Loading…
Synchronization system for Gamma-4 electrophysical facility
A synchronization system for the Gamma-4 four-module electrophysical facility has been developed. It has been shown that the synchronization system should provide triggering (with precision not worse than ±3 ns) of the high-voltage gas-filled trigatron-type switches of the facility modules (144 spar...
Saved in:
Published in: | Journal of applied mechanics and technical physics 2015-01, Vol.56 (1), p.72-76 |
---|---|
Main Authors: | , , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A synchronization system for the Gamma-4 four-module electrophysical facility has been developed. It has been shown that the synchronization system should provide triggering (with precision not worse than ±3 ns) of the high-voltage gas-filled trigatron-type switches of the facility modules (144 spark gaps with an operating voltage of 1 MV), the pre-pulse switches of the modules (24 spark gaps with an operating voltage of 3 MV) and eight Arkad’ev-Marx generators (40 spark gaps with an operating voltage of 100 kV). |
---|---|
ISSN: | 0021-8944 1573-8620 |
DOI: | 10.1134/S0021894415010125 |