger
Sharon, Andre
Sauer-Budge, Alexis F
description Appropriate care for bacteremic patients is dictated by the amount of time needed for an accurate diagnosis. However, the concentration of microbes in the blood is extremely low in these patients (1-100 CFU/mL), traditionally requiring growth (blood culture) or amplification (e.g., PCR) for detection. Current culture-based methods can take a minimum of two days, while faster methods like PCR require a sample free of inhibitors (i.e., blood components). Though commercial kits exist for the removal of blood from these samples, they typically capture only DNA, thereby necessitating the use of blood culture for antimicrobial testing. Here, we report a novel, scaled-up sample preparation protocol carried out in a new microbial concentration device. The process can efficiently lyse 10 mL of bacteremic blood while maintaining the microorganisms' viability, giving a 30- mu L final output volume. A suite of six microorganisms (Staphylococcus aureus, Streptococcus pneumoniae, Escherichia coli, Haemophilus influenzae, Pseudomonas aeruginosa, and Candida albicans) at a range of clinically relevant concentrations was tested. All of the microorganisms had recoveries greater than 55% at the highest tested concentration of 100 CFU/mL, with three of them having over 70% recovery. At the lowest tested concentration of 3 CFU/mL, two microorganisms had recoveries of ca. 40-50% while the other four gave recoveries greater than 70%. Using a Taqman assay for methicillin-sensitive S. aureus (MSSA)to prove the feasibility of downstream analysis, we show that our microbial pellets are clean enough for PCR amplification. PCR testing of 56 spiked-positive and negative samples gave a specificity of 0.97 and a sensitivity of 0.96, showing that our sample preparation protocol holds great promise for the rapid diagnosis of bacteremia directly from a primary sample.
doi_str_mv 10.1371/journal.pone.0116837
format article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_1694979620</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1694979620</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_16949796203</originalsourceid><addsrcrecordid>eNqVjrtuAjEQAK1IkQIhf5BiSxouNiY-jpKXaEAISJMGLccSGfm8xr7j-xHS_UCqaUaaEeJTyUzpXH1duYkeXRbYUyaVMmOdv4iOKvRwYIZSv4luSlcpv_XYmI743WGwZ1jbMvLJooM9VsERbCMFjFhb9nCJXMHUMZ_hJ1n_BwgbvpODGfuSfN1qc7rbkiZAbbUnXi_oEn20fBf95eIwWw1C5FtDqT5WNpXkHHriJh2VKUZFXjwn_6E-ABOPTGw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1694979620</pqid></control><display><type>article</type><title>Rapid Microbial Sample Preparation from Blood Using a Novel Concentration Device: e0116837</title><source>Open Access: PubMed Central</source><source>Publicly Available Content Database</source><creator>Boardman, Anna K ; Campbell, Jennifer ; Wirz, Holger ; Sharon, Andre ; Sauer-Budge, Alexis F</creator><creatorcontrib>Boardman, Anna K ; Campbell, Jennifer ; Wirz, Holger ; Sharon, Andre ; Sauer-Budge, Alexis F</creatorcontrib><description>Appropriate care for bacteremic patients is dictated by the amount of time needed for an accurate diagnosis. However, the concentration of microbes in the blood is extremely low in these patients (1-100 CFU/mL), traditionally requiring growth (blood culture) or amplification (e.g., PCR) for detection. Current culture-based methods can take a minimum of two days, while faster methods like PCR require a sample free of inhibitors (i.e., blood components). Though commercial kits exist for the removal of blood from these samples, they typically capture only DNA, thereby necessitating the use of blood culture for antimicrobial testing. Here, we report a novel, scaled-up sample preparation protocol carried out in a new microbial concentration device. The process can efficiently lyse 10 mL of bacteremic blood while maintaining the microorganisms' viability, giving a 30- mu L final output volume. A suite of six microorganisms (Staphylococcus aureus, Streptococcus pneumoniae, Escherichia coli, Haemophilus influenzae, Pseudomonas aeruginosa, and Candida albicans) at a range of clinically relevant concentrations was tested. All of the microorganisms had recoveries greater than 55% at the highest tested concentration of 100 CFU/mL, with three of them having over 70% recovery. At the lowest tested concentration of 3 CFU/mL, two microorganisms had recoveries of ca. 40-50% while the other four gave recoveries greater than 70%. Using a Taqman assay for methicillin-sensitive S. aureus (MSSA)to prove the feasibility of downstream analysis, we show that our microbial pellets are clean enough for PCR amplification. PCR testing of 56 spiked-positive and negative samples gave a specificity of 0.97 and a sensitivity of 0.96, showing that our sample preparation protocol holds great promise for the rapid diagnosis of bacteremia directly from a primary sample.