Pilot plant for flue gas treatment-continuous operation tests

Tests of continous operation have been performed on pilot plant at EPS Kawęczyn in the wide range of SO2 concentration (500–3000 ppm).The bag filter has been applied for aerosol separation. The high efficiences of SO2 and NOX removal, approximately 90% were obtained and influenced by such process pa...

Full description

Saved in:
Bibliographic Details
Published in:Radiation physics and chemistry (Oxford, England : 1993) England : 1993), 1995-09, Vol.46 (4-6), p.1067-1070
Main Authors: Chmielewski, A.G., Tymiński, B., Licki, J., Iller, E., Zimek, Z., Radzio, B.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Tests of continous operation have been performed on pilot plant at EPS Kawęczyn in the wide range of SO2 concentration (500–3000 ppm).The bag filter has been applied for aerosol separation. The high efficiences of SO2 and NOX removal, approximately 90% were obtained and influenced by such process parameters as: dose, gas temperature and ammonia stoichiometry. The main apparatus of the pilot plant (e.g. both accelerators) have proved their reliability in hard industrial conditions.