Loading…
Evaluation of the radiation parameters of the Gamma-4 electrophysical facility
This paper presents the results of measurements of the generation parameters of the Gamma-4 electrophysical facility designed to generate high-power bremsstrahlung pulses with a duration of ≈50 ns. Five shots of the Gamma-1 accelerator were performed, in which the bremsstrahlung exposure dose was me...
Saved in:
Published in: | Journal of applied mechanics and technical physics 2015-01, Vol.56 (1), p.67-71 |
---|---|
Main Authors: | , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This paper presents the results of measurements of the generation parameters of the Gamma-4 electrophysical facility designed to generate high-power bremsstrahlung pulses with a duration of ≈50 ns. Five shots of the Gamma-1 accelerator were performed, in which the bremsstrahlung exposure dose was measured at a distance of 20, 30, and 60 cm from the accelerator target. It is shown that the experimental data correspond to the radiation field of a point cosine source with a relative error of 13%. The spatial distribution of the bremsstrahlung exposure dose of the Gamma-4 facility was reconstructed taking into account the spatial orientation of the irradiators. The bremsstrahlung exposure doses at a distance of 15 cm from the modules targets are presented. |
---|---|
ISSN: | 0021-8944 1573-8620 |
DOI: | 10.1134/S0021894415010113 |