</description><identifier>EISSN: 1932-6203</identifier><identifier>DOI: 10.1371/journal.pone.0116837</identifier><language>eng</language><subject>Candida albicans ; Escherichia coli ; Haemophilus influenzae ; Pseudomonas aeruginosa ; Staphylococcus aureus ; Streptococcus pneumoniae</subject><ispartof>PloS one, 2015-02, Vol.10 (2)</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925,37013</link.rule.ids></links><search><creatorcontrib>Boardman, Anna K</creatorcontrib><creatorcontrib>Campbell, Jennifer</creatorcontrib><creatorcontrib>Wirz, Holger</creatorcontrib><creatorcontrib>Sharon, Andre</creatorcontrib><creatorcontrib>Sauer-Budge, Alexis F</creatorcontrib><title>Rapid Microbial Sample Preparation from Blood Using a Novel Concentration Device: e0116837</title><title>PloS one</title><description>Appropriate care for bacteremic patients is dictated by the amount of time needed for an accurate diagnosis. However, the concentration of microbes in the blood is extremely low in these patients (1-100 CFU/mL), traditionally requiring growth (blood culture) or amplification (e.g., PCR) for detection. Current culture-based methods can take a minimum of two days, while faster methods like PCR require a sample free of inhibitors (i.e., blood components). Though commercial kits exist for the removal of blood from these samples, they typically capture only DNA, thereby necessitating the use of blood culture for antimicrobial testing. Here, we report a novel, scaled-up sample preparation protocol carried out in a new microbial concentration device. The process can efficiently lyse 10 mL of bacteremic blood while maintaining the microorganisms' viability, giving a 30- mu L final output volume. A suite of six microorganisms (Staphylococcus aureus, Streptococcus pneumoniae, Escherichia coli, Haemophilus influenzae, Pseudomonas aeruginosa, and Candida albicans) at a range of clinically relevant concentrations was tested. All of the microorganisms had recoveries greater than 55% at the highest tested concentration of 100 CFU/mL, with three of them having over 70% recovery. At the lowest tested concentration of 3 CFU/mL, two microorganisms had recoveries of ca. 40-50% while the other four gave recoveries greater than 70%. Using a Taqman assay for methicillin-sensitive S. aureus (MSSA)to prove the feasibility of downstream analysis, we show that our microbial pellets are clean enough for PCR amplification. PCR testing of 56 spiked-positive and negative samples gave a specificity of 0.97 and a sensitivity of 0.96, showing that our sample preparation protocol holds great promise for the rapid diagnosis of bacteremia directly from a primary sample.</description><subject>Candida albicans</subject><subject>Escherichia coli</subject><subject>Haemophilus influenzae</subject><subject>Pseudomonas aeruginosa</subject><subject>Staphylococcus aureus</subject><subject>Streptococcus pneumoniae</subject><issn>1932-6203</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNqVjrtuAjEQAK1IkQIhf5BiSxouNiY-jpKXaEAISJMGLccSGfm8xr7j-xHS_UCqaUaaEeJTyUzpXH1duYkeXRbYUyaVMmOdv4iOKvRwYIZSv4luSlcpv_XYmI743WGwZ1jbMvLJooM9VsERbCMFjFhb9nCJXMHUMZ_hJ1n_BwgbvpODGfuSfN1qc7rbkiZAbbUnXi_oEn20fBf95eIwWw1C5FtDqT5WNpXkHHriJh2VKUZFXjwn_6E-ABOPTGw</recordid><startdate>20150201</startdate><enddate>20150201</enddate><creator>Boardman, Anna K</creator><creator>Campbell, Jennifer</creator><creator>Wirz, Holger</creator><creator>Sharon, Andre</creator><creator>Sauer-Budge, Alexis F</creator><scope>7T7</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>P64</scope></search><sort><creationdate>20150201</creationdate><title>Rapid Microbial Sample Preparation from Blood Using a Novel Concentration Device: e0116837</title><author>Boardman, Anna K ; Campbell, Jennifer ; Wirz, Holger ; Sharon, Andre ; Sauer-Budge, Alexis F</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_16949796203</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Candida albicans</topic><topic>Escherichia coli</topic><topic>Haemophilus influenzae</topic><topic>Pseudomonas aeruginosa</topic><topic>Staphylococcus aureus</topic><topic>Streptococcus pneumoniae</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Boardman, Anna K</creatorcontrib><creatorcontrib>Campbell, Jennifer</creatorcontrib><creatorcontrib>Wirz, Holger</creatorcontrib><creatorcontrib>Sharon, Andre</creatorcontrib><creatorcontrib>Sauer-Budge, Alexis F</creatorcontrib><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>PloS one</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Boardman, Anna K</au><au>Campbell, Jennifer</au><au>Wirz, Holger</au><au>Sharon, Andre</au><au>Sauer-Budge, Alexis F</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Rapid Microbial Sample Preparation from Blood Using a Novel Concentration Device: e0116837</atitle><jtitle>PloS one</jtitle><date>2015-02-01</date><risdate>2015</risdate><volume>10</volume><issue>2</issue><eissn>1932-6203</eissn><abstract>Appropriate care for bacteremic patients is dictated by the amount of time needed for an accurate diagnosis. However, the concentration of microbes in the blood is extremely low in these patients (1-100 CFU/mL), traditionally requiring growth (blood culture) or amplification (e.g., PCR) for detection. Current culture-based methods can take a minimum of two days, while faster methods like PCR require a sample free of inhibitors (i.e., blood components). Though commercial kits exist for the removal of blood from these samples, they typically capture only DNA, thereby necessitating the use of blood culture for antimicrobial testing. Here, we report a novel, scaled-up sample preparation protocol carried out in a new microbial concentration device. The process can efficiently lyse 10 mL of bacteremic blood while maintaining the microorganisms' viability, giving a 30- mu L final output volume. A suite of six microorganisms (Staphylococcus aureus, Streptococcus pneumoniae, Escherichia coli, Haemophilus influenzae, Pseudomonas aeruginosa, and Candida albicans) at a range of clinically relevant concentrations was tested. All of the microorganisms had recoveries greater than 55% at the highest tested concentration of 100 CFU/mL, with three of them having over 70% recovery. At the lowest tested concentration of 3 CFU/mL, two microorganisms had recoveries of ca. 40-50% while the other four gave recoveries greater than 70%. Using a Taqman assay for methicillin-sensitive S. aureus (MSSA)to prove the feasibility of downstream analysis, we show that our microbial pellets are clean enough for PCR amplification. PCR testing of 56 spiked-positive and negative samples gave a specificity of 0.97 and a sensitivity of 0.96, showing that our sample preparation protocol holds great promise for the rapid diagnosis of bacteremia directly from a primary sample.</abstract><doi>10.1371/journal.pone.0116837</doi></addata></record>
fulltext fulltext
identifier EISSN: 1932-6203
ispartof PloS one, 2015-02, Vol.10 (2)
issn 1932-6203
language eng
recordid cdi_proquest_miscellaneous_1694979620
source Open Access: PubMed Central; Publicly Available Content Database
subjects Candida albicans
Escherichia coli
Haemophilus influenzae
Pseudomonas aeruginosa
Staphylococcus aureus
Streptococcus pneumoniae
title Rapid Microbial Sample Preparation from Blood Using a Novel Concentration Device: e0116837
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T05%3A31%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Rapid%20Microbial%20Sample%20Preparation%20from%20Blood%20Using%20a%20Novel%20Concentration%20Device:%20e0116837&rft.jtitle=PloS%20one&rft.au=Boardman,%20Anna%20K&rft.date=2015-02-01&rft.volume=10&rft.issue=2&rft.eissn=1932-6203&rft_id=info:doi/10.1371/journal.pone.0116837&rft_dat=%3Cproquest%3E1694979620%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-proquest_miscellaneous_16949796203%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1694979620&rft_id=info:pmid/&rfr_iscdi=true